National Association of Testing Authorities, Australia
Scope of Accreditation
Queensland Testing Laboratory Pty Ltd
Site
QTL Laboratory
Accreditation No.
14783
Site No.
14894
Date of Accreditation
20 Jun 2003
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of load handling, rigging and tensioning systems | Pallets | Bending; Bending - Bottom deck; Bending - Wing pallet; Coefficient of friction; Compression tests for blocks or stringers; Corner drop; Forklifting; Proof load; Stacking; Static shear | Not applicable | ISO 8611.1 clauses 8.1, 8.2, 8.3, 8.4, 8.5, 8.6, 8.8, 8.9, 8.13 | For compliance to ISO 8611.2 Table 1 |
Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Abrasion resistance; Ageing; Burst pressure; Dimensions; Dispersal rate of a hose reel discharge; Distortion; Ease of opening a nozzle, other than a twist nozzle, to the open position; Ease of turning a twist nozzle to the open position; Expansion; Flexibility; Flow rate of a hose reel; Functionality testing; Hose and coupling compatibility; Hose reel assembly pressure; Hydrostatic pressure; Length change; Lining adhesion; Low temperature flexibility; Resistance to distortion of the side plates of a hose reel; Resistance to load of a swing hose reel assembly; Serviceability after kinking | Not applicable | AS 2792 clauses 3.1.2, 3.1.3, 3.1.4, 3.1.5, 3.1.6, 3.1.7, 3.3.1, 3.3.2, 3.3.3; AS/NZS 1221 clauses 2.2.1.5, 2.2.1.6, 2.2.1.7, 2.2.1.8, 2.2.2.2, 2.2.2.3, 3.2.1, 3.2.2.1, 3.2.2.2, 3.2.2.3, 3.2.3, 3.2.4.2, 3.2.4.3 and Appendices B, C, D, E, F, G; AS/NZS 2554 clauses 1.6, 2.2.1, 2.2.2, 2.2.3, 2.2.4, 2.3, 2.4 WMTS-533 | Fire hose and fire hose reels |
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of fire protection and mitigation equipment | Fire extinguishers | Discharge performance; Impact; Leakage; Pressure withstand | Not applicable | AS 4265 clauses 3.1.2, 3.1.3, 3.3, 3.4, 3.5, 4.2, 4.3, 4.4, 6.2.1, 6.3, Appendix A | |
Assessment of organic linings; Compaction; Discharge performance; Impact; Leakage; Pressure withstand | Not applicable | AS/NZS 1841.1 clauses 5.2, 5.3, 6.2.1, 6.2.2, 6.4, 6.5, 6.6.3, 6.7, 6.8, 6.9, 6.10, 6.11, 6.12, 6.13, 9, 9a, 9b, and Appendices B, C; AS/NZS 1841.5 clause 5; AS 4265 clauses 3.1.2, 3.1.3, 3.3, 3.4, 3.5, 4.2, 4.3, 4.4, 6.2.1, 6.3, Appendix A | |||
Material performance evaluation of elastomers, plastics and composite products | Pipe material and related products; Plastic waste water valves and fittings; Prepared test specimens | Bending properties; Compression; Crushing decohesion; Decohesion; Dimensions; Flexing; Formability; Heat resistance; Impact resistance; Peel decohesion; Pull-out strength; Strength; Vicat softening temperature; Visual examination | Not applicable | AS/NZS 2053.1 clauses 8.1, 8.2, 8.3, 8.4, 9.2, 9.3, 9.4, 9.5, 9.6 and Appendices A, B, C, D; AS/NZS 2053.5 clauses 6, 7, 8, 9, 10, and Appendices AA, BB, CC, DD AS/NZS 1462.5;ISO 13954; ISO 13955; ISO 13956 | |
