Department of Transport and Planning

Site

Surveyor-General Victoria

Accreditation No.

14954

Site No.

15162

Date of Accreditation

10 Apr 2003

Address

Level 11, 2 Lonsdale Street
Melbourne, VIC 3000
Australia

land.vic.gov.au/surveying/services/equipment-calibration-services

Contact

Mr Alexander Woods P: +61 (03) 91940770

Availability

Services conditionally available to external clients

Scope of Accreditation

Surveyor-General Victoria

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Dimensional metrology - Survey and alignment equipment Baselines; Electronic distance measuring equipment Length measurements Direct measurement

Electronic distance measuring equipment in accordance with QP-0061 

Baselines used for Electronic Distance Measuring (EDM) equipment calibration in accordance with QP-0062 

Capability

with a Calibration and Measurement Capability of -

Electronic distance measuring equipment

(0.7 + 5x10- 3L) mm where L is length in metres from 1 m to 1160 m

Baselines

(0.5 + 1.3x10- 3L) mm where L is length in metres from 5 m to 1160 m

The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

The Product column may also describe an Item or Material.

The Limitations column may also describe the Range.