EMC Technologies Pty Ltd

Site

Melbourne Laboratory – EMC Test Laboratory

Accreditation No.

5292

Site No.

5285

Date of Accreditation

28 Apr 1994

Address

176 Harrick Road
Keilor Park, VIC 3042
Australia

emctech.com.au

Contact

Mr Shabbir Ahmed P: +61 (03) 93651000

Availability

Services available to external clients

Scope of Accreditation

Melbourne Laboratory – EMC Test Laboratory

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Electromagnetic compatibility (EMC) - Emissions - Commercial Airborne equipment Conducted emissions; Radiated emissions Not applicable

RTCA DO160 F/G section 21

Conducted RF emissions 150 kHz to 150 MHz 

Electrical and electronic products; Power tools - Electric Conducted emissions; Radiated emissions Not applicable

AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; CNS 13783-1;
AS/NZS CISPR 32; CISPR 32; EN 55032;
AS/NZS 4251.1; AS/NZS 61000.6.3; IEC 61000-6-3; EN 61000-6-3
FCC part 18 requirements and MP-5 for intentional emitters up to 18 GHz;
FCC part 15 requirements; ANSI C63.4:2014;  ANSI C63.10:2013;  KDB publications and ISED (formerly Industry Canada) ICES-003;
Unintentional radiators described in FCC part 15, subpart B using ANSI C63.4-2014;
Intentional radiators described in FCC part 15, subpart C using ANSI C63.10-2013;
Intentional  radiators described in FCC part 15, subpart E for U-NII devices without DFS using ANSI C63.10:2013;
FCC KDB guidelines: KDB 789033 D02; KDB 558074 D01;
RSS-210;
RSS-247;
RSS-248;
RSS-GEN

Radiated measurements performed in the
10 metre iOATS Semi Anechoic Chamber Room 12 - Test Site 1
3 metre iOATS Semi Anechoic Chamber Room 13 - Test Site 2

Electrical equipment for measurement, control and laboratory use Conducted emissions; Radiated emissions Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;
IEC 61326-1; EN 61326-1

Electrical lighting and similar equipment Conducted emissions; Radiated emissions Not applicable

AS/NZS CISPR 15; CISPR 15; EN 55015 

Information technology equipment Conducted emissions; Conducted telecommunications port emissions; Radiated emissions AMN and voltage probe; ISN and current clamp

Excluding capacitive voltage probe tests for telecommunications ports AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; VCCI; CNS 13438; EN 55022; AS/NZS CISPR 32; CISPR 32 and EN 55032

Machine tools Conducted emissions; Discontinuous disturbances; Mains harmonics and flicker; Radiated emissions Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;
AS/NZS 61000.6.4; IEC 61000-6-4; EN 61000-6-4;
IEC 61000-3-2; IEC 61000-3-3

Maritime navigation equipment Conducted emissions; Radiated emissions Not applicable

EN 60945

Excluding measurements below 2 kHz

Medical electrical equipment Radiated emissions Not applicable

AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;
AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2

Radio equipment Conducted emissions; Radiated emissions Not applicable

ETSI EN 301 489-1

Railway vehicles and equipment including railway signalling and telecommunications equipment Conducted emissions; Radiated emissions Not applicable

EN 50121-2; EN 50121-3-1; EN 50121-3-2; EN 50121-4; EN 50121-5

Sound and television broadcast receivers and associated equipment Conducted emissions; Radiated emissions Not applicable

AS/NZS CISPR 13; CISPR 13; EN 55013; CNS 13439

Telecommunication network equipment Conducted emissions; Radiated emissions Not applicable

ETSI EN 300 386

Vehicles, boats and internal combustion engine driven equipment Conducted emissions; Radiated emissions Not applicable

AS/NZS CISPR 25; CISPR 25; EN 55025;
AS/NZS CISPR 12; CISPR 12; EN 55012;
ISO 7637-2; ISO 7637-3;
UN Regulation No. 10 (E/ECE/324/Add.9) : Clauses 6.5, 6.6, 6.7, 6.8 (free field testing method and bulk current injection - BCI method only), 6.9 only.

Testing on components only

Electromagnetic compatibility (EMC) - Emissions - Military Aerospace and military grade equipment Radiated emissions Not applicable MIL-STD-461 B/C: RE01;
MIL-STD-461 B/C: RE02;
MIL-STD-461 D/E/F/G: RE101;
MIL-STD-461 D/E/F/G: RE102;
MIL-STD-461 B/C: RE01 - 30 Hz to 50 kHz
MIL-STD-461 B/C: RE02 - 14 kHz to 10 GHz
MIL-STD-461 D/E/F/G: RE101 - 30 Hz to 100 kHz
MIL-STD-461 D/E/F/G: RE102 - 10 kHz to 18 GHz
Conducted emissions Not applicable

MIL-STD-461 B/C: CE01 - 0 to 15 kHz;

MIL-STD-461 B/C: CE03 - 0.015 MHz to 50 MHz;

Power leads Conducted emissions Not applicable

MIL-STD-461 D/E/F/G: CE101 (30 Hz to 10 kHz);
MIL-STD-461 D/E/F/G: CE102 (10 kHz to 10 MHz)

Electromagnetic compatibility (EMC) - Immunity - Commercial Airborne equipment Conducted disturbance; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Voltage spikes Not applicable

RTCA DO160 F/G Sections 15, 17, 18, 19, 20, 25;

Components of fire, intruder and social alarm systems Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 50130-4;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Electrical and electronic products; Power tools - Electric Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS CISPR 14.2; CISPR 14-2; EN 55014-2;
AS/NZS 61000.6.1; IEC 61000-6-1; EN 6000-6-1;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Electrical equipment for measurement, control and laboratory use Common mode low frequency; Conducted disturbance; Conducted susceptibility; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

