Switchmode Power Supplies Pty Ltd

Site

Switchmode Power Supplies

Accreditation No.

16641

Site No.

17961

Date of Accreditation

24 Nov 2009

Address

1/37 Leighton Place
Hornsby , NSW 2077
Australia

switchmode.com.au

Contact

Mr Martin Griffith P: +61 (02) 94760300

Availability

Services available to external clients

Scope of Accreditation

Switchmode Power Supplies

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM) AC current; DC current Direct measurement against a reference standard

D.C. ammeters

By the methods of -

WI.WC.33, WI.WC.34

A.C. ammeters

By the methods of -

WI.WC.37, WI.WC.38

D.C. ammeters

From 100 μA to 400 A

A.C. ammeters

From 10 Hz to 60 Hz at 10 mA to 100 A

Capability

with Calibration and Measurement Capability of -

D.C. ammeters

0.092% from 100 μA to 1 mA
0.25% from 1 mA to 10 mA
0.093% from 10 mA to 100 mA
0.22% from 100 mA to 1 A
0.19% from 1 A to 10 A
0.092% from 10 A to 400 A

A.C. ammeters

0.51% from 10 Hz to 5 kHz from 10 mA to 1 A
0.47% from 50 Hz to 60 Hz and at 400 Hz from 1 A to 20 A
0.41% from 50 Hz to 60 Hz from 20 A to 100 A

Digital multimeters (DMM); Voltmeters AC voltage; DC voltage Direct measurement against a reference standard

D.C. voltmeters

By the methods of -

WI.WC.31

A.C. voltmeters

By the methods of -

WI.WC.35

D.C. voltmeters

From 1 mV to 1000 V

A.C. voltmeters

From 10 mV to 120 V at 10 Hz to 100 kHz

From 120 V to 1000 V at 50 kHz to 60 kHz

Capability

with Calibration and Measurement Capability of -

D.C. voltmeters

0.57% from 1 mV to 10 mV
0.058% from 10 mV to 120 mV
0.013% from 0.12 V to 1000 V

A.C. voltmeters

From 10 mV to 120 V
0.41% from 10 Hz to 20 kHz
0.62% from 20 kHz to 50 kHz
1.21% from 50 kHz to 100 kHz
from 120 V to 1000 V
0.26% from 50 kHz to 60 kHz

Power supplies AC current; AC voltage; Active power; DC current; DC voltage Direct measurement against a reference standard Power supplies and power conditioners
Power supply equipment and systems
D.C. voltage
By the methods of -
WI.WT.31
A.C. voltage
By the methods of -
WI.WT.35
D.C. current
By the methods of -
WI.WT.33, WI.WT.34
A.C. current
By the methods of -
WI.WT.37, WI.WT.38
D.C. power and Active power
By the methods of -
 WI.WT.41

Capability

Power supplies and power conditioners
Power supply equipment and systems
with Calibration and Measurement Capability of -

D.C. voltage
0.57% from 1 mV to 10 mV
0.058% from 10 mV to 120 mV
0.013% from 0.12 V to 1000 V

A.C. voltage 
from 10 mV to 1000 V and 10 Hz to 100 kHz

from 10 mV to 120 V
0.41% from 10 Hz to 20 kHz
0.62% from 20 kHz to 50 kHz
1.21% from 50 kHz to 100 kHz
from 120 V to 1000 V
0.26% from 50 Hz to 60 Hz

D.C. current from 100 μA to 400 A
0.092% from 100 μA to 1 mA
0.25% from 1 mA to 10 mA
0.093% from 10 mA to 100 mA
0.22% from 100 mA to 1 A
0.19% from 1 A to 10 A
0.092% from 10 A to 400 A

A.C. current 
0.51% from 10 mA to 1 A from 10 Hz to 5 kHz
0.47% from 1 to 20 A from 50 Hz to 60 Hz and at 400 Hz
0.41% from 20 A to 100 A from 50 Hz to 60 Hz

DC power 
from 1 to 1000 V and 0.1 to 400 A (limited to 50kW)
with least uncertainties of measurement of -
0.62%
 
Active Power 
from 1 to 750 V and 0.1 to 100 A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz
0.66%


Watt meters Active power Direct measurement against a reference standard

By the methods of -

WI.WC.41

D.C. power

From 1 V to 1000 V and 0.1 A to 400 A (limited to 50 kW)

Active power

From 1 V to 750 V and 0.1 A to 100 A (limited to 50 kW) at Unity power -factor

Capability

with Calibration and Measurement Capability of -

D.C. power

0.62% from 1 to 1000V and 0.1 to 400A (limited to 50kW)

Active power

0.66% from 1 to 750V and 0.1 to 100A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz