Territory Instruments

Site

Territory Instruments

Accreditation No.

20424

Site No.

24452

Date of Accreditation

27 Apr 2021

Address

15 Raphael Road
Winnellie, NT 820
Australia

territoryinstruments.com

Contact

Mr Stuart Kenny P: +61 (08) 89475450

Availability

Services available to external clients

Scope of Accreditation

Territory Instruments

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators AC current; AC voltage; DC current; DC voltage; Resistance Comparison with a reference standard; Direct measurement Industrial process calibrators only





Capability

With Calibration and Measurement Capability of -

DC Voltage
0.04% from 1mV to 100mV
0.02% above 100 mV up to 1000 V

DC Current
0.09% + 1 µA above 100uA to 1mA
0.2% above 1mA to 1A
0.4% above 1A to 10A

Resistance
0.05% from 10 Ω to 10 MΩ
0.65% above 10 MΩ to 100 MΩ


DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Voltmeters AC current; AC voltage; DC current; DC voltage; Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

DC Voltage
0.24% from 2 mV up to 20 mV
0.03% above 20 mV up to 200 mV
0.01% above 200 mV up to 20 V
0.02% above 20 V up to 1000 V

AC Voltage
from 3 mV to 33 mV
0.75% from 45 Hz to 100 kHz
1% above 100 kHz to 450k Hz

above 33 mV to 330 mV
0.06% from 45 Hz to 20 kHz
0.09% above 20 kHz to 50 kHz
0.52% above 50 kHz to 500 kHz

above 330 mV to 33 V
0.09% from 45 Hz to 50 kHz
0.47% above 50k Hz to 50 0kHz

above 33 V to 330 V
0.1% from 45 Hz to 50 kHz
0.25% above 50 kHz to 100 kHz

above 330 V to 1020 V
0.08% from 45 Hz to 8 kHz

DC Current
0.01% +0.2 µA from 0 to 330 μA
0.09% +0.2 µA above 330 μA to 20.5 A

AC Current
from 33 μA to 330 μA
0.7% from 10 Hz to 10k Hz

above 330 μA to 3.3 mA
1% + 4μA from 10 Hz to 45 Hz
0.4% above 45 Hz to 10 kHz

above 3.3mA to 33mA
1% + 4μA from 10 Hz to 45 Hz
0.08% above 45 Hz to 10 kHz
0.17% above 5 kHz to 10 kHz

above 33 mA to 330 mA
0.17% from 10 Hz to 20 Hz
0.09% above 20 Hz to 5 kHz
0.18% above 5 kHz to 10 kHz

above 330mA to 1.1A
0.2% from 10 Hz to 45 Hz
0.06% above 45 Hz to 1 kHz
0.6% above 1 kHz to 5 kHz
2.3% above 5 kHz to 10 kHz

above 1.1A to 3 A
0.85% from 10 Hz to 45 Hz
0.16% above 45 Hz to 1 kHz
0.06% above 1 kHz to 5 kHz
0.5% above 5 kHz to 10 kHz

above 3A to 11A
0.6% from 10Hz to 45Hz
0.09% above 45Hz to 1kHz
0.18% above 1kHz to 5kHz

above 11A to 20.5A
1.5% from 10 Hz to 45 Hz
0.12% above 45 Hz to 1 kHz
0.2% from 1 kHz to 5 kHz

Resistance
0.6% from 2 Ω to 33 Ω
0.04% above 33 Ω to 110 Ω
0.02% above 110 Ω to 1.10 MΩ
0.03% above 1.10 MΩ to 3.3 MΩ
0.06% above 3.3 MΩ to 11 MΩ
0.09% above 11 MΩ to 119 MΩ  

Insulation Resistance
0.7%  above 100 kΩ to 999.9 MΩ from 50 V to 5 kV
2.5%  above 999.9 MΩ to 10 GΩ from 50 V to 5 kV




Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges Gauge pressure Comparison with reference instrument MSA test methods 1 and 2

Capability

with Calibration and Measurement Capability of -
0.04 % of reading  or  40 Pa (whichever is greater) from -95 kPa to 100 kPa
0.04 % of reading above 100 kPa to 1 MPa
0.03% of reading above 1 MPa to 21 MPa
Pressure metrology - Pressure standards Pressure calibrators - Non-dead weight Gauge pressure Comparison with dead weight tester MSA Test method 1

Capability

with Calibration and Measurement Capability of -
0.04 % of reading or 40 Pa (whichever is greater) from -95 kPa to 100 kPa
0.04 % of reading above 100 kPa to 1 MPa
0.03% of reading above 1 MPa to 21 MPa

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.