Mechanical performance evaluation of components for building envelopes, framing and interior lining | Cable trunking systems | Cable trunking system cover retention; Cable trunking system supporting capacity; Impact resistance; Resistance to linear deflection | Not applicable | AS/NZS 4296 clauses 8, 9, 10 and Appendices D, E, G | |
Products and appliances connected to the water supply - Physical evaluation | Back flow prevention devices; Flow controllers; Tap assemblies; Valves | Adhesion; Air gap; Back flow; Back pressure; Back siphonage; Closing pressure; Degradation by ultraviolet light; Dimensions; Discharge; Discharge rate; Discharge volume; Endurance; Flow rate; Hydrostatic pressure; Impact resistance; Infiltration; Inflow and overflow; Leak tightness; Leak tightness under external pressure; Leakage; Pressure; Resistance to handle removal; Seat tightness; Switching time; Temperature evaluation; Thermal cycling; Torque; Visual examination; Water tightness; Water trap seal | Not applicable | AS 1357.1 clauses 3.2.1, 3.2.2, 3.3, 4, 5, 6, 7, 8 and Appendices E, F, G, H, I, J, K, L, M, N, O, P, Q, R; AS 1357.2 clauses 3.2.1, 3.2.2, 6.2, 6.4, 6.5, 6.6, 7.2, 7.4, 7.5, 9.2, 9.4, 9.5 and Appendices L, M, N, V, W; AS 1628 clauses 4.2, 4.3, 4.4, 4.5, 5, 6 and Appendices B, C, D; AS 1910 clauses 4.2, 4.3, 4.4 and Appendices C, D, E; AS 2419.2 clauses 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6 and Appendices D3, D4, D5, D6, D7; AS 2419.3 clauses 4.3.5 and Appendix D6; AS 2845.2 (1996) clauses 4.1, 4.2 and Appendix A. (This superseded standard is called up in WMTS-101 clause 8.2); AS 3718 (excluding clause 4.7); AS 3952 clauses 3.3.1, 3.3.3, 5.1.1, 5.1.2, 5.1.3, 5.4.1 and Appendix A; AS 4032.1 clauses 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10 and Appendices D, E, F, G, H, I, J; AS 4032.2 clauses 3.2, 3.3.1, 3.3.2, 3.4, 4.4 and Appendices C, D, F, G; AS 4032.4 clauses 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10, 4.11, 4.12, 4.13, 4.14, 4.15, 4.16 and Appendices C, D, E, F, G, H, I, J, K, L, M, N; AS 4794 clauses 5.1.2, 5.1.3, 5.1.4, 5.2.2, 5.2.3, 5.2.4 and Appendices D, E; AS 4795.1 clauses 5.2.1 Test A, 5.2.2 Test B, 5.2.3 Test C, 5.2.4 Test D, 5.2.5 Test E, 5.2.6 Test F; AS 4795.2 clauses 5.2.1 Test A, 5.2.2 Test B, 5.2.3 Test C, 5.2.4 Test D, 5.2.5 Test E, 5.2.6 Test F; AS 4796 clauses 4.2, 4.3, 4.4.1, 4.5, 4.7, 4.8, and Appendices E, F, G, H, I; AS 5081 clauses 5.2.2, 5.2.3, 5.2.4, 5.2.5, 5.2.6, 5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.3.7, 5.3.8, 5.3.9; AS 5200.037.2 clauses 8.1, 9.2, 9.3, 9.4.2, 9.4.3 and Appendices B, C; AS/NZS 2638.1 clauses 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.6, 5.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12; AS/NZS 2638.2 clauses 3.2, 3.3, 5.1.1, 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.6, 5.