Victorian Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators AC current; AC voltage; DC current; DC voltage; Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

D.C. voltage

3.9 µV/V + 380 nV from 0  to 200 mV

3.3 µV/V + 820 nV from 200 mV to 2 V

3.5 µV/V + 4. 7µV from 2 V to 20 V

5.3 µV/V + 61 µV from 20 V to 200 V

5.2 µV/V + 740 µV from 200 V to 1000 V

A.C. voltage

From 2.0 mV to 200 mV       

130 µV/V + 11 µV from 10 Hz to 40 Hz

140 µV/V + 5.7µV from 40 Hz to 100 Hz

130 µV/V + 4.8 µV from 100 Hz to 2 kHz

150 µV/V + 5.9 µV from 2 kHz to 10 kHz

320 µV/V + 9 µV from 10 kHz to 30 kHz

870 µV/V + 20 µV from 30 kHz to 100 kHz

From 200 mV to 2 V      

140 µV/V + 35 µV from 10 Hz to 40 Hz

120 µV/V + 36µV from 40 Hz to 100 Hz

120 µV/V + 20 µV from 100 Hz to 2 kHz

150 µV/V + 22 µV from 2 kHz to 10 kHz

230 µV/V + 40 µV from 10 kHz to 30 kHz

530µV/V + 190 µV from 30 kHz to 100 kHz

2.4mV/V + 1.9 mV from 100 kHz to 300 kHz

8.6 mV/V + 19 mV from 300 kHz to 1 MHz

From 2 V to 20 V

96 µV/V + 410 µV from 10 Hz to 40 Hz

81 µV/V + 300 µV from 40 Hz to 100 Hz

67 µV/V + 280 µV from 100 Hz to 2 kHz

110 µV/V + 260 µV from 2 kHz to 10 kHz

200 µV/V + 430 µV from 10 kHz to 30 kHz

510 µV/V + 1.9 mV from 30 kHz to 100 kHz

2.4 mV/V + 19 mV from 100 kHz to 300 kHz

8.5 mV/V + 190 mV from 300 kHz to 1 MHz

From 20 V to 200 V  

94 µV/V + 4.5 mV from 10 Hz to 40 Hz

78 µV/V + 3.7 mV from 40 Hz to 100 Hz

65 µV/V + 3.2 mV from 100 Hz to 2 kHz

98 µV/V + 3.5 mV from 2 kHz to 10 kHz

200 µV/V + 4.8 mV from 10 kHz to 30 kHz

510 µV/V + 19 mV from 30 kHz to 100 kHz

2.4 mV/V + 190 mV from 100 kHz to 300 kHz

From 200 V to 1 kV 

110 µV/V + 31 mV from 10 Hz to 40 Hz

150 µV/V + 23 mV from 40 Hz to 10 kHz


D.C. current

12 µA/A + 0.55 nA from 10 µA to 200 µA

13 µA/A + 4.8 nA from 200 µA to 2 mA

14 µA/A + 44 nA from 2 mA to 20 mA

45 µA/A + 1 µA from 20 mA to 200 mA

180 µA/A + 15 µA from 200 mA to 2 A

390 µA/A + 690 µA from 2 A to 20 A


A.C. current

From 100 μA to 200 µA
480 µA/A + 21 nA from 10 Hz to 10 kHz

From 200 µA to 2 mA       
280 µA/A + 210 nA from 10 Hz to 10 kHz

From 2 mA to 20 mA        
290 µA/A + 2.1 µA from 10 Hz to 10 kHz
From 20 mA to 200 mA 
270 µA/A + 21 µA from 10 Hz to 10 kHz 

