National Association of Testing Authorities, Australia
Scope of Accreditation
Proofload Pty Ltd
Site
Mechanical and NDT
Accreditation No.
19240
Site No.
21858
Date of Accreditation
01 Jun 2017
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of load generating lifting appliances | Serial and lever hoists | Operational load | Not applicable | AS 1418.2 | Serial hoists (limited to testing against dead weights) 2 to 2500 kN including testing in the field |
Evaluation of load handling, rigging and tensioning systems | Anchorages and supports for industrial fall arrest systems; Anchors and anchor plate assemblies; Padeyes | Proof load | Not applicable | AS/NZS 1891.4 Section 3.1.2 | 2 to 2500 kN including testing in the field |
C-hooks | Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | |
Chain | Breaking load; Proof load | Not applicable | AS 2321 | 2 to 2500 kN including testing in the field | |
Chain and lever blocks | Proof load | Not applicable | AS 1418.2 | 2 to 2500 kN including testing in the field | |
Chain slings | Breaking load; Proof load | Not applicable | AS 3775.1 | 2 to 2500 kN including testing in the field | |
Containers | Proof load | Not applicable | AS EN 12079.1, DNV 2.7-1 Section 4.6.3.2, Marine Orders 32, Woodside Engineering Standard Lifting Equipment W1000SG8676422 | 2 to 2500 kN including testing in the field | |
Eye bolts | Breaking load; Proof load | Not applicable | AS 2317.1 | 2 to 2500 kN including testing in the field | |
Eye hooks; Shank hooks | Breaking load; Proof load | Not applicable | AS 3777 | 2 to 2500 kN including testing in the field | |
Fibre rope | Breaking load; Proof load | Not applicable | AS 1380.1:1998 | 2 to 2500 kN including testing in the field | |
Fibre rope slings | Breaking load; Proof load | Not applicable | AS 1380.1:1998 | 2 to 2500 kN including testing in the field | |
Gripping devices; Plate clamps | Breaking load; Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | |
Ladle handling equipment | Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | |
Lifting and spreader beams | Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | |
Breaking load; Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | ||
Lifting clutches for concrete elements | Breaking load; Proof load | Not applicable | AS 3850.1 clause 2.6 | 2 to 2500 kN including testing in the field | |
Lifting rings and links | Breaking load; Proof load | Not applicable | AS 3776 | 2 to 2500 kN including testing in the field | |
Rigging screws and turnbuckles | Breaking load; Proof load | Not applicable | AS 2319 | 2 to 2500 kN including testing in the field | |
Shackles | Breaking load; Proof load | Not applicable | AS 2741 | 2 to 2500 kN including testing in the field | |
Sheave blocks | Breaking load; Proof load | Not applicable | AS 2089 | 2 to 2500 kN including testing in the field | |
Swivels | Breaking load; Proof load | Not applicable | AS 2318 | 2 to 2500 kN including testing in the field | |
Synthetic fibre roundslings | Breaking load; Proof load | Not applicable | AS 4497 | 2 to 2500 kN including testing in the field | |
Synthetic webbing flat slings | Breaking load; Proof load | Not applicable | AS 1353.1 | 2 to 2500 kN including testing in the field | |
Thimbles for wire rope | Breaking load; Proof load | Not applicable | AS 1138 | 2 to 2500 kN including testing in the field | |
Vacuum lifting devices | Proof load | Not applicable | AS 4991 | 2 to 2500 kN including testing in the field | |
Wedge type sockets | Breaking load; Proof load | Not applicable | AS 2740 | 2 to 2500 kN including testing in the field | |
Wire rope | Breaking load | Not applicable | AS 3569 | 2 to 2500 kN including testing in the field | |
Wire rope slings | Breaking load; Proof load | Not applicable | AS 1666.1 | 2 to 2500 kN including testing in the field | |
Non-destructive testing (NDT) - Electromagnetic testing | Coatings | Coating thickness | High frequency eddy current | ||
Metallic surfaces | Defect detection and characterisation | High frequency eddy current | |||
Non-destructive testing (NDT) - Magnetic particle testing | Metallic surfaces - Magnetic | Defect detection and characterisation | AC magnetic flow | ||
Non-destructive testing (NDT) - Penetrant testing | Metallic surfaces | Defect detection and characterisation | Solvent removable; Water washable |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
19240
Site No.
21858
Print date
08 Dec 2024