EMC Technologies Pty Ltd

Site

Melbourne Laboratory – EMC Test Laboratory

Accreditation No.

5292

Site No.

5285

Date of Accreditation

28 Apr 1994

Address

176 Harrick Road
Keilor Park, VIC 3042
Australia

emctech.com.au

Contact

Mr Shabbir Ahmed P: +61 (03) 93651000

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure
Assessment of emissions and immunity - EMC emission standards Aerospace and military grade equipment Conducted emissions; Conducted interference; Discontinuous disturbances; Disturbance power; Radiated interference Not applicable

MIL-STD-461 B/C: CE01 - 0 to 15 kHz;

MIL-STD-461 B/C: CE03 - 0.015 MHz to 50 MHz;

Radiated emissions Not applicable MIL-STD-461 B/C: RE01;
MIL-STD-461 B/C: RE02;
MIL-STD-461 D/E/F/G: RE101;
MIL-STD-461 D/E/F/G: RE102;
Airborne equipment Conducted interference; Radiated interference Not applicable

RTCA DO160 F/G section 21 

Electrical and electronic products; Power tools - Electric Conducted emissions; Conducted interference; Discontinuous disturbances; Disturbance power; Radiated interference Not applicable

AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; CNS 13783-1;

AS/NZS CISPR 32 ED 2.0; CISPR 32 ED 2.0; EN 55032;

AS/NZS 4251.1; AS/NZS 61000.6.3; IEC 61000-6-3; EN 61000-6-3

FCC part 18 requirements and MP-5 for intentional emitters up to 18 GHz; 

FCC part 15 requirements; ANSI C63.4:2014;  ANSI C63.10:2013;  KDB publications and ISED (formerly Industry Canada) ICES-003;

Unintentional radiators described in FCC part 15, subpart B using ANSI C63.4-2014; 

Intentional radiators described in FCC part 15, subpart C using ANSI C63.10-2013; 

Intentional  radiators described in FCC part 15, subpart E for U-NII devices without DFS using ANSI C63.10:2013; 

FCC KDB guidelines: KDB 789033 D02; KDB 558074 D01;

RSS-210;
RSS-247;
RSS-GEN
Electrical equipment for measurement, control and laboratory use Conducted emissions; Conducted interference; Radiated interference Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;

IEC 61326-1; EN 61326-1

Electrical lighting and similar equipment Conducted emissions; Conducted interference; Radiated emissions; Radiated interference Not applicable

AS/NZS CISPR 15; CISPR 15; EN 55015 

Information technology equipment Conducted emissions; Conducted interference; Conducted telecommunications port emissions; Radiated interference AMN and voltage probe; ISN and current clamp

Excluding capacitive voltage probe tests for telecommunications ports AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; VCCI; CNS 13438; EN 55022

Machine tools Conducted emissions; Conducted interference; Discontinuous disturbances; Mains harmonics and flicker; Radiated emissions; Radiated interference Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; 

AS/NZS 61000.6.4; IEC 61000-6-4; EN 61000-6-4;

IEC 61000-3-2; IEC 61000-3-3

Maritime navigation equipment Conducted emissions; Conducted interference; Radiated interference Not applicable

EN 60945

Medical electrical equipment Conducted interference; Radiated interference Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;

AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2

Power leads Conducted interference; Radiated interference Not applicable

MIL-STD-461 D/E/F/G: CE101 (30 Hz to 10 kHz);

MIL-STD-461 D/E/F/G: CE102 (10 kHz to 10 MHz)

Radio equipment Conducted emissions; Conducted interference; Radiated interference Not applicable

ETSI EN 301 489-1  

Railway vehicles and equipment including railway signalling and telecommunications equipment Conducted interference; Radiated interference Not applicable

EN 50121-2; EN 50121-3-1; EN 50121-3-2; EN 50121-4; EN 50121-5

Shielded enclosures Attenuation performance Not applicable

MIL-STD-285 Rev. 1.8

Sound and television broadcast receivers and associated equipment Conducted interference; Disturbance power; Radiated interference Not applicable

AS/NZS CISPR 13; CISPR 13; EN 55013; CNS 13439 

Telecommunication network equipment Conducted emissions; Conducted interference; Radiated interference Not applicable

ETSI EN 300 386

Vehicles, boats and internal combustion engine driven equipment Conducted interference; Radiated interference Not applicable