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12, 5.1.13, 5.1.14, 5.1.15; AS/NZS 2845.1; EN 1267 clauses 5, 6; EN 1680; EN 1705; EN 12201-4 clause 7.2 and Annex A; ISO 5208; ISO 10933 clause 9.7; ISO/EN 817 clauses 8.3, 8.4, 8.5, 8.6, 8.7, 9.4, 9.5, 10.2, 10.4, 10.5, 10.6, 10.7, 11.2, 12.1, 12.2, 12.3, 13 and Annexes A, B; WMTS-006 clauses 8.3, 9.1, 9.2, 9.3, 9.4 and Appendix A; WMTS-012 clauses 9.2, 9.4.1, and Appendix B; WMTS-026 Sections 8.1, 8.2; WMTS-030 clauses 9.3, 9.4, 9.5, 9.6 and Appendices C, D, E; WMTS-052 clauses 9.2, 9.3, 9.4, 9.5, 9.6; WMTS-420 clauses 9.1, 9.2, 9.3, 9.4; WMTS-453 clause 9; WMTS-464 clauses 8.1, 8.2, 8.3, 9.2, 9.3, 9.4, WMTS-467 clauses 8.1, 8.3, 9.1, 9.3.2, 9.4; WMTS-468; WMTS-476 clauses 8.1, 8.2, 8.3, 8.4, 9.1, 9.2, Appendix B, C, WMTS-479 clauses 9.2, 9.3, 9.4 and Appendices B, C; WMTS-481 clauses 9.2, 9.3, 9.4.1, 9.4.2, 9.4.3, 9.5 and Appendices B, C, WMTS-528 clause 8.2, 8.4, 9.2, 9.3, 9.5, Appendix B | Control valves, Metallic gate, globe and non-return valves, float control valves, fire hydrant valves, hydrant booster connections, gate values- metal, thermostatic mixing valves, tempering valves, thermostatically controlled taps, non return valves-swing check, Butterfly valves, metal and plastic bodied ball valves, hydraulically operated automatic control valves, reflux valves, inline valves, solenoid valves, heated water systems, rainwater tank connection valves, thermal switching valves, mechanical mixing valves |
Beverage dispensers and icemakers; Food waste disposal units; Peelers - Fruit and vegetable; Water treatment appliances and systems | Air gap; Back flow; Degree of fineness (FWDU); Dimensions; Discharge; Drainage; Endurance; Pressure; Pressure cycling resistance; Pressure fatigue; Seal integrity; Strength of assembly | Not applicable | AS 3497 clauses 5.2, 5.3, 5.4; WMTS-028 clause 9; WMTS-101 clauses 8.1, 8.2, 8.3, 9.2, 9.3; WMTS-103 clauses 9.2, 9.3, 9.4; WMTS-104 clause 9.3; WMTS-105 clause 9 | ||
Emergency eyewash and shower equipment | Dimensions; Flow rate; Flushing fluid pattern diameter; Switching time | Not applicable | AS 4775 clauses 6.5.1, 7.3.1, 8.3 | ||
Fire sprinkler heads | Endurance; Hydraulic strength | Not applicable | WMTS-486 clauses 9.2, 9.3, and Appendices B, C | ||
Flow controllers | Rating of products for water efficiency | Not applicable | AS 6400 Section 5 | ||
Sanitary fixtures - Urinals, water closet pan/suites, bidets, douche seats, cisterns and purpose built bathroom modules | Back flow; Back pressure; Back siphonage; Capacity; Discharge volume; Distortion; Endurance; Flow and pressure loss; Flow rate; Flush performance; Flushing cleanliness; Hydrostatic pressure; Leakage; Load; Odour; Pressure; Resistance to stoppage; Splash; Strength of assembly; Thermal cycling; Thrust; Torque; Water tightness; Wetting | Not applicable | ANSI Z124.9 (2004) clause 7.5; AS 1172.1 Section 2; 3 and Appendices A, B, C, D, E, F, G, H; AS 1172.2 clauses 2.4, 2.5, 3.4, 3.5, 4.4, 4.5, 4.7.2, 5.3, 5.4, 6.3, 6.4 and Appendices A, B, C, D, E, F, G, H; AS 1172.6; AS/NZS 3500.1 clause 3.2.1; ATS 5200.004 clauses 9.2, 9.3, 9.4 and Appendices B, C; SA TS 100 Sections 9.1.1, 9.1.2, 9.1.3, 9.1.4, 9.1.5, 9.1.6, 9.1.9, 9.1.10 and Appendices B, C, D, E, F, G, J; WMTS-046 clauses 9.2, 9.3(a), 9.4; WMTS-050 Clause 8.1, 8.2, 8.3, 8.4, 8.5, 8.6, 8.7, 9.2, 9.3 