National Association of Testing Authorities, Australia
Scope of Accreditation
WIKA Australia Pty Ltd
Site
WIKA AUSTRALIA Brisbane Laboratory
WIKA Australia Pty Ltd
Accreditation No.
21327
Site No.
25683
Date of Accreditation
25 Mar 2024
Contact
Dr Yayang Tan P: +61 0411183417
Availability
Services available to external clients
Scope of Accreditation
WIKA AUSTRALIA Brisbane Laboratory
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure metrology - Pressure and vacuum measuring equipmentincluding on-site calibrations | Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges | Gauge pressure | Comparison with dead weight tester; Comparison with reference instrument | MSA Test Method 1 MSA Test Method 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrationswith Calibration and Measurement Capability of - 0.2% of reading or 200 Pa whichever is greater from -100 kPa to 500 kPa 0.3% of reading above 500 kPa to 700 kPa 0.1% of reading above 700 kPa to 15000 kPa 0.03% of reading above 15000 kPa to 60000 kPa 0.05% of reading above 60000 kPa to 120000 kPa. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Bimetallic systems; Digital temperature measuring systems; Filled metal systems; Vapour pressure thermometers | Temperature | Comparison with a reference standard | WI 1.4.12 & 1.4.13 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capabilities of -Digital temperature indicator systems 0.35 ºC above -30 ºC to 0 ºC, 0.05 ºC at 0 ºC, 0.35 ºC above 0 ºC to 150 ºC. Vapour pressure thermometers, Filled metal and Bimetallic systems 1 ºC from -30 ºC to 150 ºC |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21327
Site No.
25683
Print date
23 Nov 2024
END OF SCOPE