National Association of Testing Authorities, Australia
Scope of Accreditation
Kingfisher International Pty Ltd
Site
Optical Calibration Laboratory
Accreditation No.
20533
Site No.
24605
Date of Accreditation
07 Nov 2019
Contact
Mr Bruce Robertson
P: +61 (03) 85441750
Availability
Services available to external clients
Scope of Accreditation
Optical Calibration Laboratory
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Optical metrology - Optical measuring equipment | Fibre optic systems | Power - Optical fibre; Wavelength | Direct comparison against a reference meter; Direct comparison against a reference spectrometer | IEC 61315 Ed. 2.0, Method 1, 2, 3, 4, 5, 6 and 7 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of-Wavelength 0.5 nm from 350 nm to 1700 nm Power - Optical fibre 0.06 dB or 1.4% of reading whichever is greater from 350 nm to 1650 nm in steps of 5 nm +10 to -60 dBm / 10 mW - 1 nW. Maximum power per IEC 60825 Class 1M / 2M Return loss - Optical fibre 0.04 dB at 850 nm, 1310 nm, 1550 nm in the range from -60 dB to 0 dB |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fibre optic systems; Laser energy meters; Laser power meters; Photodiodes; Radiometers | Responsivity | Direct comparison against a reference meter | Methods 1, 2, 6 and 7 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Photodiodes and radiometers with Fibre Optic interfacewith Calibration and Measurement Capability of- 0.06 dB or 1.4% of the reading whichever is greater from 350 nm to 1650 nm in 5 nm steps, -60 dBm to 3 dBm / 10 uW - 1 nW and wavelength accuracy of 0.5 nm, using non-coherent light. In accordance with TIA-455-231 / IEC 61315 / FOTP 231 Calibration of Fibre Optic Power Meters |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Linearity | Direct comparison against a reference meter |
IEC 61315 Ed. 2.0, Methods 1, 2. 3. 4, 6 and 7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Photodiodes and radiometers with Fibre Optic interfacewith Calibration and Measurement Capability of - 0.01 dB per 10 dB or 0.2% of the reading whichever is greater from -70 dB to 10 dB at 1310 nm & 1550 nm, and from -70 dBm to 0 dBm at 650 nm & 850 nm, non-coherent broadband light, 0.1 dB per 10 dB or 0.7% of the reading whichever is greater from -60 dBm to 10 dBm at 850 nm, 1310 nm & 1550 nm, using coherent laser light. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20533
Site No.
24605
Print date
10 Dec 2023
END OF SCOPE