Profluid Pty Ltd

Site

Perth Site

Accreditation No.

20944

Site No.

25168

Date of Accreditation

06 Dec 2021

Address

16 Fellowship Road
Gnangara, WA 6077
Australia

profluid.com.au

Contact

Mr Jerome Monteiro P: +61 0405602224

Availability

Services available to external clients

Scope of Accreditation

Perth Site

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Piping Leakage; Pneumatic pressure Not applicable ASME B16.1 section 8
Up to 140 MPa including on-site testing.
Hydrostatic pressure; Leakage Not applicable AS 4041 sections 6.6, 6.7, 6.8, 6.9, 6.10;
ASME B16.1 section 8;
ASME B31.3 Chapter VI section 345, Chapter VII Part 10 section A345, Chapter VIII section MA345, and Chapter IX section K345
Up to 140 MPa including on-site testing.
Valves Hydrostatic pressure; Re-seating pressure; Seat leakage; Set pressure Not applicable ANSI/FCI 70-2 sections 4 and 5,
ANSI/ISA 75.19.01
API 526 section 9,
API 527 section 4,
API 576 section 6.2 and Appendix A,
API 598 sections 5 and 6,
API 609 section 6.3,
API 6D sections 9, 11 and Annex H,
AS 1271,
ASME B16.34 section 7,
BS EN 12266-1,
ISO 14313,  
ISO 5208 section 4,
JIS B 2032 section 8
Up to 140 MPa including on-site testing
Pneumatic pressure; Re-seating pressure; Seat leakage; Set pressure Not applicable ANSI/FCI 70-2 sections 4 and 5;
ANSI/ISA 75.19.01;
API 526 section 9;
API 527 sections 2 and 5;
API 576 section 6.2 and Appendix A;
API 598 sections 5 and 6;
API 609 section 6.3;
API 6D sections 9, 11, and Annex H,
AS 1271;
ASME B16.34 Chapter VI section 345, Chapter VII Part 10 section A345, Chapter VIII section MA345, Chapter IX section K345;  
BS EN 12266-1;
ISO 5208 section 4
Up to 140 MPa including on-site testing.

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.