IIEC 61326-1; EN 61326-1;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Electrical lighting and similar equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable EN 61547;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

IEC 61000-4-18; EN 61000-4-18
Electricity meters and associated transformers Electrical fast transient; Radiated radio-frequency; Surge immunity Not applicable

NSC publication for Pattern Approval and Initial verification of electricity meters and associated transformers

Information technology equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS CISPR 24; CISPR 24; EN 55024;

ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;

AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4

IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;

AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;

AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;

AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;

IEC 61000-4-9; EN 61000-4-9;

IEC 61000-4-10; EN 61000-4-10;

AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11

IEC 61000-4-12;

AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 

AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;

 IEC 61000-4-18; EN 61000-4-18

Low voltage switchgear and control equipment Common mode low frequency; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 60947;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Machine tools Conducted disturbance; Electrical fast transient; Electrostatic discharge; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions Not applicable
Medical electrical equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Multimedia equipment Common mode low frequency; Conducted disturbance; Conducted susceptibility; DC input power ripple; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Induced signal susceptibility; Magnetic effects; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Voltage spikes Not applicable EN 55035 excluding clause 4.2.7;
AS/NZS CISPR 35 excluding clause 4.2.7; CISPR 35 excluding clause 4.2.7

Radio equipment Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

ETSI EN 301 489-1;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Railway vehicles and equipment including railway signalling and telecommunications equipment Common mode low frequency; Conducted disturbance; Conducted susceptibility; Damped oscillatory wave; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

EN 50121-3-2; EN 50121-4; EN 51021-5
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Telecommunication network equipment Common mode low frequency; Conducted disturbance; Conducted susceptibility; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage short dips and interruptions Not applicable

ETSI EN 300 386;
ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
IEC 61000-4-9; EN 61000-4-9;
IEC 61000-4-10; EN 61000-4-10;
AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
IEC 61000-4-12;
AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13;
AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
 IEC 61000-4-18; EN 61000-4-18

Electromagnetic compatibility (EMC) - Immunity - Military Aerospace and military grade equipment Conducted susceptibility; Radiated radio-frequency; Radiated susceptibility Bulk cable injection; Damped sinusoidal transients; Impulse excitation; Magnetic field

MIL-STD-461 B/C: RS01, RS02, RS03;
MIL-STD-461 D/E/F/G: RS101, RS103
MIL-STD-461 B/C: CS01, CS02 (except broadband susceptibility to Notice 3), CS06;
MIL-STD-461 D/E/F/G: CS101, CS114, CS115, CS116, CS118;

MIL-STD-461 B/C RS01: 30 Hz to 50 kHz;

MIL-STD-461 B/C RS03: 14 kHz to 18 GHz ;

MIL-STD-461 D/E/F/G RS101: 30 Hz to 100 kHz;

MIL-STD-461 D/E/F/G RS103: 2 MHz to 18 GHz;

MIL-STD-461 B/C CS01: 30 Hz to 50 kHz;

MIL-STD-461 B/C CS02: 0.5 MHz to 400 MHz;

MIL-STD-461 D/E/F/G CS101: 30 Hz to 150 kHz;

MIL-STD-461 D/E/F/G CS114: 10 kHz to 400 MHz;
Electromagnetic radiation exposure - Extremely low frequency (ELF) fields Electricity grid installations; High voltage transformer equipment Broadband measurements of H-fields; Narrowband measurements of H-fields Not applicable

AS/NZS 2772.2 and ARPANSA Radiation Protection (RPS S-1) and NZS 2772.1;
EN 62311;
EN 62233;
EN 50500;
IEC 62597;
Canadian standard RSS-102 (RF) MEAS and RSS-102 (NS) MEAS – Issue 5 : 2015 (3kHz to 10MHz)
ICNIRP Guidelines
LF Guidelines 2010 (1 Hz – 100 kHz);
Static Magnetic Fields – Guidelines 2009;
RF EMF Guidelines 2020 (100 kHz – 300 GHz);

Broadband measurements of E-fields in the range 100 kHz to 45.5 GHz;

Broadband measurements of H-fields in the range 100 kHz to 1 GHz;

Narrowband measurements of E-fields in the range 9 kHz to 40 GHz;

Narrowband measurements of H-fields in the range 9 kHz to 300 MHz

Electromagnetic radiation exposure - Radiofrequency (RF) fields Antennas; Microwave ovens Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields Not applicable

AS/NZS 2772.2 and ARPANSA Radiation Protection (RPS S-1) and NZS 2772.1;
EN 62311;
EN 62233;
EN 50500;
IEC 62597;
Canadian standard RSS-102 (RF) MEAS and RSS-102 (NS) MEAS – Issue 5 : 2015 (3kHz to 10MHz)
ICNIRP Guidelines
LF Guidelines 2010 (1 Hz – 100 kHz);
Static Magnetic Fields – Guidelines 2009;
RF EMF Guidelines 2020 (100 kHz – 300 GHz);

Broadband measurements of E-fields in the range 100 kHz to 45.5 GHz;
Broadband measurements of H-fields in the range 100 kHz to 1 GHz;
Narrowband measurements of E-fields in the range 9 kHz to 40 GHz;
Narrowband measurements of H-fields in the range 9 kHz to 300 MHz

Shielded enclosures Attenuation performance Not applicable

MIL-STD-285 Rev. 1.8

Testing of gaming machines and gaming systems Interactive gaming; Land-based gaming; Wide area gaming systems Gaming equipment hardware testing; Gaming platform evaluation Electrical fast transient; Electrostatic interference; Voltage short dips and interruptions Australian Gaming Standard

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.