
National Association of Testing Authorities, Australia
Scope of Accreditation
Hinco Instruments
Site
Hinco Instruments
Accreditation No.
21447
Site No.
25808
Date of Accreditation
14 Aug 2025
Contact
Mr Hayden Wetton P: +61 (08) 94556777
Availability
Services available to external clients
Scope of Accreditation
Hinco Instruments
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature metrology - Ancillary temperature measuring equipment | Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators | Resistance to temperature conversion; Volt to temperature conversion | Direct measurement by electrical input | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability ofMeasure and source 0.25 % of range or 3.5 ºC (whichever is greater) from -200 ˚C to 1372 ˚C (Type K thermocouple) 0.25 % of range or 2.0 ºC (whichever is greater) from -200 ˚C to 1200 ˚C (Type J thermocouple) 0.25 % of range or 3.5 ºC (whichever is greater) from -100 ˚C to1300 ˚C (Type N thermocouple) 0.25 % of range or 4.0 ºC (whichever is greater) from 0 ˚C to 1767 ˚C (Type R thermocouple) 0.25 % of range or 1.3 ºC (whichever is greater) from -200 ˚C to 400˚C (Type T thermocouple) 0.25 % of range or 2.3 ºC (whichever is greater) from -200 ˚C to 800 ˚C (RTD PT100 ) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Digital temperature measuring systems; Temperature loggers - Single and multi-channel | Temperature | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on site calibrationswith Calibration and Measurement Capability of 0.25˚C from -25 ˚C to 150˚C 2.0 ˚C above 150 ˚C to 500˚C 3,2˚C above 500 ˚C to 1000˚C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature standards and reference equipment | Dry block calibrators | Temperature | Direct measurement using a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of 0.5 ºC from -25 ˚C to 150 ˚C 4.0 ºC above 150 ˚C to 300 ˚C 6.0 ºC above 300 ˚C to 500 ºC 8.5 ºC above 500 ˚C to 750 ºC 11 ºC above 750 ˚C to 1000 ºC |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21447
Site No.
25808
Print date
24 Aug 2025
END OF SCOPE