From 200 mA to 2 A 

560 µA/A + 210 µA from 10 Hz to 2 kHz

560 µA/A + 500 µA from 2 kHz to 10 kHz

From 2 A to 20 A       

700 µA/A + 2.3 mA from 10 Hz to 2 kHz

1.9 mA/A + 4.3 mA from 2 kHz to 5 kHz


Resistance

2.1 µΩ/Ω + 60 µΩ from 0 Ω up to 2 Ω

7.6 µΩ/Ω + 60 µΩ from 2 Ω to 20 Ω

7.3 µΩ/Ω + 170 µΩ from 20 Ω to 200 Ω

7.5 µΩ/Ω + 1.2 mΩ from 200 Ω to 2000 Ω

7.5 µΩ/Ω + 10 mΩ from 2000 Ω to 20 kΩ

7.3 µΩ/Ω + 160 mΩ from 20 kΩ to 200 kΩ

8.7 µΩ/Ω + 3.1 Ω from 200 kΩ to 2 MΩ

18 µΩ/Ω + 140 Ω from 2 MΩ to 20 MΩ

130 µΩ/Ω + 9.8 kΩ from 20 MΩ to 200 MΩ

1.4 mΩ/Ω + 540 kΩ from 200 MΩ to 1GΩ





DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM); Ohm meters; Voltmeters AC current; AC voltage; DC current; DC voltage; Resistance Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

