National Association of Testing Authorities, Australia
Scope of Accreditation
National Measurement Institute (NMI)
Site
Force Standards Project
Accreditation No.
1
Site No.
25589
Date of Accreditation
01 Jul 2023
Contact
Availability
Services conditionally available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Force metrology - Force measuring and testing equipment | Elastic force measuring devices; Force gauges; Load cells | Force in compression; Force in tension | Comparison measurement with reference load cell; Gravimetric measurement with reference mass | AS 2193 ASTM E74 ISO 376 and In house procedure POM-FORCE-TM1 | For 50N to 550kN: Comparison measurement with deadweight in compression and tension. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of - 2 in 105 in the range 50 N to 550 kN (tension and compression); | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Force standards | Force standards and load cells used as force standards | Force in compression; Force in tension | Comparison measurement with reference load cell; Gravimetric measurement with reference mass | AS 2193 ASTM E74 ISO 376 and In house procedure POM-FORCE-TM1 | For 50 N to 550 kN: Comparison measurement with deadweight in compression and tension. For 0.5 MN to 4.5 MN: Comparison measurement with reference load | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -2 in 105 in the range 50 N to 550 kN (tension and compression); 2 in 104 in the range 0.5 to 1.5 MN (compression); 4 in 104 in the range 1.5 to 4.5 MN (compression); |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
1
Site No.
25589
Print date
22 Dec 2024