Australian On-site Services Pty Ltd

Site

Mobile Unit

Accreditation No.

19880

Site No.

23240

Date of Accreditation

22 Aug 2016

Address

264 Guthridge Pde
Sale, VIC 3850
Australia

Contact

Mr Justin van Putten P: +61 0409423119

Availability

Type C Inspection Body

Scope of Accreditation

Mobile Unit

ISO/IEC 17020 (2012)

Infrastructure and Asset Integrity

Service Product Determinant Procedure Limitations
Evaluation of height safety equipment and systems Harnesses; Inertia reels; Lanyards; Terminators and terminal fittings In-service inspection Covering standards, codes and specifications addressing the service, including AS/NZS 1891.1, AS/NZS 1891.2, AS/NZS 1891.3, AS/NZS 1891.4, in-house procedures and client specifications.
Evaluation of load generating lifting appliances Lifting devices In-service inspection; Testing

Covering standards, codes and specifications addressing the service, including AS 1418.1, AS1418.2, AS 1666.2, AS 2089, AS 3775.2 , AS 4991, in-house procedures and client specifications.

Lifting devices limited to lever hoists, chain blocks, sheave blocks, snatch blocks, winches, lifting beams, lifting frames and spreader beams, beam and girder clamps

Including functional load testing up to working load limit (in the range of 1 kN to 200 kN) 

Evaluation of load handling, rigging and tensioning systems Rigging In-service inspection

Covering standards, codes and specifications addressing the service, including AS 1353.1, AS 1353.2, AS 1666.1, AS 1666.2, AS 2759, AS 3775.1, AS 3775.2, AS4497, in-house procedures and client specifications.

Including chain, chain slings, flat and round webbing slings, wire rope slings and braided rope slings
Rigging components In-service inspection Covering standards, codes and specifications addressing the service, including AS 2317.1, AS 2318,  AS 2319, AS 2741, AS 3775.1, AS 3775.2, AS 3776, AS 3777, AS 4991, in-house procedures and client specifications. Including rigging screws, turnbuckles, eyebolts, shackles, plate clamps, swivels, hooks, links and terminal devices and attachments

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.