Cameron Services International Pty Ltd

Site

Perth Laboratory

Accreditation No.

14340

Site No.

14333

Date of Accreditation

03 Apr 2000

Address

450 Belmont Avenue
Kewdale, WA 6105
Australia

cameron.slb.com

Contact

Mr Winter Culman P: +61 (08) 61899183

Availability

Services available to external clients

Scope of Accreditation

Perth Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Hydrostatic pressure Not applicable ISO 1402 Sections 7 and 8.1 Up to 207 MPa;
Including on-site testing
Piping Pneumatic pressure Not applicable ASME B31.1 Chapter 6 Section 137.5 and 137.6, ASME 31.3 Chapter 6 Sections 345, AS 4041 clauses 6.6, 6.8.1, and 6.9, Up to 207 MPa;
Including on-site testing
Hydrostatic pressure Not applicable ASME B31.1 Chapter 6 Section 137.4, ASME B31.3 Chapter 6 Sections 345, AS 4041 clauses 6.6, 6.7 and 6.9 Up to 207 MPa;
Including on-site testing
Pressure fittings Pneumatic pressure Not applicable API 6DX clause 11 (pressure testing only) Up to 207 MPa;
Including on-site testing
Pressure vessels Hydrostatic pressure Not applicable AS 1210 Section 5.10, AS 4037 Clause 17, ASME VIII Division 1 Clause UG-99, ASME Section 1 BPVC, Clause PG-99  Up to 207 MPa;
Including on-site testing
Pneumatic pressure Not applicable AS 1210 Section 5.11, AS 4037 Clause 18 Up to 207 MPa;
Including on-site testing
Valves Hydrostatic pressure Not applicable ANSI FCI 70-2 Section 4 and 5,
API 6A Clause 7.4.9 and 10.16.6, API 6D Section 9 and Annex H, API 6DSS Clauses 11 and Annex B, API 526 Section 9, API 527 Section 4, API 576 clause 6.2 and Appendix A, API 598 Section 5 and 6,
ASME B16.34 Section 7, ASME Section 1 BPVC Clause PG 73.5,
 BS EN 12266 Part 1,
 ISA 75:19.01,
 AS 1271 clauses 2.6 and 3.4, ISO 4126.4 Clause 6.3,  ISO 5208 Section 4,
 MSS SP-61 Section 3, 4 and 5
Up to 207 MPa;
Including on-site testing
Pneumatic pressure Not applicable ANSI FCI 70-2 Section 4 and 5,
API 6A Clause 7.4.9 and 10.16.6, API 6D Annex H, API 6DSS Clauses 11 and Annex B, API 526 Section 9, API 527 Section 2 and 5, API 576 clause 6.2 and Appendix A, API 598 Section 5 and 6,
API 2000 Clause 5.4,
ASME Section 1 BPVC Clause PG 73.5,
 BS EN 12266 Part 1,
 ISA 75:19.01,
 AS 1271 clauses 3.4, ISO 4126.4 Clause 6.4 and 6.6,  ISO 5208 Section 4,
ISO 28300 Clause 6.4,
 MSS SP-61 Section 3, 4 and 5
Up to 207 MPa;
Including on-site testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.