National Association of Testing Authorities, Australia
Scope of Accreditation
HRL Technology Group Pty Ltd
Site
Non-Destructive Testing
Accreditation No.
561
Site No.
11459
Date of Accreditation
21 Nov 1995
Contact
Mr Matthew Baxter P: +61 (03) 51321562
Availability
Services available to external clients
Scope of Accreditation
Non-Destructive Testing
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Non-destructive testing (NDT) - Magnetic particle testing | Metallic surfaces - Magnetic | Defect detection and characterisation | AC magnetic flow; Coil | ||
Non-destructive testing (NDT) - Penetrant testing | Metallic surfaces; Non-metallic surfaces | Defect detection and characterisation | Solvent removable; Water washable | ||
Non-destructive testing (NDT) - Ultrasonic testing | Bonded metals; Rolled or wrought steel products | Defect detection and characterisation | A-scan - Manual | ||
Castings; Forgings; Metallic components; Metallic piping; Metallic plate; Metallic tubes - Ferromagnetic materials; Metallic tubes - Non-ferromagnetic materials | Material loss characterisation; Profiling | A-scan - Manual | |||
Material thickness - Spot/grid only | A-scan - Manual; Thickness meter | ||||
Welded joints - Ferritic materials | Defect detection and characterisation | A-scan - Manual | |||
Non-destructive testing (NDT) - Ultrasonic testing - Specialised - Phased array (PAUT) | Castings; Forgings; Metallic components; Metallic piping; Metallic plate; Metallic tubes - Ferromagnetic materials; Metallic tubes - Non-ferromagnetic materials | Material loss; Profiling | Manual | ||
Welded joints - Ferritic materials | Defect detection and characterisation | Automatic; Manual |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
561
Site No.
11459
Print date
25 Nov 2024
END OF SCOPE