and Appendix B; WMTS-051 clause 9.2 and Appendix B; WMTS-459 clauses 9.1.1, 9.2; WMTS-460 clause 9.1; WMTS-469 clause 9; WMTS-499 Clause 9.2; WMTS-504 clauses 9.1, 9.1.1, 9.1.2, 9.1.3, 9.1.4, 9.1.5, 9.1.6, 9.1.7, 9.1.8, 9.2, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.3, 9.4 and Appendix B, C; WMTS-516 Clauses 9.2, 9.3, 9.4, 9.5, 9.6, 9.7, 9.8, 9.9, 9.10, 9.11 and Appendices B, C, D, E; WMTS-517 clauses 9.1, 9.2, 9.3, 9.4, 9.5 and Appendices A, B, C; WMTS-526 clauses 9.1, 9.2, 9.3, 9.4, 9.5 WMTS-536 | Grey water diversion devices; Offset pan connections; Plastic urinal fixtures; Vacuum water closets; Wash down diversion systems; Waterless or limited flush urinals | |
Air gap; Chemical and stain resistance; Crack propagation; Dimensions; Discharge; Drainage; Impact resistance; Load; Visual examination; Water absorption | Not applicable | AS 1172.3 clauses 2.2, 3.2, 3.3, 3.4, 3.5, 3.6, Appendix B, C AS 1371 clauses Appendix A, C, D, E, F, G AS 1428.1 clauses 12.2.3 excluding 12.2.3 e), 12.2.4, 12.5.9, 14 AS 1976 Appendix A, B, C | |||
Rating of products for water efficiency | Not applicable | AS/NZS 6400 Sections 6 and 7 | Lavatory and urinal equipment | ||
Showers and shower modules | Endurance; Flow rate; Splash; Spread angle; Strength of assembly; Temperature evaluation; Water tightness | Not applicable | AS/NZS 3662 (2005) clauses 5.4.1, 5.4.2, 5.4.3, 5.4.4, 5.5, 5.6.1, 5.6.2 and Appendices B, C, D, E, F, H, I; AS/NZS 3662 clauses 5.4, 5.4.1, 5.4.2, 5.5.1, 5.5.2, 5.5.3, 5.5.4, 5.6, 5.7.1, 5.7.2 and Appendices B, C, D, E, F, H, I; | ||
Rating of products for water efficiency | Not applicable | AS 6400 Section 3 | |||
Tap assemblies | Rating of products for water efficiency | Not applicable | AS 6400 Section 4 | ||
Water heaters | Endurance; Temperature evaluation | Not applicable | AS 3498 including Appendices A, B | ||
Water service products - Connectors, filters, fittings, hoses and pipes | Crack propagation; Dimensions; Hydrostatic pressure; Impact resistance; Infiltration; Joint strength; Leak tightness; Leak tightness under external pressure; Load; Pressure; Residual stress; Resistance to internal pressure (hydrostatic strength); Reversion; Seal closing evaluation; Seal integrity; Temperature evaluation; Thermal cycling; Torque; Vacuum pressure; Water tightness | Not applicable | AS 1432 clauses 4.3, 5.4.2; AS 1589 clauses 1.7.4, 1.7.5, 1.9.2, 1.10, 1.13.3 up to DN 80, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.5, 3.4.1, 3.4.2, 3.4.3, 3.5.1, 3.6.1; AS 1683.13 (1992); AS 1926.3 clauses 5, 6.1, 6.2 and Appendices A5.1, A5.2, A5.3, A5.4, B; AS 2280 clauses 2.5.2, 3.1, 3.1.1, 3.1.2.1, 3.1.2.2, 3.1.2.3, 3.1.2.4, 3.5.2.1, 3.5.2.2, 4.2.2 and Appendices F, H; AS 2419.3 clauses 4.2, 4.2.2, 4.2.3, 4.3, 4.3.2, 4.3.3, 4.3.4, 4.3.6; AS 2887; AS 2888.1; AS 2888.2; AS 2888.3; AS 2888.4; AS 2888.5; AS 2888.6; AS 2888.7; AS 2888.8; AS 2888.9; AS 2888.10; AS 2888.11; AS 3499 clauses 6.2, 6.3, 6.4, 6.5, 6.6, 6.7, 6.8, 6.10 ; AS 3518 (2004); AS 3688 clauses 3.2, 3.4, 3.5, 3.6, 3.7.1, 3.7.2, 3.8, 