National Association of Testing Authorities, Australia
Scope of Accreditation
Presio Pty Ltd
Site
WA Operations
Accreditation No.
20990
Site No.
25227
Date of Accreditation
12 May 2022
Contact
Mr Paul Newbound P: +61 0419850996
Availability
Services available to external clients
Scope of Accreditation
WA Operations
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Hydrostatic pressure | Not applicable | ISO 1402 Section 8.1, ISO 10380 Section 5.3 | Up to 260 MPa including on-site testing. |
Piping | Pneumatic pressure | Not applicable | AS 4037 Sections 18 and 19.1; AS 4041 Sections 6.6, 6.8.1 and 6.9; ASME B31.3 Section 345.5; AS/NZS 5601.1 Appendix E | Up to 100 MPa including on-site testing. | |
Hydrostatic pressure | Not applicable | AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7, AS/NZS 1462.8 Section 7.1.3, AS/NZS 1477 Section 3.3.6, AS/NZS 2280 Section 4 and Appendix F, AS/NZS 4058 Sections 4.4 and 4.5, ASME B31.3 Section 345.4, ISO 14692-4 Section 4.6.2 | Up to 260 MPa including on-site testing. | ||
Pressure vessels | Pneumatic pressure | Not applicable | API 650 Sections 7.3.5 and 7.3.8, AS 1210 Section 5.11, AS 1692 Section 2.8.3, AS 4037 Section 18 | Up to 100 MPa including on-site testing. | |
Hydrostatic pressure | Not applicable | API 620 Sections 7.18 and 7.19, API 650 Sections 7.3.6 and 7.3.7, AS 1210 Section 5.10, AS 1692 Section 2.8.2, AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7 | Up to 260 MPa including on-site testing. | ||
Valves | Hydrostatic pressure; Leakage rate; Re-seating pressure; Seat leakage; Set pressure | Not applicable | API 526 Section 9, API 527 Section 4, AS 1271 Section 2.6 | Up to 260 MPa including on-site testing. AS 1271 Section 2.6 to ensure compliance with AS 1271 Section 3.4. | |
Leakage rate; Pneumatic pressure; Re-seating pressure; Seat leakage; Set pressure | Not applicable | API 526 Section 9, API 527 Sections 2 and 5, API 620 Section 9, AS 1271 | Up to 100 MPa including on-site testing. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20990
Site No.
25227
Print date
24 Nov 2024
END OF SCOPE