National Association of Testing Authorities, Australia
Scope of Accreditation
Veerde Pty Ltd trading as Wagner Pipeline Testing
Site
Wamuran Laboratory
Accreditation No.
15379
Site No.
16081
Date of Accreditation
23 Mar 2006
Contact
Mr Jacob Jones P: +61 (07) 54966715
Availability
Services available to external clients
Scope of Accreditation
Wamuran Laboratory
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of water and sewer pipelines | Sewer maintenance chamber structures; Sewer pipelines | Ovality; Vacuum pressure | Not applicable | Water Services Association of Australia WSA 02 Sections 21.4.2, 21.4.5, 21.6; Water Services Association of Australia WSA 06 Sections 41.5.2.1, 41.5.3 | to -90 kPa |
Sewer pipelines; Water pipelines | Closed circuit television (CCTV) visual examination | Not applicable | Water Services Association of Australia WSA 05 Appendix J | ||
Water pipelines | Hydrostatic pressure | Not applicable | AS 2419.1 (2017) Appendix P, AS/NZS 2566.2 clauses 6.3.4.1 and 6.3.4.2 and Appendices M4 and M5, Water Services Association of Australia WSA 01 Sections 2.13.5.1, 2.13.5.3, Water Services Association of Australia WSA 03 Section 19.4 | leakage testing in the range 1 to 20 l/min from 250 kPa to 2500 kPa | |
Sample collection | Water pipelines | Collection of water samples in conjunction with pressure testing of pipelines | Not applicable | AS 2031, AS/NZS 5667.1, in-house method W243/1 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
15379
Site No.
16081
Print date
08 Dec 2024
END OF SCOPE