National Association of Testing Authorities, Australia
Scope of Accreditation
EMC Technologies Pty Ltd
Site
Sydney Laboratory – EMC Test Laboratory
Accreditation No.
5292
Site No.
10854
Date of Accreditation
14 Aug 1995
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Manufactured Goods
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Electrical equipment approval and safety evaluation | Audio, video and similar electronic equipment; Information technology equipment | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 62368.1, IEC 62368-1 and EN 62368-1 excluding clause nos. 8.5.5, 10, G.5.2, G.15, M.8, S.5 and Annexes C, J, R and U | |
| Electrical appliances, coupling devices and accessories | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS/NZS 60695.2.11 AS/NZS 60695.10.2 AS/NZS 60695.11.5 |
||
| Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS/NZS 60335.1 IEC 60335-1 EN 60335.1 (excluding Annex N) , IP testing for IPX4 is limited to items that AS/NZS 60335.2.30, IEC 60335-2-30, EN 60335.2.30 |
|||
| Electrical machines and auxiliary apparatus; Electrical plugs, sockets, lead assemblies and related components; Lamps and lampholders (including LED-based lamps); Power adapters, low voltage power supply components, appliance transformers, power stabilisers and related items; Power tools - Electric | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS/NZS 3100 AS/NZS 3136 |
||
| Enclosures for electrical equipment | Degree of protection - IP rating | Not applicable |
AS 60529 IEC 60529 |
excluding IP5X, IP6X and IPX9 IP testing for IPX3 and IPX4 is limited to items that fit within a rotating tube with maximum radius of 400 mm |
|
| Laboratory and electromedical equipment | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS 61010.1, IEC 61010-1 EN 61010-1; IEC 61010-2-10 and EN 61010-2-10; IEC 61010-2-20 and EN 61010-2-20; IEC 61010-2-30 and EN 61010-2-30; IEC 61010-2-40 and EN 61010-2-40; IEC 61010-2-51 and EN 61010-2-51; IEC 61010-2-81 and EN 61010-2-81; IEC 61010-2-101 and EN 61010-2-101; IEC 61010-2-201 and EN 61010-2-201; AS/NZS 60601.1, IEC 60601-1, EN 60601-1 |
excluding clause 12 (other than 12.4 up to 45 GHz) and clause 13.2.3 (implosion of CRT tubes) of AS 61010.1,.IEC 61010-1 and EN 61010-1; and excluding defibrillation test to AS/NZS 60601.1, IEC 60601-1 and EN 60601-1 |
|
| Power adapters, low voltage power supply components, appliance transformers, power stabilisers and related items | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination |
AS/NZS 61558.1, IEC 61558-1, EN 61558-1 AS/NZS 61558.2.6, IEC 61558-2-6, EN 61558-2-6 AS/NZS 61558.2.16, IEC 61558-2-16, EN 61558-2-16 |
||
| Electromagnetic compatibility (EMC) - Emissions - Commercial | Airborne equipment | Conducted emissions; Radiated emissions | Not applicable |
RTCA DO160 F/G section 21 |
Conducted RF emissions 150 kHz to 150 MHz |
| Electrical and electronic products; Multimedia equipment; Power tools - Electric | Conducted emissions; Discontinuous disturbances; Disturbance power; Radiated emissions | Not applicable |
AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; CNS 13783-1; For unintentional and intentional emitters in the frequency range 9 kHz to 40 GHz -Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; -Intentional Radiators described in FCC Part 15, Subpart C using ANSI C63.10:2020 ; -Intentional Radiators described in FCC Part 15, Subpart E for U-NII devices without DFS, using ANSI C63.10:2020; KDB 789033 D02 General U-NII test procedure - new rules; KDB 558074 D01 DTS measurement guidance. ICES-003 For unintentional and intentional emitters in the frequency range 9 kHz to 40 GHz RSS-247; RSS-210 For unintentional and intentional emitters in the frequency range 9 kHz to 40 GHz RSS-GEN |
Reference to Radiated measurements performed in the 3 metre iOATS Semi Anechoic Chamber Room 3 |
|
| Electrical equipment for measurement, control and laboratory use | Conducted emissions; Radiated emissions | Not applicable |
AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; |
Excluding measurements below 2 kHz |
|
| Electrical lighting and similar equipment | Conducted emissions; Radiated emissions | Not applicable |
AS/NZS CISPR 15; CISPR 15; EN 55015 |
||
| Information technology equipment | Conducted emissions; Conducted telecommunications port emissions; Radiated emissions; Radio influence voltage measurement | AMN and voltage probe; ISN and current clamp |
AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; VCCI; CNS 13438; EN 55022 |
Reference to Radiated measurements performed in the 3 metre iOATS Semi Anechoic Chamber Room 3. Excluding capacitive voltage probe tests for telecommunications ports |
