National Association of Testing Authorities, Australia
Scope of Accreditation
WIKA Australia Pty Ltd
Site
WIKA Australia Pty Ltd
Accreditation No.
410
Site No.
403
Date of Accreditation
28 Feb 1963
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure metrology - Pressure and vacuum measuring equipment | Manometers | Gauge pressure | Comparison with reference instrument | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Mercury, digital and other liquid manometers with Calibration and Measurement Capability of - 0.1% of reading or 0.8 Pa (whichever is greater) from - 100 kPa to 210 kPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure and vacuum measuring equipmentincluding on site calibrations | Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges | Absolute pressure; Gauge pressure | Comparison with dead weight tester; Comparison with reference instrument | Pressure gauges and vacuum gauges including test gauges to the methods of AS 1349, and MSA Test Method 2; Pressure transducers - Self indicating and electrical transducers with dc voltage, dc current or resistance outputs by the methods of MSA Test Method 1; Pressure Calibrators and Pressure recorders by the methods of MSA Test Method 1 or 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Absolute pressure0.008% of reading or 6 Pa (whichever is greater) from 40 Pa to 120 MPa Gauge pressure 0.008% of reading or 0.8 Pa (whichever is greater) from -100 kPa to 100 kPa 0.006% of reading above 100 kPa to 5 000 kPa 0.008% of reading above 5 MPa to 20 MPa 0.007% of reading above 20 MPa to 120 MPa 0.08% of reading above 120 MPa to 260 MPa 0.1% of reading above 260 MPa to 350 MPa On-site calibrations 0.1 % of reading or 0.8 Pa (whichever is greater) from -100 kPa to 120 MPa 0.2 % of reading above 120 MPa to 350 MPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure standards | Pressure calibrators - Non-dead weight | Absolute pressure; Gauge pressure | Comparison with dead weight tester; Comparison with reference instrument | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Absolute pressure | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Bimetallic systems; Digital temperature measuring systems; Filled metal systems; Liquid in glass (LIG) thermometers; Metallic resistance thermometers; Temperature loggers - Single and multi-channel; Vapour pressure thermometers | Temperature | Measurement against reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Metallic resistance thermometers 0.05 ºC from -50 ºC to -35 ºC 0.03 ºC above -35 ºC to 150 ºC 0.05 ºC above 150 ºC to 200 ºC; Liquid-in-glass thermometers Vapour pressure thermometers, Filled metal and Bimetallic systems Digital temperature indicator systems, Temperature Loggers (external sensor) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature standards and reference equipment | Dry block calibrators | Temperature | Direct measurement using a reference standard | from -50 ºC to 400ºC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.05 ºC from -50 ºC to 250 ºC 0.2 ºC from 250 ºC to 400 ºC |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.