D.C. voltage

5.5 µV/V + 720 nV from 25 μV to 22 mV

6.9 µV/V + 690 nV from 22 mV to 220 mV

6.2 µV/V + 980 nV from 220 mV to 2.2 V

6.3 µV/V + 5.5 µV from 2.2 V to 22 V

7 µV/V + 78 µV from 22 V to 220 V

8.7 µV/V + 440 µV from 220 V to 1000 V

A.C. voltage

From 220 μV to 2.2 mV

520 µV/V + 4 µV from 10 Hz to 20 Hz

310 µV/V + 3.9 µV from 20 Hz to 40 Hz

240 µV/V + 3.9 µV from 40 Hz to 20 kHz

64 0µV/V + 3.8 µV from 20 kHz to 50 kHz

920 µV/V + 6.2 µV from 50 kHz to 100 kHz

From 2.2 mV to 22 mV       

470 µV/V + 4.9 µV from 10 Hz to 20 Hz

200 µV/V + 4.9 µV from 20 Hz to 40 Hz

120 µV/V + 4.9 µV from 40 Hz to 20 kHz

340 µV/V + 4.9 µV from 20 kHz to 50 kHz

750 µV/V + 6.6 µV from 50 kHz to 100 kHz

From 22 mV to 220 mV      

480 µV/V + 13 µV from 10 Hz to 20 Hz

210 µV/V + 7.5 µV from 20 Hz to 40 Hz

130 µV/V + 7.2 µV from 40 Hz to 20 kHz

300 µV/V + 7.8 µV from 20 kHz to 50 kHz

710µV/V + 24µV from 50 kHz to 100 kHz

910µV/V + 23µV from 100 kHz to 300 kHz

From 220 mV to 2.2 V

470 µV/V + 78 µV from 10 Hz to 20 Hz

150 µV/V + 24 µV from 20 Hz to 40 Hz

71 µV/V + 5.5 µV from 40 Hz to 20 kHz

120 µV/V + 16 µV from 20 kHz to 50 kHz

220 µV/V + 62 µV from 50 kHz to 100 kHz

390 µV/V + 120 µV from 100 kHz to 300 kHz

990 µV/V + 300 µV from 300 kHz to 500 kHz

2.1 mV/V + 730 µV from 500 kHz to 1 MHz

From 2.2 V to 22 V  

470 µV/V + 770µV from 10 Hz to 20 Hz

150 µV/V + 240 µV from 20 Hz to 40 Hz

71 µV/V + 53 µV from 40 Hz to 20 kHz

120 µV/V + 160 µV from 20 kHz to 50 kHz

220 µV/V + 310 µV from 50 kHz to 100 kHz

470 µV/V + 1.3 mV from 100 kHz to 300 kHz

1.1 mV/V + 3.9 mV from 300 kHz to 500 kHz

2.4 mV/V + 6.9 mV from 500 kHz to 1 MHz

From 22 V to 220 V 

470 µV/V + 7.8 uV/V from 10 Hz to 20 Hz

150 µV/V + 2.4 mV from 20 Hz to 40 Hz

72 µV/V + 830 µV from 40 Hz to 20 kHz

200 µV/V + 3.1 mV from 20 kHz to 50 kHz

470 µV/V + 7.7 mV from 50 kHz to 100 kHz

From 220 V to 1 kV 

77 µV/V + 2.7 mV from 50 Hz to 1 kHz

From 220 V to 330 V          

150 µV/V + 3.9 mV at 45 Hz

From 330 V to 1000 V        

240 µV/V + 7.5 mV at 45 Hz

D.C. current
47 µA/A + 7.7 nA from 10 μA to 220 μA

47 µA/A + 7.7 nA from 220 μA to 2.2 mA

47 µA/A + 77 nA from 2.2 mA to 22 mA

55 µA/A + 770 nA from 22 mA to 220 mA

77µA/A + 23 µA from 220 mA to 2.2 A

390 µA/A + 400 µA from 2.2 A to 11 A

800 µA/A + 370 µA from 11 A to 20 A

A.C. current

From 100 μA to 220 µA      

630 µA/A + 23 nA from 10 Hz to 20 Hz

330 µA/A + 19 nA from 20 Hz to 40 Hz

140 µA/A + 15 nA from 40 Hz to 1 kHz

570 µA/A + 36 nA from 1 kHz to 5 kHz

1.5 mA/A + 74 nA from 5 kHz to 10 kHz

From 220 µA to 2.2 mA       

620 µA/A + 39 nA from 10 Hz to 20 Hz

330 µA/A + 32 nA from 20 Hz to 40 Hz

130 µA/A + 31 nA from 40 Hz to 1 kHz

550 µA/A + 390 nA from 1 kHz to 5 kHz

1.4 mA/A + 770 nA from 5 kHz to 10 kHz

From 2.2 mA to 22 mA        

620 µA/A + 390 nA from 10 Hz to 20 Hz

330 µA/A + 310 nA from 20 Hz to 40 Hz

130 µA/A + 310 nA from 40 Hz to 1 kHz

550 µA/A + 3.9 µA from 1 kHz to 5 kHz

1.4 mA/A + 7.7 µA from 5 kHz to 10 kHz

From 22 mA to 220 mA       

620 µA/A + 4 µA from 10 Hz to 20 Hz

330 µA/A + 3.2 µA from 20 Hz to 40 Hz

150 µA/A + 3 µA from 40 Hz to 1 kHz

550 µA/A + 39 µA from 1 kHz to 5 kHz

1.4 mA/A + 77 µA from 5 kHz to 10 kHz

From 220 mA to 2.2 A        

590µA/A + 30µA from 40 Hz to 1 kHz

690µA/A + 72µA from 1 kHz to 5 kHz

7.9mA/A + 130µA from 5 kHz to 10 kHz

From 2.2 A  to 11 A 

520 µA/A + 1.5 mA from 45 Hz to 100 Hz

810 µA/A + 1.5 mA from 100 Hz to 1 kHz

24 mA/A + 1.6 mA from 1 kHz to 5 kHz

From 11 A to 20 A   

960 µA/A + 3.8 mA from 45 Hz to 100 Hz

1.2 mA/A + 3.8 mA from 100 Hz to 1 kHz

24 mA/A + 3.9 mA from 1 kHz to 5 kHz

Resistance

Within the ranges

33 µΩ/Ω + 780 µΩ 0 Ω to 11 Ω