|
| Machine tools | Conducted emissions; Discontinuous disturbances; Mains harmonics and flicker; Radiated emissions | Not applicable |
AS/NZS CISPR 11; CISPR 11; EN 55011; |
||
| Maritime navigation equipment | Conducted emissions; Radiated emissions | Not applicable |
EN 60945 |
Excluding measurements below 2 kHz |
|
| Medical electrical equipment | Radiated emissions | Not applicable |
AS/NZS CISPR 11; CISPR 11; EN 55011; |
||
| Radio equipment | Conducted emissions; Radiated emissions | Not applicable |
ETSI EN 301 489-1 ETSI EN 301 489-3;ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; |
||
| Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted emissions; Radiated emissions | Not applicable |
EN 50121-3-1; EN 50121-3-2; EN 50121-4; |
||
| Electromagnetic compatibility (EMC) - Immunity - Commercial | Airborne equipment | Conducted disturbance; Conducted susceptibility; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Voltage spikes | Not applicable |
RTCA DO160 F/G Sections 20; |
|
| Components of fire, intruder and social alarm systems | Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Voltage short dips and interruptions | Not applicable |
EN 50130-4; |
||
| Electrical and electronic products; Power tools - Electric | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
AS/NZS CISPR 14.2; CISPR 14-2; EN 55014-2; |
||
| Electrical equipment for measurement, control and laboratory use | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
IEC 61326-1; EN 61326-1; |
||
| Electrical lighting and similar equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
EN 61547; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-9; EN 61000-4-9; AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11 |
||
| Gaming machines | Electrical fast transient; Electrostatic interference; Voltage short dips and interruptions | Not applicable | Australian/New Zealand Gaming Machine National Standard clauses 6.28 to 6.32 only | ||
| Information technology equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
AS/NZS CISPR 35 excluding clause 4.2.7; CISPR 35 excluding clause 4.2.7 ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2IEC 801-3; AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4; AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5; AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-9; EN 61000-4-9; IEC 61000-4-10; EN 61000-4-10; AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11 IEC 61000-4-12; AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16; IEC 61000-4-18; EN 61000-4-18 |
||
| Low voltage switchgear and control equipment | Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
EN 60947; |
||
| Machine tools | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000-6-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-9; EN 61000-4-9; AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11 |
||
| Medical electrical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
AS IEC 60601.1.2, IEC 60601-1-2; EN 60601-1-2; |
||
| Multimedia equipment | Common mode low frequency; Conducted disturbance; Conducted susceptibility; DC input power ripple; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Induced signal susceptibility; Magnetic effects; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Voltage spikes | Not applicable |
EN 55035 excluding clause 4.2.7; AS/NZS CISPR 35 excluding clause 4.2.7; CISPR 35 excluding clause 4.2.7 |
||
| Radio equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
ETSI EN 301 489-1; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; |
||
| Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable |
EN 50121-3-2; EN 50121-4; EN 51021-5; |
||
| Electromagnetic radiation exposure - Extremely low frequency (ELF) fields | Electricity grid installations; High voltage transformer equipment; Residential, commercial and light industrial environments | Broadband measurements of H-fields; Narrowband measurements of H-fields | Not applicable |
ARPANSA Radiation Protection Standard (RPS S-1); AS/NZS 2772.2 and NZS 2772.1; |
|
| Electromagnetic radiation exposure - Radiofrequency (RF) fields | Antennas; Microwave ovens; Rolling stock | Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields | Not applicable |
ARPANSA Radiation Protection Standard (RPS S-1); AS/NZS 2772.2 and NZS 2772.1; |
Broadband measurements of E-fields in the range 9 kHz to 60 GHz ; |
| Shielded enclosures | Attenuation performance | Not applicable |
MIL-STD-285 Rev. 1.8 |
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.
Accreditation No.
5292
Site No.
10854
Print date
27 Aug 2026