National Association of Testing Authorities, Australia
Scope of Accreditation
SGS Australia Pty Ltd
Site
trading as SGS Radiation Services
Accreditation No.
2562
Site No.
18509
Date of Accreditation
16 Apr 2010
Address
10 / 585 Blackburn Road
Notting Hill, VIC 3168
Australia
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ionising radiation - Ionising radiation standards and equipment | Contamination monitoring instruments | Gamma activity | Direct measurement against a reference standard | In-house procedure CA 018 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of contamination monitoring instruments using wide area reference sources with Calibration and Measurement Capability of - 7% at 8.1 Bq/cm2 for 238Pu (large area detectors only), 7% at 660 Bq/cm2 for 238Pu 7% at 570 Bq/cm2 for 241Am 7% at 510 Bq/cm2 for 14C 7% at 220 Bq/cm2 for 99Tc 7% at 250 Bq/cm2 for 36Cl 7% at 180 Bq/cm2 for 90Sr/90Y and 7% at 120 Bq/cm2 for 129I | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Contamination monitoring instruments; Ionising radiation survey instruments | Air kerma rate (mGy/h); Ambient dose equivalent (H*(10) rate (mSv/h)); Exposure rate (mR/h, C/kg/h) | Direct measurement against a reference standard | In-house procedure CA 001 and CA019 | Calibration of ionising radiation survey instruments for exposure rate (mR/h), air kerma rate (mGy/h) and ambient dose equivalent (H*(10) rate (mSv/h)) and the corresponding integrated values (exposure, air kerma and ambient dose equivalent) for survey instruments with internal timers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Utilising 662 keV γ-rays in the air kerma rate range of 8 x 10-8 to 1.2 x 10-2 Gy/h using 137Cs sources of activity with Calibration and Measurement Capability of - 33% using a 370 MBq source, 6% using a 3.7 GBq source, 5% using a 41 GBq source, 5% using a 145 GBq source | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dosimeters | Personal dose equivalent and cumulative effective dose | Direct measurement against a reference standard | In-house procedure CA 010 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of electronic personal dosemeters for personal dose equivalent Hp(10) (mSv) |
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Ionising radiation - Dosimetry | Radiation contamination monitoring instruments | Response evaluation | Not applicable | In-house procedure CA 018 | |
Ionising radiation - Source characterisation | Isotopes and other sources of ionising radiation | Radionuclide source identification | 133Ba gamma ray point source; 137Cs gamma ray point source; 226Ra gamma ray point source; 232Th gamma ray point source; 241Am gamma ray point source; 60Co gamma ray point source | In-house procedure CA 018 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
2562
Site No.
18509
Print date