24 µΩ/Ω + 1.2 mΩ from 11 Ω to 33 Ω

23 µΩ/Ω + 1.1 mΩ from 33 Ω to 110 Ω

24 µΩ/Ω + 1.4 mΩ from 110 Ω to 330 Ω

22 µΩ/Ω + 1.9 mΩ from 330 Ω to 1.1 kΩ

24 µΩ/Ω + 15 mΩ from 1.1 kΩ to 3.3 kΩ

23 µΩ/Ω + 19 mΩ from 3.3 kΩ to 11 kΩ

23 µΩ/Ω + 160 mΩ from 11 kΩ to 33 kΩ

23 µΩ/Ω + 160 mΩ from 33 kΩ to 110 kΩ

26 µΩ/Ω + 1.6 Ω from 110 kΩ to 330 kΩ

26 µΩ/Ω + 1.7 Ω from 330 kΩ to 1.1 MΩ

49 µΩ/Ω + 22 Ω from 1.1 MΩ to 3.3 MΩ

110 µΩ/Ω + 37 Ω from 3.3 MΩ to 11 MΩ

210 µΩ/Ω + 1.9 kΩ from 11 MΩ to 33 MΩ

400 µΩ/Ω + 2.6 kΩ from 33 MΩ t0 110 MΩ

2.4 mΩ/Ω + 73 kΩ from 110 MΩ to 330 MΩ

12 mΩ/Ω + 370 kΩ from 330 MΩ to 1090 MΩ

With fixed values

87 µΩ/Ω at 1 Ω

27 µΩ/Ω at 10 Ω

16 µΩ/Ω at 100 Ω

12 µΩ/Ω at 1 kΩ

11 µΩ/Ω at 10 kΩ

13 µΩ/Ω at 100 kΩ

18 µΩ/Ω at 1 MΩ

38 µΩ/Ω at 10 MΩ

108 µΩ/Ω at 100 MΩ




Dimensional metrology - Engineering equipment and precision instruments Bevel protractors Angle (arc) Comparison with a reference standard

Including compliance with AS B139

Capability

with Calibration and Measurement Capability of -
3.6 minutes of arc from 150 mm to 300 mm

Bore gauges Length measurements Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
2.5 μm from 2 mm to 50 mm

3.5 μm above 50 mm to 200 mm

Depth and height micrometers Length measurements Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

2 μm from 1 mm to 125 mm
(1.1+L/180) μm above 125 mm to 600 mm where L is the indicated depth in mm

Dial gauges Length measurements Comparison with a reference standard

Dial gauges and other displacement measuring devices


Capability

with Calibration and Measurement Capability of -

Dial Gauges
(0.8 + 0.032L) μm where L is the range in mm from 1 mm to 100 mm

Digital Indicators
(0.8 + 0.013L) μm where L is the range in mm from 1 mm to 100 mm
Dial Test Indicators

(0.8 + 100R) μm where R is the resolution in mm

Dial gauges; Thickness gauges Length measurements Comparison with a reference standard

Including compliance with AS 2103

Capability

with Calibration and Measurement Capability of -
(0.8 + 0.032L) μm from 1 mm to 100 mm where L is the range in mm

Eccentric mandrels Length measurements Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
0.21 μm from 1 to 10 μm eccentricity
0.43 μm from 10 to 30 μm eccentricity

External micrometers Length measurements Comparison with a reference standard

Including compliance with AS 2102

Capability

with Calibration and Measurement Capability of -
1.8 μm up to 25 mm
2.6 μm above 25 mm to 100 mm
(1.8+0.01L) μm where L is the length in mm
above 100 mm to 1200 mm

Feeler gauges Length measurements Comparison with a reference standard

Including compliance with 1655

Capability

with Calibration and Measurement Capability of -
(6L + 0.7) μm from 0.04 mm to 1 mm where L is thickness in mm

Internal micrometers Length measurements Comparison with a reference standard

Including compliance with AS 2101

Capability

with Calibration and Measurement Capability of -
2.5 μm from 25 mm to 150 mm
4 μm above 150 mm to 300 mm
(1.5 + 0.008L) μm above 300 mm to 900 mm
where L is the length in mm

Micrometer heads Length measurements Comparison with a reference standard

Including compliance with AS 2328

Capability

with Calibration and Measurement Capability of -
(0.4+0.6R) μm where R is the resolution in μm

Micrometer setting gauges Length measurements Comparison with a reference standard

Up to 1200 mm

Capability

with Calibration and Measurement Capability of -
(1 + 0.007L) μm up to 1200 mm where L is the length in mm

Precision spirit levels Angle (arc) Comparison with a reference standard

Including compliance with AS 2054

Capability

with Calibration and Measurement Capability of -
2 seconds of arc limited to  a sensitivity of 10 seconds of arc

