National Association of Testing Authorities, Australia
Scope of Accreditation
Tex@Site Pty Ltd
Site
NATA Laboratory
Accreditation No.
15281
Site No.
15902
Date of Accreditation
16 Jul 2007
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical instrument calibrators | Instrument calibrators | Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 20 μΩ/Ω + 5 μΩ up to 2 Ω; 14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 12 μΩ/Ω + 51 mΩ above 2 kΩ to 20 kΩ; 16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 170 μΩ/Ω + 19 kΩ above 20 MΩ to 200 MΩ; 0.15% reading+ 2.6 MΩ above 200 MΩ to 2 GΩ; 0.35% reading+ 47 MΩ above 2 GΩ to 20 GΩ; 0.75% reading+ 0.056%/GΩ above 20 GΩ to 90 GΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC voltage | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 300 μV/V + 4.6 μV up to 200 mV and from 40 Hz to 100 Hz;260 μV/V + 440 μV above 200 mV to 2 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV above 2 V to 20 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV above 20 V to 200 V and from 40 Hz to 100 Hz; 260 μV/V + 140 mV above 200 V to 1000 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV up to 200 mV and above 100 Hz to 2 kHz; 240 μV/V + 420 μV above 200 mV to 2 V and above 100 Hz to 2 kHZ; 200 μV/V + 400 μV above2 V to 20 V and above 100 Hz to 2 kHz; 230 μV/V + 380 μV above 20 V to 200 V and above 100 Hz to 2 kHz; 260 μV/V + 140 mV above 200 V to 1000 V and above 100 Hz to 2 kHz; 400 μV/V + 24 μV up to 200 mV and above 2 kHz to 10 kHz; 260 μV/V + 380 μV above 200 mV to 2 V and above 2 kHz to 10 kHz; 220 μV/V + 1.6 mV above 2 V to 20 V and above 2 kHZ to 10 kHZ; 220 μV/V + 16 mV above 20 V to 200 V and above 2 kHz to 10 kHz; 260 μV/V + 140 mV above 200 V to 1000 V and above 2 kHz to 10 kHz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC current | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 780 μA/A + 68 nA from 30 μA to 200 μA and from 10 Hz to 10 kHz;460 μA/A + 470 nA above 200 μA to 2 mA and from 10 Hz to 10 kHz; 460 μA/A + 4.7 μA above 2 mA to 20 mA and from 10 Hz to 10 kHz; 690 μA/A + 47 μA above 20 mA to 200 mA and above 10 Hz to 10 kHz; 0.11% reading + 1.1mA above 200 mA to 2 A and above 10 Hz to 2 kHz; 0.13% reading + 8.2mA above 2 A to 20 A and above 10 Hz to 2 kHz; 0.13% reading + 1.1 mA above 200 mA to 2 A and above 2 kHz to 10 kHz; 0.36% reading + 13 mA above 2 A to 20 A and above 2 kHz to 10 kHz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC current | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 30 μA/A +11 nA up to 200 μA;30 μA/A + 70 nA above 200 μA to 2 mA; 40 μA/A + 700 nA above 2 mA to 20 mA; 100 μA/A + 20 μA above 20 mA to 200 mA; 390 μA/A + 530 μA above 200 mA to 2 A; 0.11% reading + 3.9 mA above 2 A to 20 A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC voltage | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 17 μV/V + 6.3 μV up to 200 mV; 15 μV/V + 1.5 mV above 20 V to 200 V; | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Current clamps; Digital multimeters (DMM) | AC current | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - In the laboratory 710 μA/A + 69 nA up to 200 μA and from 20 Hz to 1 kHz; 450 μA/A + 480 nA above 200 μA to 2 mA and from 20 Hz to 1 kHz; 450 μA/A + 4.8 μA above 2 mA to 20 mA and from 20 Hz to 1 kHz; 680 μA/A + 48 μA above 20 mA to 200 mA and from 20 Hz to 1 kHz; 0.21% reading + 1.1 mA above 200 mA to 2 A and from 20 Hz to 500 Hz; 0.22% reading + 8.3 mA above 2 A to 20 A and from 20 Hz to 500 Hz For on site calibrations 0.18% reading + 550 nA from 20 μA to 200 μA and at 57 Hz; 0.12% reading + 1.6 μA above 200 μA to 2 mA and at 57 Hz; 0.12% reading + 16 μA above 2 mA to 20 mA and at 57 Hz; 0.13% reading + 180 μA above 20 mA to 200 mA and at 57 Hz; 0.26% reading + 3.5 mA above 200 mA to 2 A and at 57 Hz; 0.38% reading+ 35 mA above 2 A to 20 A and at 57 Hz Clamp on ammeters only both on site and at the laboratory 0.52% reading + 400 mA from 20 A to 100 A and at 57 Hz; 0.63% reading + 2.4 A above 100 A to 1000 A and at 57 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC current | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - In the laboratory 37 μA/A + 15 nA up to 200 μA; 38 μA/A + 150 nA above 200 μA to 2 mA; 43 μA/A + 1.5 μA above 2 mA to 20 mA; 122 μA/A + 14 μA above 20 mA to 200 mA; 460 μA/A + 97 μA above 200 mA to 2 A; 0.11% reading + 3.9 mA above 2 A to 20 A On site calibrations 230 μA/A + 31 nA from 20 μA to 200 μA; 170 μA/A + 200 nA above 200 μA to 2 mA; 150 μA/A + 1.9 μA above 2 mA to 20 mA; 190 μA/A + 27 μA above 20 mA to 200 mA; 610 μA/A + 710 μA above 200 mA to 2 A; 0.16% reading+ 20 mA above 2 A to 20 A Clamp on ammeters both on site and at the laboratory 0.48% reading + 180 mA from 20 A to 100 A; 0.53% reading + 1.3 A above100 A to 1000 A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Digital multimeters (DMM); Ohm meters | Resistance | Comparison with a reference standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - In the laboratory 20 μΩ/Ω + 7.2 μΩ up to 2 Ω; 14 μΩ/Ω + 91 μΩ above 2 Ω to 20 Ω; 12 μΩ/Ω + 810 μΩ above 20 Ω to 200 Ω; 12 μΩ/Ω + 5.8 mΩ above 200 Ω to 2 kΩ; 12 μΩ/Ω + 53 mΩ above 2 kΩ to 20 kΩ; 16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 170 μΩ/Ω + 20 kΩ above 19 MΩ to 200 MΩ; 0.15% reading + 2.6 MΩ above 200 MΩ to 2 GΩ; 0.35% reading + 47 MΩ above 2 GΩ to 20 GΩ; For on site calibrations 1.2% reading from 1 Ω to 10 Ω; 0.6% reading above 10 Ω to 100 Ω; 0.12% reading + 50 mΩ above 100 Ω to 1 kΩ; 0.12% reading + 500 mΩ above 1 kΩ to 10 kΩ; 0.12% reading + 5 Ω above 10 kΩ to 100 kΩ; 0.12% reading+ 50 Ω above 100 kΩ to 1MΩ; Insulation resistance testers up to 1kV both on site and at the laboratory 1.9% reading from 10 MΩ to 100 MΩ;
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Digital multimeters (DMM); Voltmeters | DC voltage | Comparison with a reference standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - In the laboratory 17 μV/V + 6.3 μV up to 200 mV; 13 μV/V + 21 μV above 200 mV to 2 V; 13 μV/V + 47 μV above 2 V to 20 V; 17 μV/V + 580 μV above 20 V to 200 V; 18 μV/V + 8.7 mV above 200 V to 1000 V For on site calibrations Calibration and Measurement Capability of - 230 μV/V + 7 μV from 2 mV to 20 mV; 43 μV/V + 16 μV above 20 mV to 200 mV; 19 μV/V + 130 μV above 200 mV to 2 V; 16 μV/V + 1.3 mV above 2 V to 20 V; 42 μV/V + 16 mV above 20 V to 200 V; 34 μV/V + 130 mV above 200 V to 1000 V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC voltage | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - In the laboratory280 μV/V + 23 μV up to 200 mV and from 40 Hz to 100 Hz; 260 μV/V + 440 μV above 200 mV to 2 V and from 40 Hz to 100 Hz; 200 μV/V + 400 μV above 2 V to 20 V and above 100 Hz to 2 kHz; For onsite calibrations 0.2% reading + 150 μV from 2 mV to 20 mV and at 57 Hz; 750 μV/V + 180 μV above 20 mV to 200 mV and at 57 Hz; 570 μV/V + 650 μV above 200 mV to 2 V and at 57 Hz; 570 μV/V + 6.8 mV above 2 V to 20 V and at 57 Hz; 910 μV/V + 68 mV above 20 V to 200 V and at 57 Hz; 0.12% reading + 340 mV above 200 V to 1000 V and at 57 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC and low frequency electrical metrology - Electrical standards | Conductance boxes; Precision resistors; Resistance boxes | Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 20 μΩ/Ω + 5 μΩ up to 2 Ω; 14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 12 μΩ/Ω + 51 mΩ above 2 kΩ to 20 kΩ; 16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 170 μΩ/Ω + 19 kΩ above 20 MΩ to 200 MΩ; 0.15% reading + 2.6 MΩ above 200 MΩ to 2 GΩ; 0.35% reading + 47 MΩ above 2 GΩ to 20 GΩ; 0.75% reading + 0.056%/GΩ above 20 GΩ to 90 GΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges | Gauge pressure | By pressure calibrator | AS 1349 ; MSA Test Method 1 ; MSA Test Method 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibrations performed in the Laboratory and Mobile Vans With Calibration and Measurement Capability of - 0.05% of reading or 0.01 kPa (whichever is greater) at -95 kPa to 70 MPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time and frequency metrology - Frequency, time and waveform measuring equipment | Counters; Frequency meters | Frequency | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - in the laboratory calibration for Frequency2.3 Hz/MHz from 10 Hz to 100 kHz; onsite calibration of Frequency Meters 52 Hz/MHz from 10 Hz to 100 kHz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tachometers | Rotational speed | Comparison with a reference standard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations With Calibration and Measurement Capability of- 52 rpm/1,000,000rpm + 1 rpm from 600 rpm to 60,000 rpm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Torque - Torque measuring and testing equipment | Torque transducers | Torque | Gravimetric measurement with reference beam | To the method of BS 7882 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.4% of reading from 1.25 N.m to 25 N.m 0.1% of reading from 25 N.m to 1500 N.m | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Torque wrenches | Torque | Comparison with a reference standard | ASME B 107.300 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibrations performed in the Laboratory and Mobile Vans With Calibration and Measurement Capability of - 1.0% of reading from 1.25 Nm to 1500 Nm |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.