Bureau Veritas Asset Integrity and Reliability Services Pty Limited

Site

Melbourne Laboratory

Accreditation No.

1267

Site No.

20677

Date of Accreditation

18 Jun 2012

Address

3/435 Williamstown Road
Port Melbourne, VIC 3207
Australia

bureauveritas.com.au

Contact

Mr Weichen Sun P: +61 (03) 99220838

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Speed and velocity - Verification of fixed speed detector installationsincluding on site calibrations Inductive loop speed measurement systems Field measurement of inductance Direct electrical measurement

Capability

with a Calibration and Measurement Capability of -
6.3% of reading + 1.6 μH at 1 kHz from 20 μH to 500 μH

Inductive loop speed measurement systems; Piezoelectric speed measurement systems Field measurement of DC resistance Direct electrical measurement

Capability

with a Calibration and Measurement Capability of - 

Inductive Loop In-Road Sensors

0.4% of reading + 0.02 Ω from 0.5 Ω to 30 Ω
2% of reading from 30 kΩ to 3 MΩ
5% of reading from 3 MΩ to 100 MΩ
17% of reading from 100 MΩ to 300 MΩ,

Piezo In-Road Sensors
2% of reading from 30 kΩ to 3 MΩ
5% of reading from 3 MΩ to 100 MΩ
17% of reading from 100 MΩ to 300 MΩ

Field measurement of insulation resistance Direct electrical measurement

Capability

with a Calibration and Measurement Capability of -
10% reading from 2 MΩ to 500 MΩ at 500 V

Piezoelectric speed measurement systems Field measurement of voltage Direct electrical measurement

Capability

with a Calibration and Measurement Capability of -
DC Voltage
0.07% of reading +35 μV from 0 mV to 30 mV
1% of reading from 30 mV to 3000 mV
Waveform Voltage
2.4% of reading + 40 mV on 200 mV/Div
2.4% of reading + 100 mV on 500 mV/Div
2.4% of reading + 200 mV on 1 V/Div

Field measurement of capacitance Direct electrical measurement

Capability

with a Calibration and Measurement Capability of -
3 % of reading from 2 nF to 200 nF at 1 Hz

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.