Vipac Engineers and Scientists Ltd

Site

Victorian Laboratory

Accreditation No.

676

Site No.

1499

Date of Accreditation

12 Feb 1981

Address

Victorian Technology Centre, 275-283 Normanby Road
Port Melbourne, VIC 3207
Australia

vipac.com.au

Contact

Mr Benjamin Smith P: +61 (03) 96479700

Availability

Services available to external clients

Scope of Accreditation

Victorian Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Air conditioning and ventilation systems Air flow Not applicable ASHRAE 55
ASHRAE 70
ASHRAE 113
ASHRAE 130
ISO 5219
ISO 7730
AS 4740
ADC FD72
ARI 650
BS 4797 Part 1
Dampers Cyclic test; Dynamic closure; Leakage; Operation; Temperature degradation Not applicable UL 555
BS EN 1751
ISO 10294
AS 1682.1
 SS 333
Fans Air delivery; Air flow; Fan speed and power Not applicable

Air delivery, fan speed and power of electric circulating fans for household and similar use, excluding ceiling-type fans, to AS 2071-1984

Air flow measurement of fans and blowers using ASHRAE 51-75 nozzles, pitot tubes

Air flow measurement of gas fired ducted air heaters using ASHRAE 51-75 nozzles to AS 4556 and AG 106 (M.O.T.5.13.1-96)

BS 848 Part 1
ISO 5801

Air flow measurements with least uncertainties of measurement of -

6% from 0.01 to 1.0 m³/s using orifice plates;

4% from 0.05 to 1.0 m³/s using ASHRAE 51-75 nozzles;

10% from 2 to 5 m³/s using pitot tubes;

4% from 5 to 50 m³/s using pitot tubes;

10% from 0.2 to 2 m³/s using hot-wire anemometers;

5% from 2 to 10 m³/s using hot-wire anemometers;

20% from 0.2 to 20 m³/s using vane anemometers

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Acoustic performance evaluation of products Air conditioners and heat pumps; Air distribution products; Building materials and elements of construction Sound pressure level Not applicable

BS 4718 : 1971 (Clauses 2.3 and 3 only) ;

BS EN ISO 7235 (Clauses 6.2.1, 6.3 and 6.4 only)

BS 4856 Part 4 ;

ADC 1062 R4 ;

ARI 880 (Sound power components only) ;

ARI 885 (Sound power components only) ;

ARI 890 (Sound power components only) ;

ISO 3741 : 1999 (Broadband Noise measurements only) ;

ISO 3741 (Broadband Noise measurements only) ; 

AS 1217.2 : 1985 ;

AS 1277 : 1983

Static and dynamic insertion loss and generated noise level of air distribution system silencers, fan coil units, unit heaters and unit coolers

ISO 3741 over the frequency ranges :

- 63 Hz to 8 kHz in one third octave bands ;

- 63 Hz to 8 kHz in octave bands

Mechanical performance evaluation of components for building envelopes, framing and interior lining Door, window and skylight assemblies Air infiltration; Deflection; Operating force; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance Cyclic pressure; Static pressure AS/NZS 4420.1;
AS 2047 Section 2
Facade assemblies including interior and exterior cladding systems Air infiltration; Deflection; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance Cyclic pressure; Static pressure

including on-site tests to 

AS/NZS 4284 Sections 8.2, 8.3, 8.4, 8.5, 8.6, 8.8 and Appendices C, D, E (CSIRO SIROWET procedure);

 NCC Building Code of Australia (Volume 1, Section FV1 and Volume 2, Section V2.2.1)
Facade assemblies including interior and exterior cladding systems; Wall, floor and ceiling panels Water penetration resistance Field check - Spray including on-site tests to
AAMA 501.2

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.