Mobile Test 'n' Cal Australia Pty Ltd

Site

Mobile Test ‘n’ Cal

Accreditation No.

20282

Site No.

24177

Date of Accreditation

07 Dec 2018

Address

11 River Road
Dinmore, QLD 4303
Australia

mobiletestncal.com.au

Contact

Mr Jeremy White P: +61 (07) 32820007

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM) AC current; DC current Comparison with a reference standard

Capability

With Calibration and Measurement Capability of -


D.C. current
 0.01 % + 30 nA from 0 to 200 μA,
 0.0009 % + 40 nA from 200 μA to 2 mA,
 0.007 % + 0.3 μA from 2 mA to 20 mA,
 0.008 % + 3 μA from 20 mA to 200 mA,
 0.014 % + 35 μA from 200 mA to 2 A,
0.032 % + 0.35 mA from 2 A to 10 A


A.C. current
 0.10% + 0.25 μA from 25 μA to 100 μA and from 45 Hz to 1 kHz,
 0.09% + 0.5 μA from 100 μA to 1 mA and from 45 Hz to 1 kHz,
 0.08% + 4 μA from 1 mA to 10 mA and from 45 Hz to 1 kHz,
 0.09% + 40 μA from 10 mA to 100 mA and from 45 Hz to 1 kHz,
 0.10% + 400 uA from 100 mA to 1 A and from 45 Hz to 1 kHz,
 0.06% + 2 mA from 1 A to 10 A and from 45 Hz to 100 Hz,


1.30% + 0.25 μA from 25 μA to 100 μA and from 1 kHz to 2 kHz,

0.70% + 0.7 μA from 100 μA to 1 mA and from 1 kHz to 2 kHz,

0.46 % + 7 μA from 1 mA to 10 mA and from 1 kHz to 2 kHz,
 0.46 % + 70 μA from 10 mA to 100 mA and from 1 kHz to 2 kHz,
 0.60% + 700 μA from 100 mA to 1 A and from 1 kHz to 2 kHz,
 0.30 % + 4 mA from 1 A to 10 A and from 100 Hz to 1 kHz,


Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard

Capability

With Calibration and Measurement Capability of - 

7 mμ at 100 mμ, 1 μ, 10 μ

0.011 μ at 100 μ

0.083 μ at 1 kμ

0.82 μ at 10 kμ

0.004 kμ at 100 kμ

0.00015 Mμ at 1 Mμ

0.0039 Mμ at 10 Mμ

0.52 Mμ at 100 Mμ

Digital multimeters (DMM); Voltmeters AC voltage; DC voltage Comparison with a reference standard

Capability

With Calibration and Measurement Capability of -

DC Voltage

0.004 % + 3 μV from 0 to 200 mV
 0.003 % + 4 μV from 200 mV to 2 V
 0.003 % + 40 μV from 2 V to 20 V
 0.003 % + 0.4 mV from 20 V to 200 V
 0.003 % + 4 mV from 200 V to 1000 V


AC Voltage

0.032 % + 20 μV from 20 mV to 200 mV and from 45 Hz to 1 kHz,

 0.033 % + 90 μV from 200 mV to 2 V and from 45 Hz to 1 kHz,
 0.031 % + 1 mV from 2 V to 20 V and from 45 Hz to 1 kHz,
 0.035 % + 8 mV from 20 V to 200 V and from 45 Hz to 1 kHz,
 0.036 % + 75 mV from 200 V to 700 V and from 45 Hz to 1 kHz.


 0.07 % + 35 μV from 20 mV to 200 mV and from 1 kHz to 20 kHz,
 0.06 % + 135 μV from 200 mV to 2 V and from 1 kHz to 20 kHz,
 0.05 % + 2 mV from 2 V to 20 V and from 1 kHz to 20 kHz.
 0.09 % + 40 mV from 20 V to 200 V and from 1 kHz to 20 kHz,

0.13 % + 400 mV from 200 V to 700 V and from 1 kHz to 10 kHz.

 0.3 % + 70 μV from 20 mV to 200 mV and from 20 kHz to 100 kHz,
 0.22 % + 2 mV from 200 mV to 2 V and from 20 kHz to 100 kHz.
 0.18 % + 33 mV from 2 V to 20 V and from 20 kHz to 100 kHz.



The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.