Squares Length measurements Comparison with a reference standard

Including compliance with BS 939

Capability

with Calibration and Measurement Capability of -
2 μm from 100 mm to 200 mm

2.6 μm above 200 mm to 450 mm

4.3 μm above 450 mm to 600 mm

Steel rulers and measuring tapes Length measurements Comparison with a reference standard

Including compliance to AS 1290.4 (only to retractable steel pocket rules)

Capability

with Calibration and Measurement Capability of -
Steel rules
5.4 μm or (3.5+0.007L) μm (whichever is greater) up to 2 m where L is the length in mm
Retractable steel pocket rules
0.47 mm from 0.5 mm to 10 m

Straight edges Length measurements Comparison with a reference standard

Including compliance with AS 1003 and AS B72

Capability

with Calibration and Measurement Capability of -
2 μm from 50 mm to 300 mm

3 μm above 300 to 500 mm

5 μm above 500 to 1000 mm

8 μm above 1000 to 1500 mm

Surface plates Flatness Comparison with a reference standard

Including compliance with AS 1004

Excluding clause 3.4 rigidity

Capability

with Calibration and Measurement Capability of -
(3.6 L + 2) μm where L is length of longest side of the surface/table

Vernier calipers Length measurements Comparison with a reference standard

Including compliance with AS 1984, BS 887 and JIS 7507

Capability

with Calibration and Measurement Capability of -
(10 + 0.025L) μm up to 1.5 m for indication errors where L is the scale value in mm

Vernier height and depth gauges Length measurements Comparison with a reference standard

Including compliance with AS B138

Capability

with Calibration and Measurement Capability of -
Height gauges
 2.5 μm from 10 mm to 300 mm
 (6 + 0.006L) μm from 300 mm to 1000 mm where L is the indicated height in mm
 Depth gauges
 6 μm from 1 to 100 mm
 (5.5 + 0.006L) μm above 100 mm to 1000 mm where L is the indicated depth in mm

Dimensional metrology - Engineering equipment and precision instrumentsincluding on site calibrations Extensometers Length measurements Comparison with a reference standard

in laboratory and in situ

Including compliance to AS 1545

Capability

including on site calibrations

with Calibration and Measurement Capability of -
(0.89 + 0.79L) μm from 0.01 mm to 250 mm where L is the indicated extension in mm

Dimensional metrology - Jigs, fixtures, cutting tools, machine tools, gears, splines and serrations Components and QC standards; Crimp tools; Cutting tools; Jigs and fixtures Length measurements Comparison with a reference standard by differential measurement

Capability

with Calibration and Measurement Capability of -
(1 + 0.007 L) μm up to 1200 mm where L is the length in mm

Dimensional metrology - Length and angle standards Dial gauge calibrators; Extensometer calibrators Length measurements Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
(0.4+0.6R) μm where R is the resolution in μm

Precision graticules; Precision linear scales Length measurements; Microscope graticules Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
Precision graticules

1.5 μm with a minimum scale separation of 0.01 mm

Precision linear scales

2 μm up to 500 mm 

Dimensional metrology - Limit gauges and reference standards Indicator gauges; Radius gauges Radius Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
(8+1.1R) μm where R is the radius in mm

Plain plug gauges; Plain ring gauges Diameter Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
Plain plug gauges

1 μm from 2 mm to 50 mm
3 μm above 50 mm to 250 mm

Plain ring gauges

1 μm from 2 mm to 50 mm
3 μm above 50 mm to 250 mm

Force metrology - Force measuring and testing equipment Paper product testing equipment Force in compression; Force in tension Comparison measurement with reference load cell

Paper Burst (AS/NZS 1301.403s)
Densometer (AS 1301.420s)
Board Burst (AS/NZS 1301.438s)
Tensile/fracture toughness (AS 1301.448s)
Crush testing (AS/NZS 1301.449s)
STFI compression strength (AS 1301.450rp)
Box compression (AS 1301.800s)
 Huygen internal bond testers
 Taber stiffness (AS 1301.431rp)

Huygen internal bond testers
100 J/m2 to 350 J/m2
Taber stiffness
65 Taber units to 1000 Taber units

