Mobile Test 'n' Cal Australia Pty Ltd

Site

Mobile Test ‘n’ Cal

Accreditation No.

20282

Site No.

24177

Date of Accreditation

07 Dec 2018

Address

28 Staple Street
Seventeen Mile Rocks, QLD 4073
Australia

mobiletestncal.com.au

Contact

Mr Anthony Wynn P: +61 1800256838

Availability

Services available to external clients

Scope of Accreditation

Mobile Test ‘n’ Cal

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM) AC current; DC current Comparison with a reference standard

Capability

With Calibration and Measurement Capability of -


D.C. current

100 μA/A + 30 nA    from 0 to 200 μA
90 μA/A + 40 nA      above 200 μA to 2 mA
70 μA/A +0.3 μA      above 2 mA to 20 mA
80 μA/A + 3 μA        above 20 mA to 200 mA
150 μA/A + 35 μA     above 200 mA to 2 A
400 μA/A + 0.4 mA  above 2 A to 10 A

A.C. current

3 mA/A + 0.1 μA      from 25 μA to 100 μA and       from 45 Hz to 1 kHz
13 mA/A + 0.3 μA    from 25 μA to 100 μA and       from 1 kHz to 2 kHz                          
0.9 mA/A + 0.5 μA   above 100 μA to 1 mA and      from 45 Hz to 1 kHz
7.0 mA/A + 0.7 μA   above 100 μA to 1 mA and      from 1 kHz to 2 kHz                              
0.8 mA/A + 4 μA      above 1 mA to 10 mA and      from 45 Hz to 1 kHz
4.6 mA/A + 70 μA    above 1 mA to 10 mA and      from 1 kHz to 2 kHz                              
0.9 mA/A + 30 μA    above 10 mA to 100 mA and  from 45 Hz to 1 kHz
4.6 mA/A + 70 μA   above 10 mA to 100 mA and  from 1 kHz to 2 kHz                              
1.0 mA/A + 0.4 mA  above 100 mA to 1 A and        from 45 Hz to 1 kHz
6.0 mA/A + 0.7 mA  above 100 mA to 1 A and        from 1 kHz to 2 kHz                              
9.1 mA/A + 2mA     above 1 A to 10 A and             from 45 Hz to 1 kHz
Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard

Capability

With Calibration and Measurement Capability of - 

7 mΩ/Ω at 1 Ω
700 μΩ/Ω at 10 Ω
110 μΩ/Ω at 100 Ω
83 μΩ/Ω at 1 kΩ
82 μΩ/Ω at 10 kΩ
40 μΩ/Ω at 100 kΩ
150 μΩ/Ω at 1 MΩ
400 μΩ/Ω at 10 MΩ                                    
5.7 mΩ/Ω at 100 MΩ
Digital multimeters (DMM); Voltmeters AC voltage; DC voltage Comparison with a reference standard

Capability

With Calibration and Measurement Capability of -

DC Voltage

40 μV/V + 3 μV   from 0 to 200 mV
30 μV/V + 4 μV above 200 mV to 2 V
30 μV/V + 40 μV above 2 V to 20 V
30 μV/V + 0.5 mV above 20 V to 200 V
30 μV/V + 4 mV above 200 V to 1000 V


AC Voltage

320 μV/V + 20 μV    from 20 mV to 200 mV and     45 Hz to 1 kHz
700 μV/V + 35 μV    from 20 mV to 200 mV and     1 kHz to 20 kHz
3.0 mV/V + 70 μV    from 20 mV to 200 mV and     20 kHz to 100 kHz
330 μV/V + 90 μV    above 200 mV to 2 V and        45 Hz to 1 kHz
600 μV/V + 135 μV above 200 mV to 2 V and        1 kHz to 20 kHz
2.2 mV/V + 2 mV     above 200 mV to 2 V and        20 kHz to 100 kHz
310 μV/V + 1 mV     above 2 V to 20 V and             45 Hz to 1 kHz
640 μV/V + 2 mV     above 2 V to 20 V and             1 kHz to 20 kHz
2.2 mV/V + 2 mV     from 2 V to 20 V and               20 kHz to 100 kHz
1.1 mV/V + 7.5 mV  above 20 V to 200 V and         45 Hz to 1 kHz
900 μV/V + 40 mV   above 20 V to 200 V and         1 kHz to 20 kHz
1.1 mV/V + 7.5 mV  above 200 V to 700 V and       45 Hz to 1 kHz
1.3 mV/V + 400 μV above 200 V to 700 V and       1 kHz to 10 kHz


The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.