National Association of Testing Authorities, Australia
Scope of Accreditation
Sick Pty Limited
Site
Chemical Laboratory
Accreditation No.
2246
Site No.
2239
Date of Accreditation
23 Oct 1987
Contact
Mr Rod Meredith P: +61 (02) 98462201
Availability
Services conditionally available to external clients
Scope of Accreditation
Chemical Laboratory
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Gas analysers | Gas analysers; Mine safety and confined space equipment | Concentration | Direct measurement by certified reference material | in-house method WOS0001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration in the laboratory or at a customer site (above ground)With Calibration and Measurement Capability of- Carbon monoxide - CO (Infra-red): 2.3% of reading over the range 20-5000 part per 106 (ppm) Carbon monoxide - CO (Electrochemical): 2.3% of reading over the range 1-1000 part per 106 (ppm) Carbon dioxide - CO2 (Infra-red): 2.3% of reading over the range 0.001-100 %vol/vol Methane - CH4 (Infra-red): 2.3% of reading over the range 0.01-100 %vol/vol Nitric oxide - NO (Infra-red): 2.3% of reading over the range 0.0075-100 %vol/vol Oxygen - O2 (Paramagnetic): 2.3% of reading over the range 0.01-100 %vol/vol Oxygen - O2 (Electrochemical): 2.3% of reading over the range 0.01-25 %vol/vol Sulfur dioxide - SO2 (Infra-red): 2.3% of reading over the range 0.004-100 %vol/vol Propane - C3H8 (infra-red): 2.3% of reading over the range 0.01-100 %vol/vol |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
2246
Site No.
2239
Print date
27 Nov 2024
END OF SCOPE