Capability

with Calibration and Measurement Capability of -
Huygen internal bond testers
1.4 J/m2 from 100 J/m2 to 350 J/m2
Taber stiffness
1.1% of range from 65 to 1000 Taber units

Force metrology - Force measuring and testing equipmentincluding on site calibrations Aircraft weighing kits; Hydraulic rams and jacks; Load cells; Load measuring rings Force in compression; Force in tension Comparison measurement with reference load cell

In tension up to 1000 kN and compression up to 500 kN to class AA including compliance to AS 2193
In tension up to 3.3 MN and in compression up to 20 MN to class A including compliance to  AS 2193

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN in compression

0.17% reading from 0.01 N to 1000 kN in tension

0.25% reading above 500 kN to 20 MN in compression

0.25% reading above 1000 kN to 3.3 MN in tension

Compression and universal machines in compression Force in compression Comparison measurement with reference load cell

Up to 500 kN to class AA and up to 20 MN to class A of the requirements of AS 2193 and including testing to ISO 7500-1 and ASTM E4
Verification of compression testing machines for concrete including self-alignment and restraint on tilt tests for compliance with BS 1881 Part 115

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN
0.25% reading above 500 kN to 20 MN

Elastic force measuring devices Force in compression; Force in tension Comparison measurement with reference load cell

Calibration of devices such as load measuring rings for soil testing machines,
electronic load cells and hydrostatic weighing units including those in
batching plants and aircraft weighing kits

including compliance to class AA including compliance to AS 2193

including compliance to class A including compliance to AS 2193

0.01 N to 20 MN  in compression

0.01 N to 3.3 MN.  in tension

in tension up to 1000 kN and compression up to 500 kN to class AA including compliance to AS 2193


in tension up to 3.3 MN and in compression up to 20 MN to class A including compliance to AS 2193

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN in compression

0.17% reading from 0.01 N to 1000 kN in tension

0.25% reading above 500 kN to 20 MN in compression

0.25% reading above 1000 kN to 3.3 MN in tension

Tension and universal machines in tension Force in tension Comparison measurement with reference load cell

Up to 500 kN to class AA and up to 3.3 MN to class A including compliance to AS 2193 and including testing to ISO 7500-1 and ASTM E4

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 1000 kN
0.25% reading above 1000 kN to 3.3 MN
 

Force metrology - Force standards Force calibrating equipment; Force standards and load cells used as force standards Force in compression; Force in tension Comparison measurement with reference load cell; Gravimetric measurement with reference mass

Including compliance with AS 2193; ISO 376


Capability

with Calibration and Measurement Capability of -
Force calibrating equipment; Force standards and load cells used as force standards used in tension
Calibration at forces up to 500 kN to Class 1 requirements of AS2193-Section 4
with calibration and measurement uncertainty of 0.03% of reading from 0.01N to 500 kN
Force calibrating equipment; Force standards and load cells used as force standards used in compression
Calibration at forces up to 2000 kN to Class 2 requirements of AS 2193 Section 4
with calibration and measurement uncertainty of 0.03% of reading up to 500 kN
with calibration and measurement uncertainty of 0.05% of reading from 500kN to 2000 kN
Force in compression; Force in tension Comparison measurement with reference load cell

Including determination of class 0 requirements of AS 2193 and compliance with ISO 379 and ASTM E74

9.8 N to 10 kN

Capability

with Calibration and Measurement Capability of -
0.03% of reading or 0.14 N (whichever is greater)

Force metrology - Hardness standards and equipment Hardness standards Brinell hardness; Rockwell hardness; Vickers hardness Comparison with a reference standard

Hardness of metal products

Brinell hardness tests
Rockwell hardness tests
Vickers hardness tests 

Hardness of metal products

Brinell hardness tests in the range 9.8 to 29.4 kN


Rockwell hardness tests using A, B, C, E, F, G, H, K, N, T scales


Vickers hardness tests in the range 9.8 to 980 N

Penetrometers and penetration cones Penetration resistance Direct length measurement AS 1289.6.3.2
Rubber bases Rubber hardness Comparison with a reference standard

