Attested Pressure Services

Site

Hydrostatic/Pneumatic Pressure Testing

Accreditation No.

15492

Site No.

16424

Date of Accreditation

09 Oct 2006

Address

8 Thorpe Way
Kwinana Beach, WA 6167
Australia

attested.com.au

Contact

Mr Shaun McLean P: +61 (08) 94193300

Availability

Services available to external clients

Scope of Accreditation

Hydrostatic/Pneumatic Pressure Testing

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations

Suspended

Evaluation of mechanical performance of high pressure oil and gas pipelines
High pressure oil and gas pipelines Strength, leak and combined pressure evaluation Not applicable AS 2885.5, AS/NZS 4645.2 section 6, AS/NZS 4645.3 section 6,  AS/NZS 5601.1 Appendix E, API RP 1110, ASME B31.8 section 841.3,  DNVGL-ST-F101 up to 120 MPa
Evaluation of mechanical performance of low pressure oil and gas pipelines Low pressure oil and gas pipelines Strength, leak and combined pressure evaluation Not applicable APGA Code of Practice,
AS/NZS 2033 section 7,
AS/NZS 2566.2 section 6 Appendix M4, M5, M6, M8,
AS 2885.5, AS/NZS 4645.2 section 6,
AS/NZS 4645.3 section 6,
AS/NZS 5601.1 Appendix E,
DNGL-ST-F101 section 10J.
up to 70 MPa
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Hydrostatic pressure Not applicable AS 1180.5 (1999) sections 7.1, 7.3 and 7.4, AS 2117 sections 2.1 and 2.2, AS 4233.1 Appendix E, ISO1402 sections 8.1, 8.3 and 8.4 up to 160 MPa including on-site testing
Piping; Pressure fittings Hydrostatic pressure Not applicable API 16C section 7.5, API 7K section 8.7, AS 2419.1 sections 12.2 and 12.3, AS 2419.2 section 4,  AS 3500.1 section 18.3, AS 4037 section 17, AS 4041 section 6.7, AS 4795.2 sections 5.2.1, 5.2.2, 5.2.3, 5.2.6, 5.3.2, 5.3.3, 5.3.4, 5.3.5 and 5.3.6, ASME B31.1 section 137.4, ASME B31.3 section 345.4, ASME B31.8 sections 841.3, 842.4, 843.4, ASME B31.12 section IP-10.6, AS/NZS 1462.8 section 7, AS/NZS 2033 section 7, AS 2885.5, AS/NZS 3788 Appendix D sections 15, 17 and 18,  AS/NZS 4058 sections 4.4 and 4.5, DNVGL-OS-E101 Chapter 2, DNVGL-ST-F101 section 8G, up to 160 MPa including on-site testing
Pneumatic pressure Not applicable AS 4037 section 18, AS 4041 section 6.8, ASME B31.1 section 137.5, ASME B31.3 section 345.5, ASME B31.12 section IP-10.7, AS/NZS 3788 Appendix D16 up to 120 MPa including on-site testing
Pressure vessels Pneumatic pressure Not applicable API 620 section 7.18.3, AS 1210 sections 5.11 and 5.14 , AS 1692 section 2.8.3, AS 4037 section 18, API 650 sections 7.3.5 and 7.3.8, AS/NZS 3788 Appendix D16. up to 120 MPa including on-site testing.
Hydrostatic pressure Not applicable API 620 section 7.18.4, API 650 sections 7.3.6 and 7.3.7, AS 1210 section 5.10, AS 1692 section 2.8.2, AS 4037 section 17,  AS/NZS 1200 Appendix J,  AS/NZS 3788 Appendices D15 and D17. up to 120 MPa including on-site testing
Valves Hydrostatic pressure Not applicable API 526 section 9, API 527 section 4, API 598, API 6D section 9, AS 1271 section 3.7 up to 160 MPa including on-site testing
Pneumatic pressure Not applicable API 526 section 9, API 527 sections 2 and 5, API 598, API 6D Annex H up to 120 MPa including on-site testing
Evaluation of mechanical performance of water and sewer pipelines Sewer pipelines Strength, leak and combined pressure evaluation Not applicable AS/NZS 2033 section 7,
AS/NZS 2566.2 section 6 Appendix N2, N3, N4
up to 70 MPa
Water pipelines Strength, leak and combined pressure evaluation Not applicable AS/NZS 2033 section 7,
AS/NZS 2566.2 section 6 Appendix M4, M5, M6, M8,
ASME B31.4 section 437
up to 70 MPa

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.