National Association of Testing Authorities, Australia
Scope of Accreditation
Switchmode Power Supplies Pty Ltd
Site
Switchmode Power Supplies
Accreditation No.
16641
Site No.
17961
Date of Accreditation
24 Nov 2009
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Digital multimeters (DMM) | AC current; DC current | Direct measurement against a reference standard | D.C. ammeters By the methods of - WI.WC.33, WI.WC.34 A.C. ammeters By the methods of - WI.WC.37, WI.WC.38 | D.C. ammeters From 100 μA to 400 A A.C. ammeters From 10 Hz to 60 Hz at 10 mA to 100 A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - D.C. ammeters 0.092% from 100 μA to 1 mA A.C. ammeters 0.51% from 10 Hz to 5 kHz from 10 mA to 1 A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Digital multimeters (DMM); Voltmeters | AC voltage; DC voltage | Direct measurement against a reference standard | D.C. voltmeters By the methods of - WI.WC.31 A.C. voltmeters By the methods of - WI.WC.35 | D.C. voltmeters From 1 mV to 1000 V A.C. voltmeters From 10 mV to 120 V at 10 Hz to 100 kHz From 120 V to 1000 V at 50 kHz to 60 kHz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - D.C. voltmeters 0.57% from 1 mV to 10 mV A.C. voltmeters From 10 mV to 120 V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power supplies | AC current; AC voltage; Active power; DC current; DC voltage | Direct measurement against a reference standard | Power supplies and power conditioners Power supply equipment and systems D.C. voltage By the methods of - WI.WT.31 A.C. voltage By the methods of - WI.WT.35 D.C. current By the methods of - WI.WT.33, WI.WT.34 A.C. current By the methods of - WI.WT.37, WI.WT.38 D.C. power and Active power By the methods of - WI.WT.41 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Power supplies and power conditionersPower supply equipment and systems with Calibration and Measurement Capability of - D.C. voltage 0.57% from 1 mV to 10 mV 0.058% from 10 mV to 120 mV 0.013% from 0.12 V to 1000 V A.C. voltage from 10 mV to 1000 V and 10 Hz to 100 kHz from 10 mV to 120 V 0.41% from 10 Hz to 20 kHz 0.62% from 20 kHz to 50 kHz 1.21% from 50 kHz to 100 kHz from 120 V to 1000 V 0.26% from 50 Hz to 60 Hz D.C. current from 100 μA to 400 A 0.092% from 100 μA to 1 mA 0.25% from 1 mA to 10 mA 0.093% from 10 mA to 100 mA 0.22% from 100 mA to 1 A 0.19% from 1 A to 10 A 0.092% from 10 A to 400 A A.C. current 0.51% from 10 mA to 1 A from 10 Hz to 5 kHz 0.47% from 1 to 20 A from 50 Hz to 60 Hz and at 400 Hz 0.41% from 20 A to 100 A from 50 Hz to 60 Hz DC power from 1 to 1000 V and 0.1 to 400 A (limited to 50kW) with least uncertainties of measurement of - 0.62% Active Power from 1 to 750 V and 0.1 to 100 A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz 0.66% | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Watt meters | Active power | Direct measurement against a reference standard | By the methods of - WI.WC.41 | D.C. power From 1 V to 1000 V and 0.1 A to 400 A (limited to 50 kW) Active power From 1 V to 750 V and 0.1 A to 100 A (limited to 50 kW) at Unity power -factor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - D.C. power 0.62% from 1 to 1000V and 0.1 to 400A (limited to 50kW) Active power 0.66% from 1 to 750V and 0.1 to 100A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz |