National Association of Testing Authorities, Australia
Scope of Accreditation
Tex@Site Pty Ltd
Site
NATA Laboratory
Accreditation No.
15281
Site No.
15902
Date of Accreditation
16 Jul 2007
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DC and low frequency electrical metrology - Electrical instrument calibrators | Instrument calibrators | AC current; AC voltage; DC current; DC voltage; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability ofDC voltage 17 μV/V + 6.3 μV up to 200 mV; 10 μV/V + 15 μV above 200 mV to 2 V; 10 μV/V + 120 μV above 2 V to 20 V; 15 μV/V + 1.5 mV above 20 V to 200 V; 13 μV/V + 12 mV above 200 V to 1000 V DC current 30 μA/A +11 nA up to 200 μA; 30 μA/A + 70 nA above 200 μA to 2 mA; 40 μA/A + 700 nA above 2 mA to 20 mA; 100 μA/A + 20 μA above 20 mA to 200 mA; 390 μA/A + 530 μA above 200 mA to 2 A; 0.11% reading + 3.9 mA above 2 A to 20 A AC voltage 300 μV/V + 4.6 μV up to 200 mV and from 40 Hz to 100 Hz; 260 μV/V + 440 μV above 200 mV to 2 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV above 2 V to 20 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV above 20 V to 200 V and from 40 Hz to 100 Hz; 260 μV/V + 140 mV above 200 V to 1000 V and from 40 Hz to 100 Hz; 260 μV/V + 430 μV up to 200 mV and above 100 Hz to 2 kHz; 240 μV/V + 420 μV above 200 mV to 2 V and above 100 Hz to 2 kHZ; 200 μV/V + 400 μV above2 V to 20 V and above 100 Hz to 2 kHz; 230 μV/V + 380 μV above 20 V to 200 V and above 100 Hz to 2 kHz; 260 μV/V + 140 mV above 200 V to 1000 V and above 100 Hz to 2 kHz; 400 μV/V + 24 μV up to 200 mV and above 2 kHz to 10 kHz; 260 μV/V + 380 μV above 200 mV to 2 V and above 2 kHz to 10 kHz; 220 μV/V + 1.6 mV above 2 V to 20 V and above 2 kHZ to 10 kHZ; 220 μV/V + 16 mV above 20 V to 200 V and above 2 kHz to 10 kHz; 260 μV/V + 140 mV above 200 V to 1000 V and above 2 kHz to 10 kHz AC current 780 μA/A + 68 nA from 30 μA to 200 μA and from 10 Hz to 10 kHz; 460 μA/A + 470 nA above 200 μA to 2 mA and from 10 Hz to 10 kHz; 460 μA/A + 4.7 μA above 2 mA to 20 mA and from 10 Hz to 10 kHz; 690 μA/A + 47 μA above 20 mA to 200 mA and above 10 Hz to 10 kHz; 0.11% reading + 1.1mA above 200 mA to 2 A and above 10 Hz to 2 kHz; 0.13% reading + 8.2mA above 2 A to 20 A and above 10 Hz to 2 kHz; 0.13% reading + 1.1 mA above 200 mA to 2 A and above 2 kHz to 10 kHz; 0.36% reading + 13 mA above 2 A to 20 A and above 2 kHz to 10 kHz Resistance 20 μΩ/Ω + 5 μΩ up to 2 Ω; 14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 12 μΩ/Ω + 51 mΩ above 2 kΩ to 20 kΩ; 16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 170 μΩ/Ω + 19 kΩ above 20 MΩ to 200 MΩ; 0.15% reading+ 2.6 MΩ above 200 MΩ to 2 GΩ; 0.35% reading+ 47 MΩ above 2 GΩ to 20 GΩ; 0.75% reading+ 0.056%/GΩ above 20 GΩ to 90 GΩ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Current clamps; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Voltmeters | AC current; AC voltage; DC current; DC voltage; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of DC voltage AC current
1.9% reading from 10 MΩ to 100 MΩ; Insulation resistance testers up to 5kV 2.6% reading from 100 MΩ to 200 MΩ; |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC and low frequency electrical metrology - Electrical standards | Conductance boxes; Precision resistors; Resistance boxes | Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of - 20 μΩ/Ω + 5 μΩ up to 2 Ω; 14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 12 μΩ/Ω + 51 mΩ above 2 kΩ to 20 kΩ; 16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 170 μΩ/Ω + 19 kΩ above 20 MΩ to 200 MΩ; 0.15% reading + 2.6 MΩ above 200 MΩ to 2 GΩ; 0.35% reading + 47 MΩ above 2 GΩ to 20 GΩ; 0.75% reading + 0.056%/GΩ above 20 GΩ to 90 GΩ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges | Gauge pressure | Comparison with reference instrument |
MSA Test Method 1 ; MSA Test Method 2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of - 0.05% of reading or 0.01 kPa (whichever is greater) at -95 kPa to 70 MPa |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Time and frequency metrology - Frequency, time and waveform measuring equipment | Counters; Frequency meters | Frequency | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of - 2.3 Hz/MHz from 10 Hz to 100 kHz; |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Time and frequency metrology - Frequency, time and waveform measuring equipment | Tachometers | Rotational speed | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of- 0.2% from 600 rpm to 60,000 rpm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Torque - Torque measuring and testing equipment | Torque transducers | Torque | Gravimetric measurement with reference beam | To the method of BS 7882 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of -0.4% of reading from 1.25 N.m to 25 N.m 0.1% of reading above 25 N.m to 1500 N.m |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Torque - Torque measuring and testing equipment | Torque wrenches | Torque | Comparison with a reference standard |
ASME B 107.300 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability with Calibration and Measurement Capability of - 1.0% of reading from 1.25 Nm to 1500 Nm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ISO/IEC 17025 (2017)
Calibration
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Current clamps; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Voltmeters | AC current; AC voltage; DC current; DC voltage; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability Including calibrations performed in dedicated mobile vans with Calibration and Measurement Capability of - DC voltage
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges | Gauge pressure | Comparison with reference instrument |
MSA Test Method 1 ; MSA Test Method 2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability Including calibrations performed in dedicated mobile vans with Calibration and Measurement Capability of - 0.1% of reading from -95 kPato -7 kPa: |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Time and frequency metrology - Frequency, time and waveform measuring equipment | Frequency meters | Frequency | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability Including calibrations performed in dedicated mobile vans with Calibration and Measurement Capability of - 52 Hz/MHz from 10 Hz to 100 kHz |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Time and frequency metrology - Frequency, time and waveform measuring equipment | Tachometers | Rotational speed | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability Including calibrations performed in dedicated mobile vans with Calibration and Measurement Capability of- 0.2% from 600 rpm to 60,000 rpm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Torque - Torque measuring and testing equipment | Torque wrenches | Torque | Comparison with a reference standard |
ASME B 107.300 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability Including calibrations performed in dedicated mobile vans with Calibration and Measurement Capability of - 1.0% of reading from 1.25 Nm to 1500 Nm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.