National Association of Testing Authorities, Australia
Scope of Accreditation
AES Environmental
Site
Vokes Air Filtration Pty Ltd
Accreditation No.
1146
Site No.
1139
Date of Accreditation
07 Jan 1975
Contact
Mr Marc Young P: +61 1300550116
Availability
Services available to external clients
Scope of Accreditation
Vokes Air Filtration Pty Ltd
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of air control equipment | Air filters | Efficiency - Test dust No.1 | Photometric | AS 1324.2 Section 4 | |
Mass stabilisation | Gravimetric | AS 1324.2 Section 3 | |||
Gravimetric - Test dust No.4 | Gravimetric | AS 1324.2 Section 5 | |||
Initial resistance | Pressure differential | AS1324.2 Section 2 | |||
Air filters; Gas filters | Integrity of HEPA filter installations | Cold DOP | AS 1807.6 for compliance with AS 4260 Section 5.2 - Integrity testing of HEPA filters | Procedures in factory only. | |
Biological safety cabinets | Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4, NSF ANSI 49 N5.5 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | |
Gas tightness | Not applicable | AS 1807.25 (2004), AS 1807 clause 4.11 | for compliance with AS 2252.2 | ||
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5, NSF ANSI 49 N5.9 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Ultraviolet intensity | Not applicable | AS 1807.23 (2000), AS 1807 clause 4.10 | for compliance with AS 2252.2 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807 clause 4.1, NSF ANSI 49 N5.2 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Inward air velocity | Not applicable | AS 1807.21 (2000) AS 1807 clause 4.8, NSF ANSI 49 N5.3 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.2 | ||
Air barrier containment | Cold DOP; Potassium iodide (KI) discus | AS 1807.22 (2000), AS 1807.26 (2004), AS 1807 clause 4.9, 4.12 | for compliance with AS 2252.2 | ||
Sound level | Not applicable | AS 1807.20 (2000), AS 1807 clause 4.7, NSF ANSI 49 N5.11 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Clean rooms, pharmaceutical isolators and work stations | Recovery times | Not applicable | AS 1807.24 (2000), AS ISO 14644.3 Method B4 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room) | |
Air pressure | Not applicable | AS 1807.10, AS ISO 14644.3 Method B1 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Particle count in work zone | Automatic particle counter | AS 1807.8 (2000), AS ISO 14644.1 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Sound level | Not applicable | AS 1807.16, AS 1807.20 (2000), AS 1807 Clause 4.7 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room) | ||
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807.3 (2000), AS 1807 clause 4.1, AS ISO 14644.3 Method B2 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4, AS ISO 14644.3 Method B7 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Cytotoxic drug safety cabinets | Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807 clause 4.1 | for compliance with AS 2252.5 | |
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5 | for compliance with AS 2252.5 | ||
Ultraviolet intensity | Not applicable | AS 1807.23 (2000), AS 1807 clause 4.10 | for compliance with AS 2252.5 | ||
Sound level | Not applicable | AS 1807.20 (2000), AS 1807 clause 4.7 | for compliance with AS 2252.5 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.5 | ||
Particle count in work zone | Automatic particle counter | AS 1807.8 (2000), AS ISO 14644.1 | for compliance with AS 2252.5 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4 | for compliance with AS 2252.5 | ||
Fume cupboards and recirculating fume cabinets | Extraction performance | Face velocity | AS/NZS 2243.8 Appendix B; AS/NZS 2243.9 Appendix B | ||
Extraction performance | Smoke visualisation | AS/NZS 2243.8 Appendix A, AS/NZS 2243.9 Appendix A |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
1146
Site No.
1139
Print date
19 Dec 2024
END OF SCOPE