National Association of Testing Authorities, Australia
Scope of Accreditation
Bullivants Pty Limited
Site
Wollongong Laboratory
Accreditation No.
369
Site No.
1229
Date of Accreditation
14 Dec 1976
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of load handling, rigging and tensioning systems | C-hooks | Proof load | Not applicable | AS 4991 | 0.5 to 3,000 kN using horizontal test bed |
Chain slings | Proof load | Not applicable | AS 3775.1; AS 3775.2 Section 7 | 0.5 to 3,000 kN using horizontal test bed | |
Eye hooks | Proof load | Not applicable | AS 2317.1 | 0.5 to 3,000 kN using horizontal test bed | |
Fittings | Proof load | Not applicable | AS 4991 | 0.5 to 3,000 kN using horizontal test bed | |
Lifting and spreader beams | Proof load | Not applicable | AS 4991 | 0.5 to 3,000 kN using horizontal test bed | |
Shackles | Proof load | Not applicable | AS 2741 | 0.5 to 3,000 kN using horizontal test bed | |
Shank hooks | Proof load | Not applicable | AS 3777 | 0.5 to 3,000 kN using horizontal test bed | |
Sheave blocks | Proof load | Not applicable | AS 2089 | 0.5 to 3,000 kN using horizontal test bed | |
Swivels | Proof load | Not applicable | AS 2318 | 0.5 to 3,000 kN using horizontal test bed | |
Synthetic fibre roundslings | Breaking load; Proof load | Not applicable | AS 4497 | 0.5 to 3,000 kN using horizontal test bed (Proof Load) 19.61 to 3,000 kN using horizontal test bed (Break Load) 5 to 250 kN using portable load cell 4 to 245 kN onsite testing using portable load cell | |
Synthetic webbing flat slings | Breaking load; Proof load | Not applicable | AS 1353.1, AS 3585 | 0.5 to 3,000 kN using horizontal test bed (Proof Load) 19.61 to 3,000 kN using horizontal test bed (Break Load) 5 to 250 kN using portable load cell 4 to 245 kN onsite testing using portable load cell | |
Wire rope | Breaking load | Measured breaking force | AS 2759, AS 3569 clause 7.4.1 Method 1 | 19.61 to 3,000 kN using horizontal test bed 5 to 250 kN using portable load cell 1 to 300 kN onsite testing using portable load cell | |
Wire rope slings | Proof load | Not applicable | AS 1666.1; AS 1666.2 Section 9 and Appendix C | 0.5 to 3,000 kN using horizontal test bed |