25 IRHD to 97 IRHD

Capability

with Calibration and Measurement Capability of -
0.7 IRHD

Rubber hardness Comparison with a reference standard

Capability

Rubber hardness tests (IRHD) on rubber products including liquid limit device bases
Timing tests on asphalt testing machines calibration to
AS 1289.6.8.1, AS 2891.12.1 and AS 2891.13.1
Calibration of frequency of vibrating tables to AS 1289.5.5.1 and AS 2350.12
Force metrology - Hardness standards and equipmentincluding on site calibrations Brinell hardness machines; Portable Brinell measuring microscopes Brinell hardness Comparison with a reference standard
Charpy impact machines Charpy impact Comparison with a reference standard; Direct force and length measurement

0.5 J to 600 J

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.2% reading from 0.5 J to 600 J

Dead weight micro-hardness rubber testers; Dead weight rubber hardness testers; Rubber hardness meters (durometers) Rubber hardness Comparison with a reference standard

From 10 IRHD to 99.5 IRHD

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
1% of reading in IRHD from 10 IRHD to 99.5 IRHD

Indenters; Rockwell hardness machines; Rockwell superficial hardness machines Rockwell hardness Comparison with a reference standard
Indenters; Vickers hardness machines; Vickers low-load hardness machines; Vickers micro-hardness machines Vickers hardness Comparison with a reference standard
Izod impact machines Izod impact Comparison with a reference standard; Direct force and length measurement

2 J to 170 J

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.2% reading from 2 J to 170 J

Mass - Determination of mass and calibration of weighing devices Mass standards Mass Gravimetric measurement against reference mass

From 10 mg to 30 kg

Capability

with Calibration and Measurement Capability of -
0.03 mg from 10 mg to 5 g

0.04 mg above 5 g to 10 g

0.05 mg above 10 g to 20 g

0.06 mg above 20 g to 50 g

0.15 mg above 50 g to 100 g

0.20 mg above 100 g to 200 g

3.5 mg above 200 g to 1 kg

4 mg above 1 kg to 2 kg

10 mg above 2 kg to 5 kg

25 mg above 5 kg to 10 kg

50 mg above 10 kg to 20 kg

130 mg above 20 kg to 30 kg

Mass - Determination of mass and calibration of weighing devicesincluding on site calibrations Industrial weighing devices; Laboratory weighing devices; Precision laboratory balances Mass Gravimetric measurement against reference mass

Capability

with Calibration and Measurement Capability of -

Including on site calibrations

in the range from 0.01 g and up to 1000 kg
2 in 10⁶ or 20 μg (whichever is greater) ) in the range from 0.01g and up to 250 g
3 in 106 in the range from 250 g and up to 500 g
3 mg in the range from 500 g and up to 1.1 kg
2 in 106 or 4 mg (whichever is greater) in the range from 1.1 kg and up to 21 kg
4 in 106 in the range from 21 kg and up to 31 kg
5 in 106 in the range from 31 kg and up to 41 kg
 5 in 105 in the range from 41 kg and up to 1000 kg

Pressure metrology - Pressure and vacuum measuring equipmentincluding on site calibrations Pressure control devices; Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges Gauge pressure Comparison with dead weight tester; Comparison with reference instrument

Including test gauges as defined in AS 1349

-100 kPa to 120 MPa

Capability

with Calibration and Measurement Capability of -
0.05% of reading or 0.05 kPa (whichever is greater) from 100 kPa to 120 MPa
0.23% of reading from - 100 kPa to - 20 kPa and 20 kPa to 100 kPa
0.46% of reading or 80 Pa (whichever is greater) from - 20 kPa to 20 kPa


For on site calibrations
with Calibration and Measurement Capability of -
0.23% of reading from -100 kPa to - 20 kPa and 20 kPa to 120 MPa
0.46% of reading or 80 Pa (whichever is greater) from - 20 kPa to 20 kPa
Temperature metrology - Ancillary temperature measuring equipment Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators Resistance to temperature conversion; Volt to temperature conversion Direct measurement by electrical input

