Furmanite Australia Pty Ltd

Site

Valve Repair Workshop

Accreditation No.

19728

Site No.

22974

Date of Accreditation

06 Sep 2016

Address

18 Phillis Street
Wingfield, SA 5013
Australia

teaminc.com

Contact

Mr Kingsley Rowse P: +61 0434073812

Availability

Services available to external clients

Scope of Accreditation

Valve Repair Workshop

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Valves Seat leakage Not applicable

Seat tests to API 527, API 576 Clause 6.2.9.9, AS 1271 Clause 2.6.3

Up to 70 MPa 

Including tests in the field
Hydrostatic pressure; Pneumatic pressure Not applicable

AS1271 Clause 2.6.2

Up to 70 MPa 

Including tests in the field
Hydrostatic pressure; Pneumatic pressure; Seat leakage Not applicable

 API 6D Clauses 9.1, 9.2, 9.3, 9.4 and Annex H, API 598, 


Up to 70 MPa

Including tests in the field
Hydrostatic pressure; Pneumatic pressure; Set pressure Not applicable

Cold set pressure lift tests to API 576 Clause 6.2.9.8, AS 1271 Clause 3.4.2, AS 3788 Clauses 4.7.4.1, 4.7.5 and 4.7.6

Up to 70 MPa

Including tests in the field
Hydrostatic pressure; Pneumatic pressure; Set pressure Not applicable

In-situ set pressure lift tests to AS 1271 Clause 3.4.2, AS 3788 Clauses 4.7.4.1 and 4.7.6

Up to 70 MPa 

Including tests in the field

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.