NXTGEN Air Solutions Pty Ltd

NXTGEN Air Solutions Pty Ltd

Site

NXTGEN Air Solutions Pty Ltd

NXTGEN Air Solutions Pty Ltd

Accreditation No.

21129

Site No.

25416

Date of Accreditation

28 Jun 2023

Address

Unit 2, 187 Kennedy Drive
Tweed Heads, NSW 2485
Australia

nxtgenas.com.au

Contact

Mr Kurt Joseph Markwick P: +61 0411756228

Availability

Services available to external clients

Scope of Accreditation

NXTGEN Air Solutions Pty Ltd

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Biological safety cabinets Ultraviolet intensity Not applicable AS 1807 clause 4.10 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.2
Inward air velocity Cold DOP AS 1807 clause 4.8 For determining compliance with AS 2252.1 (2002)
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.2
Sound level Not applicable AS 1807 clause 4.7 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Air barrier containment Cold DOP AS 1807 clause 4.9 For determining compliance with AS 2252.2
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Particle count in work zone Automatic particle counter AS ISO 14644.1 Appendix A for compliance with:
AS 2252.1 (2002),
AS 2252.2
Clean rooms Air flow Not applicable AS ISO 14644 Part 3 Method B.3
Clean rooms, pharmaceutical isolators and work stations Particle count in work zone Automatic particle counter AS ISO 14644.1 Appendix A for compliance with:
AS 2252.6 (Clean Workstation),
AS ISO 14644.1 (Clean Room),
AS ISO 14644.3 (Clean Room)
Clean rooms; Clean workstations Air velocity and uniformity of air velocity Not applicable AS ISO 14644 Part 3 Method B.2
Relative humidity (RH) Not applicable AS ISO 14644 Part 3 Method B.6
Sound level Not applicable AS 1807.16 (2000)
Integrity of HEPA filter installations Cold DOP AS ISO 14644 Part 3 Method B.7
Air pressure Not applicable AS ISO 14644 Part 3 Method B.1
Temperature Not applicable AS ISO 14644 Part 3 Method B.5
Clean workstations Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with AS 2252.6
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.6
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with AS 2252.6
Sound level Not applicable AS 1807 clause 4.7 For determining compliance with AS 2252.6
Ultraviolet intensity Not applicable AS 1807 clause 4.10 For determining compliance with AS 2252.6
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with AS 2252.6
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.6
Cytotoxic drug safety cabinets Air barrier containment Cold DOP AS 1807 clause 4.9 For determining compliance with AS 2252.5
Ultraviolet intensity Not applicable AS 1807 clause 4.10 For determining compliance with AS 2252.5
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.5
Particle count in work zone Automatic particle counter AS ISO 14644.1 Appendix A for compliance with:
AS 2252.1 (2002),
AS 2252.5
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with AS 2252.5
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.5
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with AS 2252.5
Sound level Not applicable AS 1807 clause 4.7 For determining compliance with AS 2252.5
Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with AS 2252.5
Fume cupboards and recirculating fume cabinets Sound level Not applicable AS 1807 clause 4.7 For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Extraction performance Face velocity AS/NZS 2243.8 section Appendix B,
AS/NZS 2243.9 section Appendix B
For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Extraction performance Smoke visualisation AS/NZS 2243.8 Appendix A,
AS/NZS 2243.9 Appendix A

For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Pharmaceutical isolators Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with AS 4273
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with AS 4273
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 4273
Air pressure Not applicable AS ISO 14644 Part 3 Method B.1 For determining compliance with AS 4273

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.