Centigrade Commissioning Pty Ltd

Site

Centigrade Commissioning Testing Facility

Accreditation No.

19992

Site No.

23460

Date of Accreditation

22 Jun 2017

Address

Unit 5, 7 Macadam Place
Balcatta, WA 6021
Australia

centigrade.com.au

Contact

Mr Phil Duffy P: +61 (08) 92401992

Availability

Services available to external clients

Scope of Accreditation

Centigrade Commissioning Testing Facility

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Air conditioning and ventilation systems Air pressure Not applicable AS 1807.10 (2000) Mechanically ventilated health care enclosures,
for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9)
Exhaust airflow rate Not applicable AS 1807.1 (2000) Mechanically ventilated health care enclosures,
for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9)
Integrity of HEPA filter installations Not applicable AS 1807.6 (2000),
AS 1807.7 (2000)
Mechanically ventilated health care enclosures,
for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9)
Biological safety cabinets Illuminance Not applicable AS 1807 clause 4.5
for compliance with:
AS 2252.1,
AS 2252.2
Air velocity and uniformity of air velocity Not applicable

AS 1807 clause 4.1

for compliance with:
AS 2252.2
Air barrier containment Cold DOP AS 1807 clause 4.9 for compliance with:
AS 2252.2 
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4
for compliance with:
AS 2252.1,
AS 2252.2
Work zone integrity Cold DOP AS 1807 clause 4.3 for compliance with:
AS 2252.2
Inward air velocity Not applicable AS 1807 clause 4.8
for compliance with:
AS 2252.1,
AS 2252.2
Ultraviolet intensity Not applicable AS 1807 clause 4.10 for compliance with:
AS 2252.1,
AS 2252.2
Sound level Not applicable AS 1807 clause 4.7
for compliance with:
AS 2252.1,
AS 2252.2
Clean rooms Sound level Not applicable AS 1807.16 (2000)
Integrity of HEPA filter installations Cold DOP AS ISO 14644.3 section 7, clauses B.7.2 & B.7.4,
AS 1807.6 (2000),
AS 1807.7 (2000)
Air velocity and uniformity of air velocity Not applicable AS ISO 14644.3 Section 2, clauses B.2.2.2, B.2.2.5 and B.2.3.4,
AS 1807.1 (2000)
Air pressure Not applicable AS ISO 14644.3 section 1, clause B.1.2,
AS 1807.10 (2000)
Illuminance Not applicable AS 1807.15 (2000)
Air flow direction and visualization Not applicable AS ISO 14644.3 section 3, clause B.3.3.4
Leakage Cold DOP AS ISO 14644.3 section 8, clause B.8.2.2
Particle count in work zone Automatic particle counter AS ISO 14644.1 Annex A, section 5, clause A.5
Clean workstations Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4,
AS 1807.6 (2000),
AS 1807.7 (2000)
for compliance with:
AS 2252.6
Particle count in work zone Automatic particle counter AS ISO 14644.1 Annex A section 5, clause A.5 for compliance with:
AS 2252.6
Illuminance Not applicable AS 1807 clause 4.5,
AS 1807.15 (2000)
for compliance with:
AS 2252.6
Air velocity and uniformity of air velocity Not applicable AS 1807 clause 4.1,
AS 1807.1 (2000)
for compliance with:
AS 2252.6
Sound level Not applicable AS 1807 clause 4.7,
AS 1807.20 (2000)
for compliance with:
AS 2252.6
Work zone integrity Cold DOP

AS 1807 clause 4.3

for compliance with:
AS 2252.6
Ultraviolet intensity Not applicable AS 1807 clause 4.10 for compliance with:
AS 2252.6
Cytotoxic drug safety cabinets Work zone integrity Cold DOP AS 1807 clause 4.3 for compliance with:
AS 2252.5
Ultraviolet intensity Not applicable AS 1807 clause 4.10 for compliance with:
AS 2252.5
Air velocity and uniformity of air velocity Not applicable AS 1807 clause 4.1 for compliance with:
AS 2252.5
Sound level Not applicable AS 1807 clause 4.7 for compliance with:
AS 2252.5
Particle count in work zone Automatic particle counter AS ISO 14644.1 Annex A, section 5 clause A.5 for compliance with:
AS 2252.5
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 for compliance with:
AS 2252.5
Air barrier containment Cold DOP AS 1807 clause 4.9 for compliance with:
AS 2252.5
Illuminance Not applicable AS 1807 clause 4.5 for compliance with:
AS 2252.5
Fume cupboards and recirculating fume cabinets Illuminance Not applicable AS 1807.15 (2000) For compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Extraction performance Smoke visualisation AS/NZS 2243.8 Appendix A,
AS/NZS 2243.9 Appendix A
for  compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Extraction performance Face velocity

AS/NZS 2243.8 Appendix B,

AS/NZS 2243.9 Appendix B
for  compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Sound level Not applicable AS 1807.20 (2000) For compliance with:
AS/NZS 2243.8,
AS/NZS 2243.9
Pharmaceutical isolators Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4,
AS 1807.6 (2000)
AS 1807.7 (2000)
for compliance with:
AS 4237
Air velocity and uniformity of air velocity Not applicable AS 1807 clause 4.1,
AS 1807.1 (2000)
for compliance with:
AS 4237
Air pressure Not applicable AS ISO 14644.1 section1, clause B.1.2,
AS 1807.10 (2000)
for compliance with:
AS 4237
Particle count in work zone Automatic particle counter AS ISO 14644.1 Annex A, section 5, clause A.5 for compliance with:
AS 4273

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.