National Association of Testing Authorities, Australia
Scope of Accreditation
Ross Technology Consulting Pty Ltd ATF The Ross Consulting Trust - Trading as Utility Meter Verification Services
Site
UMVS Cleveland Laboratory
Accreditation No.
20883
Site No.
25077
Date of Accreditation
31 Mar 2021
Contact
Mr Doug Ross P: +61 0417205395
Availability
Services available to external clients
Scope of Accreditation
UMVS Cleveland Laboratory
ISO/IEC 17025 (2017)
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical measurement and test equipment | Electricity meters | Active energy; Reactive energy | Comparison with a reference standard | Accuracy tests and functional tests for no load and starting current of single and polyphase electricity meters by the methods; AS 62053 parts 21, 22, 23, 24; NMI NITP 14 National Instrument Test Procedures for Utility Meters including sampling clause 6 and verification test procedure clause 7; NMI M 6-1 Active-Energy Electricity Meters. Part 1: Metrological and Technical Requirements; AS/NZS 1284.13 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -Watt-hour meters at 50 Hz at power factor of 1.0 0.028% for currents from 10 mA to 20 mA and voltages 63.5 V to 240 V AC P-N Watt-hour meters at 50 Hz across power factors 1.0 to 0.5 leading and lagging currents 0.013% / cos Φ for currents from 20 mA to 100 A and voltages 63.5 V to 240V AC P-N Var-hour meters at 50 Hz across power factors 1.0 to 0.5 leading and lagging currents 0.035% / sin Φ for currents from 50 mA to 100 A and voltages 63.5 V to 240V AC P-N |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20883
Site No.
25077
Print date
23 Nov 2024
END OF SCOPE