National Association of Testing Authorities, Australia
Scope of Accreditation
National Measurement Institute (NMI)
Site
Measurement Standards Unit, Brisbane
Accreditation No.
1
Site No.
13207
Date of Accreditation
19 Nov 1997
Contact
Availability
Services conditionally available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensional metrology - Engineering equipment and precision instruments | Electronic calipers; Vernier calipers | Length measurements | Comparison with a reference standard | In-house method NTM 14.3.7 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including dial calipersWith Calibration and Measurement Capability of - 0.02 mm from 0 mm to 300 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Steel rulers and measuring tapes | Length measurements | Direct measurement against a reference standard | BS 4372 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Steel rules only With Calibration and Measurement Capability of - 0.015 mm from 1 mm up to 1 m; 2 in 105 or 0.05 mm (whichever is greater) above 1 m up to 3 m | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensional metrology - Length and angle standards | Precision graticules | Length measurements | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Glass scales up to 20 mm With Calibration and Measurement Capability of- 4 μm from 0.1 mm up to 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mass - Determination of mass and calibration of weighing devices | Gaming accessories | Mass | Gravimetric measurement against reference mass | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 2 in 105 from 1 mg up to 5 000 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Industrial mass standards | Mass | Gravimetric measurement against reference mass | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 1 in 105 or 100 μg (whichever is greater) from 1 mg up to 5000 kg on-site calibrations 3 in 105 from 100 g up to 2 kg 5 in 106 from 5 kg up to 10 kg 1.5 in 105 from above 10 kg up to 50 kg 5 in 105 from 500 kg up to 5 000 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mass standards | Mass | Gravimetric measurement against reference mass | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 3 μg from 1 mg up to 10 mg; 5 μg above 10 mg up to 200 mg; 2 in 106 or 10 μg (whichever is greater) above 200 mg up to 20 g; 1 in 106 above 20 g up to 25 kg; 5 in 106 above 25 kg up to 1000 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Industrial volumetric equipment and bulk storage | Standard measures - > 25 L | Volume | Gravimetric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.007% from 2 L up to 1000 L | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Industrial volumetric equipment and bulk storageIncluding onsite calibrations | Bulk storage tanks; Industrial volumetric proving measures | Volume | Gravimetric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 0.01% from 1 L up to 5000 L On-site calibration of proving tanks by standard measures or by gravimetric methods | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Laboratory volumetric glassware and measures | Standard measures - < 50 L; Volumetric glassware and measures | Volume | Gravimetric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 0.002 mL at 1 mL; 1 in 104 or 0.004 mL (whichever is greater) above 1 mL up to 2 L |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
1
Site No.
13207
Print date