 Hinco Instruments
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature metrology - Ancillary temperature measuring equipment | Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators | Resistance to temperature conversion; Volt to temperature conversion | Direct measurement by electrical input | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Capabilitywith Calibration and Measurement Capability of Measure and source 0.25 % of range or 3.5 ºC (whichever is greater) from -200 ˚C to 1372 ˚C (Type K thermocouple) 0.25 % of range or 2.0 ºC (whichever is greater) from -200 ˚C to 1200 ˚C (Type J thermocouple) 0.25 % of range or 3.5 ºC (whichever is greater) from -100 ˚C to1300 ˚C (Type N thermocouple) 0.25 % of range or 4.0 ºC (whichever is greater) from 0 ˚C to 1767 ˚C (Type R thermocouple) 0.25 % of range or 1.3 ºC (whichever is greater) from -200 ˚C to 400˚C (Type T thermocouple) 0.25 % of range or 2.3 ºC (whichever is greater) from -200 ˚C to 800 ˚C (RTD PT100 ) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature metrology - Temperature measuring equipment | Digital temperature measuring systems; Temperature loggers - Single and multi-channel | Temperature | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Capabilityincluding on site calibrations with Calibration and Measurement Capability of 0.25 °C from -25 ˚C to 0 ˚C 0.05˚C at 0 ˚C (Using Ice Point) 0.1 ˚C above 0 ˚C to 200 ˚C 1.0 ˚C above 200 ˚C to 800 ˚C 3.25˚C above 800 ˚C to 1000˚C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature metrology - Temperature standards and reference equipment | Dry block calibrators | Temperature | Direct measurement using a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| CapabilityIncluding on-site calibrations with Calibration and Measurement Capability of 0.25˚C from -25 ˚C to 0 ˚C 0.2 ˚C above 0 ˚C to 200 ˚C 1.0 ˚C above 200 ˚C to 800 ˚C 3.25 ˚C above 800 ˚C to 1000 ºC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||