Fulton Hogan Industries Pty Ltd

Site

Geebung Laboratory

Accreditation No.

2887

Site No.

5314

Date of Accreditation

22 Feb 1994

Address

395 Bilsen Road
Geebung, QLD 4034
Australia

fultonhogan.com

Contact

Mr Daniel Worso-Mansfield P: +61 (07) 33633815

Availability

Services conditionally available to external clients

Scope of Accreditation

Geebung Laboratory

ISO/IEC 17025 (2017)

Materials

Service Product Determinant Technique Procedure Limitations
Analysis of bituminous materials - Composition Bituminous materials Residue on evaporation Not applicable

AS/NZS 2341.23

Non-aqueous volatiles Calculation by difference

AS/NZS 2341.24

Water content Dean and Stark

AS 2341.9

Analysis of bituminous materials - Properties Bituminous materials Sedimentation Not applicable AS/NZS 2341.27
pH of bituminous emulsions Classical

AS/NZS 2341.32

Sample handling and conditioning Not applicable

AS/NZS 2341.21, Austroads ATM 102

Softening point Ring and ball

AS 2341.18; Austroads Method AGPT/T131

Sieve residue Sieve analysis

AS/NZS 2341.26

Breaking behaviour Setting time AS 2341.29
Viscosity Brookfield viscometer

Austroads ATM 111

Consistency of bitumen emulsion Derived Engler calculation AS 2341.25;  In-house method FHMS-04
Particle charge Not applicable AS 2341.22
Torsional recovery Not applicable

Austroads ATM T122

Viscosity Rotational AS 2341.4
Segregation of bituminous materials Not applicable Austroads Method AGPT/T108
Penetration of bitumen Penetration index MR (Qld) Method Q386
Penetration of bitumen Not applicable AS 2341.12
Sample collection Bituminous materials Not applicable Polymer modified bitumens from tanks, tankers and drums Austroads ATM T101
Not applicable Cutback bitumens from tanks, tankers and drums AS 2157 Appendix B
Not applicable Bitumen emulsions from tanks, tankers and drums; Polymer modified bitumens from tanks, tankers and drums

AS 1160 Appendix A

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.