Australian Standards Laboratory

Accreditation No.

411

Site No.

404

Date of Accreditation

08 Mar 1963

Address

Unit 1, 9 Bearing Road
Seven Hills , NSW 2147
Australia

ciscientific.com

Contact

Mr Jurgen Cyrulla P: +61 (02) 98384488

Availability

Services available to external clients

Scope of Accreditation

Australian Standards Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Dimensional metrology - Engineering equipment and precision instruments Centrifuges Rotational speed Comparison with a reference standard by differential measurement In-house method CY 20821

Capability

including on-site calibration

With Calibration and measurement capability of -

1.2 rpm from 10 to 900 rpm
2 rpm above 900 to 5000 rpm
0.02% of reading or 3 rpm (whichever is greater) above 5000 to 99 900 rpm

Mass - Determination of mass and calibration of weighing devices Mass standards Mass Gravimetric measurement against reference mass

Capability

With Calibration and measurement capability of-

3 µg from 1mg to 20 mg
4 µg from above 20 mg up to 50 mg
5 µg from above 50 mg up to 500 mg
6 µg from above 500 mg up to 1 g
7 µg from above 1 g up to 2 g
10 µg from above 2 g up to 5 g
25 µg from above 5 g up to 10 g
30 µg above 10 g up to 20 g
40 µg above 20 g up to 50 g
60 µg from above 50 g up to 100 g
0.11 mg from above 100 g up to 200 g
0.3 mg from above 200 g up to 500 g
0.6 mg from above 500 g up to 1 kg
2.5 mg from above 1 kg up to 2 kg
20 mg from above 2 kg up to 10 kg
0.2 g from above 10 kg up to 20 kg 

0.02 kg from above 20 kg up to 250 kg
0.05 kg from above 250 kg up to 500 kg
0.1 kg from above 500 kg up to 1000 kg


Mass - Determination of mass and calibration of weighing devicesincluding on site calibrations Industrial weighing devices Mass Gravimetric measurement against reference mass

Capability

Including on site calibrations

With Calibration and measurement capability of-

1 in 104 or 1 mg (whichever is greater) up to 3000 kg

Laboratory weighing devices; Precision laboratory balances Mass Gravimetric measurement against reference mass

Capability

Including on site calibrations

With Calibration and measurement capability of-

1 in 106 or 4 ug (whichever is greater)  up to 0.5 g
6 in 106 above 0.5 g up to 1 g
4 in 106 above 1 g up to 2 g
2 in 106 above 2g up to 5g
3 in 106 above 5 g up to 10 g
2 in 106 above 10 g up to 20 g
1 in 106 above 20 g up to 1 kg
4 in 106 above 1 kg up to 10 kg
1 in 105 above 10 kg up to 20 kg

Temperature metrology - Ancillary temperature measuring equipment Multi-channel thermocouple data recorders; Process calibrators Volt to temperature conversion Direct measurement by electrical input

Capability

With Calibration and measurement capability of-

0.2 °C from -100 °C to 500 °C

0.3 °C from 500 °C to 1100 °C

Temperature metrology - Temperature measuring equipment Digital temperature measuring systems Temperature Measurement against reference standard

Capability

With Calibration and measurement capability of-

0.4 °C from -80 °C to 250 °C

0.6 °C from 250 °C to 500 °C

2.5 °C from 500 °C to 1100 °C

Temperature metrology - Verification of controlled enclosures Autoclaves and sterilising ovens; Baths; Freezers; Furnaces; Incubators; Ovens Gradient; Spatial uniformity Direct temperature measurement AS 2853

Capability

With Calibration and measurement capability of -

0.9 °C in the range from 0 °C to 250 °C for Ovens and Furnaces

2.6 °C in the range from 250 °C to 1100 °C for Ovens and Furnaces

0.9 °C in the range from -40 °C to 100 °C for Incubators

0.8 °C in the range from 100 °C to 130 °C for Autoclaves and sterilising ovens

1 °C in the range from 131 °C to 160 °C for Autoclaves and sterilising ovens

1 °C in the range from -80 °C to -16 °C for Industrial freezers

0.9 °C in the range from -15 °C to ambient for Industrial freezers

0.8 °C in the range from 0 °C to 130 °C for Baths

Torque - Torque measuring and testing equipment Torque wrenches Torque Comparison with a reference standard ISO 6789.2 and in house method 5.23

Capability

With Calibration and Measurement Capability of -
1.2% from 1.25 Nm to 1500 Nm
Volume and density - Determination of density Alcohol meters; Apparent density (draft survey) hydrometers; Bark hydrometer; Baume hydrometers; Brix hydrometers; Density hydrometers; Soil (colloidal solution) hydrometers; Specific gravity hydrometers Baume; Brix; Percentage (%) alcohol by volume; Specific gravity; g/L Hydrostatic weighing

Capability

With Calibration and measurement capability of -
1/3 of the smallest scale division in the range 0 to 2.0 g/ml for Density Hydrometers;
1/3 of the smallest scale division in the range 0.990 to 1.040 kg/L for Apparent Density Hydrometers;
1/3 of the smallest scale division in the range -5 to +60 g/l for Soil Hydrometers;
1/3 of the smallest scale division in the range 0 to 90º Bx for Brix Hydrometers;
1/3 of the smallest scale division in the range 0 to 80º Bk for Bark Hydrometers;
1/3 of the smallest scale division in the range 0 to 90º Be for Baume Hydrometers;
1/3 of the smallest scale division in the range 0.6 to 2.0 for Specific Gravity Hydrometers;
1/3 of the smallest scale division in the range 0 to 100% for Alcohol Hydrometers
Volume and density - Laboratory volumetric glassware and measures Piston operated volumetric apparatus (POVA) Volume Gravimetric by the method of ISO 8655 and in house method 5.19

Capability

With Calibration and Measurement Capability of -
0.034 µL from 1 µL to 10 µL
0.06 µL above 10 µL to 20 µL
0.07 µL above 20 µL to 50 µL
0.13 µL above 50 µL to 100 µL
0.15 µL above 100 µL to 200 µL
0.43 µL above 200 µL to 500 µL
1.1 µL above 500 µL to 1000 µL
3.7 µL above 1000 µL to 2500 µL
6.6 µL above 2500 µL to 5000 µL
11.0 µL above 5000 µL to 10000 µL