National Association of Testing Authorities, Australia
Scope of Accreditation
Trident Australia Pty Ltd
Site
Trident Australia Pty Ltd
Accreditation No.
15503
Site No.
16437
Date of Accreditation
04 Dec 2006
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers | Gauge pressure | Comparison with dead weight tester; Comparison with reference instrument | Pressure including test and vacuum gauges to MSA Test Method 2; Self indicating and electrical transducers with dc voltage or dc current output MSA Test Method 1 | 10 kPa to 276 MPa (40,000 psi) Self indicating and electrical transducers with dc voltage or dc current output | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With calibration and measurement capability of - 0.03% of reading or 0.005 kPa (whichever is greater) in the range of 10 kPa to 276 MPa (40,000 psi) |
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Hydrostatic pressure | Not applicable | AS 1180.5 Section 7 (1999), ISO 1402 Section 8.1 | up to 300 MPa |
Valves | Hydrostatic pressure; Leakage | Not applicable | API 527 section 4 | Up to 200 MPa | |
Leakage; Pneumatic pressure | Not applicable | API 527 sections 2 and 5 | Up to 137 MPa |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
15503
Site No.
16437
Print date