4.1.3, 4.1.4, 4.1.7 (types F and R), 4.2, 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10 and Appendices D, E, F, G, H, I, J, K, L; AS 3707; AS 4176 (1994) Appendix G; AS 4181 clauses 4.1.3, 4.1.4, 4.1.5, 4.1.6, 4.1.7 (types F and R); AS 4793 clauses 4.1.2, 4.1.3, 4.1.4, 4.1.5, 4.1.6, 4.1.7 and Appendices B, C, D; AS 5082.2 clauses 12.1, 12.2, and Appendices C, D, E, F, G, H; AS 6400 Section 5; AS/NZS 1260 clauses 3.2.1, 3.2.2, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.7, 3.4.2, 3.4.3, 3.4.4, 4.2, 4.3, 4.4, 4.5, 5.2, 5.2.3, 5.2.4, 5.3, 5.4, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 6.3, 7.3; AS/NZS 1462.1 (clauses 7, 8, 11); AS/NZ 1462.3 AS/NZS 1462.4; AS/NZS 1462.6; AS/NZS 1462.8; AS/NZS 1462.10; AS/NZS 1462.11; AS/NZS 1462.13; AS/NZS 1462.22; AS/NZS 1477 clauses 3.3.1, 3.3.2, 3.3.3, 3.3.6, 3.5.1, 3.5.2; AS/NZS 1571 clause 8.2; AS/NZS 2492 clauses 3.8, 3.9; AS/NZS 2537.3; AS/NZS 2642.3 clauses 12.2.1, 12.2.2, 12.2.3, 12.2.4, 12.2.5, 12.2.6, 12.2.7, 12.2.8 and Appendices C, D, E, F; AS/NZS 3499 clauses 8.2, 8.3, 8.4b, 8.6, 8.7, 8.8, 8.11; AS/NZS 3879 clauses 8.2, 8.3.1, 8.3.2 and Appendices B, C, D; AS/NZS 4129 clauses 1.7, 1.10,1.13.1, 1.13.2, 2.4.1, 2.4.2, 2.4.3, 2.4.4, 2.4.5, 2.4.6, 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6, 4.3.7, 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6.2, 4.4.6.3; AS/NZS 4130 clauses 9.1, 10.1, 10.2; AS/NZS 4327 clauses 4.1, 4.2 and Appendices B, C, D, E, F; AS/NZS 4401 clauses 6.2, 6.3, 6.4, 7.2, 8; AS/NZS 4441 clauses 10, 11.1.1, 11.1.2, 13.2, 13.3, 13.4; AS/NZS 4765 clauses 3.2.3, 3.2.4, 3.2.7, 3.2.8, 3.2.9, 3.2.10, 3.3.1, 3.3.2, 3.3.3 and Appendices B, D, E; AS/NZS 4793 (2009) clauses 4.1.2, 4.1.3, 4.1.4, 4.1.5, 4.1.6 and Appendices B, C, D; AS/NZS 4936 clauses 7.3, 7.4, 7.5, 7.6, 7.7 and Appendices A, B, C, D; AS/NZS 4998 clauses 4.1.2, 4.1.3; AS/NZS 5065 clauses 3.3.1, 3.3.2, 3.4.1, 3.4.2, 3.4.3, 5.2; AS/NZS 7671 clauses 6, 8, 9; ASME A112.6.3; BS EN 12842; EN 713; EN 714; EN 1053; EN 1054; EN 1055; EN 1228 clause 7.3; EN 12050-2 clause 8; EN 12050-3 clause 8; EN 12050-4 clauses 8.2.4, 8.2.5; EN 12293; EN 12294; EN 12295; EN 28233; ISO 1167 (1996); ISO 1167-1; ISO 1167-2; ISO 1167-3; ISO 1167-4; ISO 3126; ISO 3459; ISO 3501; ISO 3503; ISO 13257; ISO 13264; ISO 13460-1, ISO 13479; ISO 13844; ISO 13845; ISO 13846; ISO 15875-5; ISO 16422 clauses 10, 11.1.1, 11.1.2, 13.2, 13.3, 13.4; ISO 22391-2 clauses 4, 6, 7, 8; ISO 22391-5; UK-WIS 4-24-01; WMTS-040 clause 9.1, 9.2, 9.3, 9.4; WMTS-047 clauses 9.2, 9.3, 9.4, 9.5, 9.6; WMTS-055 clauses 9.1, 9.2, 9.3, 9.4, 9.5; WMTS-106 clause 8.6, 9.1, 9.2; WMTS-475 clauses 9.2, 9.3 and Appendices B, C; WMTS-477 clause 9 and Appendix C; WMTS-482; WMTS-489 clauses 8.1.1, 8.1.2, 8.1.3, 9 and Appendix B; WMTS-519 clauses 8.1, 8.2, 8.3, 9.1, 9.2, 9.3, 9.4, 9.5, 9.6, 9.7; | Including PVC-U pipes, copper tubing, copper seamless tube (air conditioning and refrigeration), copper alloy waste fittings |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14783
Site No.
14894
Print date
27 Nov 2024