Capability

with Calibration and Measurement Capability of -
0.3 °C from -200 °C to 1370 °C by electrical simulation (ACJC off)
0.7 °C from -200 °C to 1370 °C by electrical simulation (ACJC on)

Temperature metrology - Humidity measuring equipment Hygrometers; Relative humidity sensors Relative humidity (RH) Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
1.7% RH from 10°C to 19°C and above 23°C to 60°C from 10 % RH to 90 % RH
 1.5% RH above 19°C to 23°C from 10 % RH to 90 % RH 

Temperature metrology - Non-contact temperature measuring equipment Radiation pyrometers Temperature Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
1.6 °C + 0.8% of T (where T is Temperature in °C ) when designed for 0.95 emissivity for IR 7-14 μm spectral response for pyrometers from 0 °C to 450 °C

Temperature metrology - Temperature measuring equipment Base metal thermocouples Temperature Measurement against reference standard

Capability

with Calibration and Measurement Capability of -
0.5 °C + 0.1%T from -80 °C to 0 °C
0.5 °C above 0 °C to 420 °C

Bimetallic systems Temperature Measurement against reference standard

Capability

with Calibration and Measurement Capability of -
0.5 °C from 0 °C to 250 °C

Liquid in glass (LIG) thermometers Temperature Measurement against reference standard

Capability

with Calibration and Measurement Capability of -
1/5 of one scale division or 0.05 °C (whichever is the larger) at ice point
0.24 °C from -30 °C to 100 °C
0.3 °C above 100 °C to 200 °C

(partial immersion thermometers only across the measurement range)
Surface probes Temperature Measurement against reference standard

Capability

with Calibration and Measurement Capability of -
0.5 °C + 0.4%T from 25 °C to 350 °C

Temperature metrology - Temperature measuring equipmentincluding on site calibrations Digital temperature measuring systems; Temperature loggers - Single and multi-channel Temperature Measurement against reference standard

Capability

Including on site calibrations

with Calibration and Measurement Capability of -
0.2 °C from -80 °C to 200 °C
0.5 °C above 200 °C to 420 °C
2 °C above 420 °C to 1000 °C
0.5 °C from 5 °C to 80 °C for thermohygrometers

Temperature metrology - Verification of controlled enclosures Environmental chambers - Humidity Humidity By temperature and humidity measurement

Capability

Including on site calibrations

with Calibration and Measurement Capability of -

1.7% RH from 10 ºC to 60 ºC and in the range 10% to 90% RH

Temperature metrology - Verification of controlled enclosuresincluding on site calibrations Autoclaves and sterilising ovens; Environmental chambers - Temperature; Freezers; Furnaces; Incubators; Ovens Spatial uniformity; Temperature Direct temperature measurement

Capability

Including on site calibrations
with Calibration and Measurement Capability of -
Ovens and Furnaces
1.0 °C from 0 °C to 420 °C
2 °C above 420 °C to 1100 °C
Incubators
0.5 °C from ambient to 100 °C
Fridges
1.0 °C from 0 °C to 20 °C
Autoclaves and sterilising ovens
1.0 °C from ambient to 200 °C
Industrial freezers
1.0 °C from -80 °C to 0 °C
Environmental Chambers (Temperature)
 0.6 º C from -80 °C to 200 ºC

Efficiency of drying ovens including compliance to AS 1289.0 clause 4.2.3
Rate of loading of drying ovens including compliance to AS 1289.0 clause 4.2.4 with Calibration and Measurement Capability of 0.5 g/h

Torque - Torque measuring and testing equipmentincluding on site calibrations Torque transducers Torque Gravimetric measurement with reference beam

Capability

with Calibration and Measurement Capability of -

in the range from 0.1 Nm and up to 1500 Nm
0.04% of reading in the range from 0.1 Nm and up to 100 Nm
0.1% of reading in the range above 100 Nm and up to 1500 Nm

Torque wrenches Torque Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

Including onsite calibrations

0.5% of reading In the range from 0.1 Nm and up to 1500 Nm


The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.