National Association of Testing Authorities, Australia
Scope of Accreditation
Centigrade Commissioning Pty Ltd
Site
Centigrade Commissioning Testing Facility
Accreditation No.
19992
Site No.
23460
Date of Accreditation
22 Jun 2017
Contact
Mr Phil Duffy P: +61 (08) 92401992
Availability
Services available to external clients
Scope of Accreditation
Centigrade Commissioning Testing Facility
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of air control equipment | Air conditioning and ventilation systems | Air pressure | Not applicable | AS 1807.10 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) |
Exhaust airflow rate | Not applicable | AS 1807.1 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) | ||
Integrity of HEPA filter installations | Not applicable | AS 1807.6 (2000), AS 1807.7 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) | ||
Biological safety cabinets | Illuminance | Not applicable | AS 1807 clause 4.5 | for compliance with: AS 2252.1, AS 2252.2 | |
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1 | for compliance with: AS 2252.2 | ||
Air barrier containment | Cold DOP | AS 1807 clause 4.9 | for compliance with: AS 2252.2 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4 | for compliance with: AS 2252.1, AS 2252.2 | ||
Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.2 | ||
Inward air velocity | Not applicable | AS 1807 clause 4.8 | for compliance with: AS 2252.1, AS 2252.2 | ||
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.1, AS 2252.2 | ||
Sound level | Not applicable | AS 1807 clause 4.7 | for compliance with: AS 2252.1, AS 2252.2 | ||
Clean rooms | Sound level | Not applicable | AS 1807.16 (2000) | ||
Integrity of HEPA filter installations | Cold DOP | AS ISO 14644.3 section 7, clauses B.7.2 & B.7.4, AS 1807.6 (2000), AS 1807.7 (2000) | |||
Air velocity and uniformity of air velocity | Not applicable | AS ISO 14644.3 Section 2, clauses B.2.2.2, B.2.2.5 and B.2.3.4, AS 1807.1 (2000) | |||
Air pressure | Not applicable | AS ISO 14644.3 section 1, clause B.1.2, AS 1807.10 (2000) | |||
Illuminance | Not applicable | AS 1807.15 (2000) | |||
Air flow direction and visualization | Not applicable | AS ISO 14644.3 section 3, clause B.3.3.4 | |||
Leakage | Cold DOP | AS ISO 14644.3 section 8, clause B.8.2.2 | |||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5, clause A.5 | |||
Clean workstations | Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4, AS 1807.6 (2000), AS 1807.7 (2000) | for compliance with: AS 2252.6 | |
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A section 5, clause A.5 | for compliance with: AS 2252.6 | ||
Illuminance | Not applicable | AS 1807 clause 4.5, AS 1807.15 (2000) | for compliance with: AS 2252.6 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1, AS 1807.1 (2000) | for compliance with: AS 2252.6 | ||
Sound level | Not applicable | AS 1807 clause 4.7, AS 1807.20 (2000) | for compliance with: AS 2252.6 | ||
Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.6 | ||
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.6 | ||
Cytotoxic drug safety cabinets | Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.5 | |
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.5 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1 | for compliance with: AS 2252.5 | ||
Sound level | Not applicable | AS 1807 clause 4.7 | for compliance with: AS 2252.5 | ||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5 clause A.5 | for compliance with: AS 2252.5 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4 | for compliance with: AS 2252.5 | ||
Air barrier containment | Cold DOP | AS 1807 clause 4.9 | for compliance with: AS 2252.5 | ||
Illuminance | Not applicable | AS 1807 clause 4.5 | for compliance with: AS 2252.5 | ||
Fume cupboards and recirculating fume cabinets | Illuminance | Not applicable | AS 1807.15 (2000) | For compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | |
Extraction performance | Smoke visualisation | AS/NZS 2243.8 Appendix A, AS/NZS 2243.9 Appendix A | for compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Extraction performance | Face velocity | AS/NZS 2243.8 Appendix B, AS/NZS 2243.9 Appendix B | for compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Sound level | Not applicable | AS 1807.20 (2000) | For compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Pharmaceutical isolators | Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4, AS 1807.6 (2000) AS 1807.7 (2000) | for compliance with: AS 4237 | |
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1, AS 1807.1 (2000) | for compliance with: AS 4237 | ||
Air pressure | Not applicable | AS ISO 14644.1 section1, clause B.1.2, AS 1807.10 (2000) | for compliance with: AS 4237 | ||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5, clause A.5 | for compliance with: AS 4273 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
19992
Site No.
23460
Print date
27 Nov 2024
END OF SCOPE