National Association of Testing Authorities, Australia
Scope of Accreditation
Aegis Safety Pty Ltd
Site
Aegis Sales & Service
Accreditation No.
20700
Site No.
24839
Date of Accreditation
12 Jul 2021
Contact
Mr Stephen Colhoun P: +61 (07) 38651139
Availability
Services available to external clients
Scope of Accreditation
Aegis Sales & Service
ISO/IEC 17025 (2017)
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Pressure transducers; Vacuum gauges | Gauge pressure | By pressure calibrator; Comparison with dead weight tester | MSA Test Method 1 and 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrationsWith Calibration and Measurement Capacity of- 0.12% of reading or 8 Pa (whichever is higher) from-90 kPa to 500 kPa 0.05% of reading above 500 kPa to 70 MPa Onsite 0.3% of reading or 8 Pa (whichever is higher) from -90 kPa to 500 kPa 0.25% of reading above 500 kPa to 70 MPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Digital temperature measuring systems; Temperature loggers - Single and multi-channel | Temperature | Comparison with a reference standard | CAL-TE001 Calibration of Digital Thermometers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrationsWith Calibration and Measurement Capability of - 0.12 ºC from -90 ºC to below -20 ºC 0.08 ºC from -20 ºC to below 150 ºC 0.12 ºC from 150 ºC to 300 ºC On-site 0.15 ºC from -90 ºC to below -20 ºC 0.10 ºC from -20 ºC to below 150 ºC 0.20 ºC from 150 ºC to 300 ºC |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20700
Site No.
24839
Print date
26 Nov 2024
END OF SCOPE