Itron Australasia Pty Ltd

Site

Utility Meter Laboratory

Accreditation No.

14618

Site No.

14681

Date of Accreditation

20 Feb 2003

Address

8 Rosberg Road
Wingfield, SA 5013
Australia

itron.com

Contact

Mr Shames Ud-Din P: +61 (08) 81692500

Availability

Services conditionally available to external clients

Scope of Accreditation

Utility Meter Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Electricity meters; Watt meters Active energy Comparison with a reference standard

Calibration and verification of single phase Class 1 and three phase Class 1 direct connected production watt-hour meters including compliance with NMI NITP 14

Capability

with Calibration and Measurement Capability of -
(0.1/cosφ)% of reading for
Single phase meters at 240 V, 50 Hz and currents from 1 to 100 A (both positive flow and negative flow)
at unity PF and 0.5 PF (lag) and at 0.5 A at unity PF
and
Three phase meters at 240/415V, 50 Hz and currents from 1 to 100 A(both positive flow and negative flow)
at unity PF and 0.5 PF (lag) and at 0.5A at unity PF

Flow metrology - Flow measuring devices and systems Gas meters Minimum volume; Volume (and nominal flow rate) Comparison with a reference meter

Including verification of flow performance to AS 4647 section 4 and leak testing of domestic gas meters

Capability

with Calibration and Measurement Capability of -

0.46% of volume with a minimum test volume of 100 L for domestic gas flow meters using air at atmospheric conditions as the test fluid from 0.08 m³/h to 10 m³/h
0.27% of volume with a minimum test volume of 600 L for Commercial and industrial gas flow meters using air at atmospheric conditions as the test fluid from 3 m³/h to 60 m³/h

Flow metrology - Water flow measuring devices and systems Liquid meters Volume (and nominal flow rate) Comparison with a reference meter Including error of measurement for compliance with NMI NITP 14
and water tightness tests on water meters for compliance with AS 3565.1 with verification scale intervals up to 20 L

Capability

with Calibration and Measurement Capability of -
Water meters from 15 mm up to 150 mm bore diameter at flow rates from 5 L/h to 500 kL/h
0.15% of volume with a minimum test volume of 100 L
0.25% of volume with a minimum test volume of 10 L
0.45% of volume with a minimum test volume of 5 L

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.