National Association of Testing Authorities, Australia
Scope of Accreditation
Calibration & Quality Solutions
Site
Calibration Laboratory
Accreditation No.
21634
Site No.
26056
Date of Accreditation
21 Jan 2026
Contact
Mr Tarin Glazier P: +61 0406615086
Availability
Services available to external clients
Scope of Accreditation
Calibration Laboratory
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensional metrology - Engineering equipment and precision instruments | Dial gauges; Electronic length gauges | Length measurements | Direct measurement against a reference standard | Including compliance with AS 2103-1978 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrations.With Calibration and Measurement Capability of- 1.9 µm from 5 µm to 50 mm 9.4 µm above 50 mm to 100 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensional metrology - Engineering equipment and precision instruments | Electronic calipers; Vernier calipers | Length measurements | Direct measurement against a reference standard | Including compliance with JIS B 7507 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -19 µm from 25 mm to 300 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensional metrology - Engineering equipment and precision instruments | Extensometers | Length measurements | Direct measurement against a reference standard | Including compliance with AS 1545 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including onsite calibrationsWith Calibration and Measurement Capability of- (1.2 + 0.5L) μm where L is the extension in mm from 0.05 mm up to 25 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Force metrology - Force measuring and testing equipment | Compression and universal machines in compression; Hydraulic rams and jacks; Load cells; Tension and universal machines in tension | Force in compression; Force in tension | Comparison measurement with reference load cell; Gravimetric measurement with reference mass | AS 2193 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrations.With Calibration and Measurement Capability of - 0.18% of reading for Class AA 0.01 kN to 10 kN in Tension 0.25% of reading for Class A 0.01 kN to 10 kN in Tension 0.18% of reading for Class AA 0.01 kN to 1 KN in Compression 0.18% of reading for Class AA 1.618 kN to 400 kN in Compression 0.25% of reading for Class A 0.01 kN to 2 MN in Compression | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Mass - Determination of mass and calibration of weighing devices | Industrial weighing devices; Precision laboratory balances | Mass | Gravimetric measurement against reference mass | NMI Monograph 4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on site calibrationswith Calibration and Measurement Capability of - Precision laboratory balances 120 μg above 1 g to 20 g 170 μg above 20 g to 100 g 280 μg above 100 g to 200 g 420 μg above 200 g to 300 g Industrial weighing devices 1.7 mg above 300 g to 1 kg 12 mg above 1 kg to 5 kg 18 mg above 5 kg to 10 kg 110 mg above 10 kg to 35 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges | Gauge pressure | Comparison with reference instrument | MSA Test Method 1 MSA Test Method 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrations.With Calibration and Measurement Capability of - 0.38% of reading from 50 kPa to 7000 kPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21634
Site No.
26056
Print date
23 Jan 2026