Metering & Measurement - NSW Pty Ltd

Site

Gosford (Mobile Prover)

Accreditation No.

13047

Site No.

13040

Date of Accreditation

27 Aug 1997

Address

44 Chivers Road
Somersby, NSW 2250
Australia

Contact

Mr Paul Miller P: +61 0418436989

Availability

Services available to external clients

Scope of Accreditation

Gosford (Mobile Prover)

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Flow metrology - Flow measuring devices and systems Liquid meters Flow rate Comparison with a reference meter; Volumetric transfer

  AS 4250.1 and AS 4250.5

Capability

including on-site calibration

Calibration of flow meters using liquid hydrocarbons (other than LPG) and water;
with Calibration and Measurement Capability of-


In the range of 10 L/min to 6000 L/min using volumetric tank prover of 200 L to 6000 L
0.05% of tank prover volume


In the range of 10 L/min to 3000 L/min using piston prover
0.03% of volume equal to 5 passes of a 34 L piston prover


In the range of 10 L/min to 2760 L/min using a master meter
0.05% of volume for a minimum dispense time of 1 minute

Volume and density - Industrial volumetric equipment and bulk storage Pipeprovers Volume Comparison with a reference meter

based on the methods of AS 4250.2 and AS 4250.5

Capability

including on-site calibration

Calibration of mechanical displacement meter provers using liquid hydrocarbons (other than LPG) and water
by transfer meter referred to a compact prover
In the range of 365 L to 23 350 L
with Calibration and Measurement Capability of -
0.03% of prover based volume

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.