AS/NZS CISPR 25; CISPR 25; EN 55025;

AS/NZS CISPR 12; CISPR 12; EN 55012;

ISO 7637-2; ISO 7637-3;

UN Regulation No. 10 (E/ECE/324/Add.9) : Clauses 6.5, 6.6, 6.7, 6.8 (free field testing method and bulk current injection - BCI method only), 6.9 only.
Assessment of emissions and immunity - EMC immunity standards Aerospace and military grade equipment Conducted disturbance; Radiated radio-frequency Bulk cable injection; Damped sinusoidal transients; Impulse excitation; Magnetic field

MIL-STD-461 B/C: RS01, RS02, RS03; 

MIL-STD-461 D/E/F/G: RS101, RS103 

MIL-STD-461 B/C: CS01, CS02 (except broadband susceptibility to Notice 3), CS06; 

MIL-STD-461 D/E/F/G: CS101, CS114, CS115, CS116, CS118; 

Airborne equipment Conducted disturbance; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Voltage spikes Not applicable

RTCA DO160 F/G Sections 15, 17, 18, 19, 20, 25;

Components of fire, intruder and social alarm systems Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 50130-4;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Electrical and electronic products; Power tools - Electric Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS CISPR 14.2; CISPR 14-2; EN 55014-2;

AS/NZS 61000.6.1; IEC 61000-6-1; EN 6000-6-1;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Electrical equipment for measurement, control and laboratory use Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

IEC 61326-1; EN 61326-1;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Electrical lighting and similar equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 61547;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Electricity meters and associated transformers Electrical fast transient; Radiated radio-frequency; Surge immunity Not applicable

NSC publication for Pattern Approval and Initial verification of electricity meters and associated transformers

Information technology equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS CISPR 24; CISPR 24; EN 55024;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Low voltage switchgear and control equipment Common mode low frequency; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 60947;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Machine tools Conducted disturbance; Electrical fast transient; Electrostatic discharge; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000-6-2; 

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Medical electrical equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Multimedia equipment Common mode low frequency; Conducted disturbance; Conducted susceptibility; DC input power ripple; Damped oscillatory wave; Electrical appliances and electronic products; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Induced signal susceptibility; Magnetic effects; Power frequency magnetic field; Power tools - Electric; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Voltage spikes Not applicable EN 55035 excluding clause 4.2.7;
AS/NZS CISPR 35 excluding clause 4.2.7; CISPR 35 excluding clause 4.2.7

Radio equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

ETSI EN 301 489-1;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Railway vehicles and equipment including railway signalling and telecommunications equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 50121-3-2; EN 50121-4; EN 51021-5

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Telecommunication network equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

ETSI EN 300 386;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessment Antennas; Electricity grid installations; High voltage transformer equipment; Microwave ovens Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields Not applicable

AS/NZS 2772.2 and EMC Technologies in-house TP EME ARPANSA for compliance with ARPANSA (RPS No.3) and NZS 2772.1;

EN 62311:2008;

EN 62233;

Canadian standard RSS-102 (RF) and RSS-102 (NS) - 3kHz to 10MHz
Hand held and wireless communication devices Specific absorption rate (SAR) Not applicable

ACMA Radiocommunications (Electromagnetic Radiation - Human exposure) Standard;

ARPANSA Radiation Protection Standard (RPS No.3);

NZS 2772.1;

EN 50566:2013; EN 50360:2001; EN 62311:2008; EN 62209-1:2006; EN 62209-2:2010; 

IEEE 1528; 

FCC - guidelines for human exposure to RF electromagnetic field:1997;

FCC KDB guidelines: 

KDB 865664 D01; KDB 865664 D02; KDB 447498; KDB 447498 D02; KDB 447498; KDB 643646 D01; KDB 248227 D01; KDB 941225 D01; KDB 941225 D05; KDB 941225 D05A; KDB 941225 D06; KDB 941225 D07; KDB 616217 D04; KDB 648474 D04; KDB 648474 D03; KDB 615223 D01;

Canadian Standard RSS-102 (SAR) including SPR-002 (NS)

Testing of gaming machines and gaming systems Interactive gaming; Land-based gaming; Wide area gaming systems Gaming equipment hardware testing; Gaming platform evaluation Electrical fast transient; Electrostatic interference; Voltage short dips and interruptions Australian Gaming Standard

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.