National Association of Testing Authorities, Australia
Scope of Accreditation
Trilab Pty Ltd
Site
Calibration Laboratory
Accreditation No.
9926
Site No.
18871
Date of Accreditation
22 Feb 2010
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensional metrology - Engineering equipment and precision instruments | Dial gauges | Length measurements | Direct measurement against a reference standard | For compliance with AS 2103-1978 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 3.6 μm above 25 mm to 100 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Extensometers | Length measurements | Direct measurement against a reference standard | For compliance with AS 1545 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Test sieves | Length measurements | Direct measurement against a reference standard | AS 1152(1993), ISO 3310-1, ISO 3310-2 and ASTM E11 | Wire woven and perforated plate sieves with a minimum aperture 32 μm to | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vernier calipers | Length measurements | Direct measurement against a reference standard | For compliance with JIS B 7507 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -17 μm for linear measurements from 25 mm up to 300 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Force measuring and testing equipment | Falling weight deflectometer | Load cell and sensor gains (deflection) | Comparison with a reference standard | TP-BF-StB-Part-B 8.4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.16% of reading for force from 1 kN to 16 kN 0.008 mm for deflection from -2.0 mm to +2.0 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Force measuring and testing equipmentincluding on-site calibrations | Compression and universal machines in compression; Hydraulic rams and jacks; Load cells; Load measuring rings; Tension and universal machines in tension | Force in compression; Force in tension | Comparison measurement with reference load cell; Gravimetric measurement with reference mass | AS 2193 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrations 0.15% of reading for Class AA 0.01kN to 100 kN in Tension 0.25% of reading for Class A 0.01 kN to 100 kN in Tension 0.16% of reading for Class AA 0.01 kN to 1.5 MN in Compression | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Hardness standards and equipment | Rubber bases | Rubber hardness | Direct force and length measurement | AS 1289.3.1.1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 1 IRHD for rubber hardness | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mass - Determination of mass and calibration of weighing devices | Industrial weighing devices | Mass | Gravimetric measurement against reference mass | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on site calibrationswith Calibration and Measurement Capability of - 1.5 mg above 300 g up to and including 1 kg 6 mg above 1 kg up to and including 5 kg 25 mg above 5 kg up to and including 20 kg 35 mg above 20 kg up to and including 30 kg 150 mg above 30 kg up to and including 60 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Precision laboratory balances | Mass | Gravimetric measurement against reference mass | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on site calibrationswith Calibration and Measurement Capability of - 40 μg above 1 g up to and including 20 g 100 μg above 20 g up to and including 100 g 200 μg above 100 g up to and including 200 g 300 μg above 200 g up to and including 300 g | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure and vacuum measuring equipmentincluding on site calibrations | Pressure gauges; Pressure transducers | Gauge pressure | By pressure calibrator | MSA Test Method 1 | Pressure gauges: Including on-site calibration to MSA Test Method 1 Pressure transducers: Including on-site calibration of self-indicating transducers | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrations With Calibration and Measurement Capability of- 0.35% or 0.15 kPa (whichever is greater) from 50 kPa to 60 MPa ( Pressure Transducers) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
9926
Site No.
18871
Print date
26 Dec 2024