National Association of Testing Authorities, Australia
Scope of Accreditation
LAF Technologies Pty Ltd
Site
LAF Technologies Pty Ltd
Accreditation No.
14775
Site No.
22298
Date of Accreditation
25 Nov 2014
Contact
Mr Brad Green P: +61 1300306002
Availability
Services available to external clients
Scope of Accreditation
LAF Technologies Pty Ltd
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow metrology - Environmental flow measuring devices and systems | Microbial air samplers | Flow rate | Comparison with a reference meter | in-house method SOP Air Sampler Rev 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -3.5 L/min at 100 L/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Optical metrology - Particle measuring devices | Aerosol photometers | Flow rate; Linearity | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -Calibration of aerosol photometers with oil particulates at flow rates 28 L/min Measurement of the linearity of the flow rates of aerosol photometers 2% at 100% scale reading 3% at 80% scale reading 4% at 60% scale reading 6% at 40% scale reading 12% at 20% scale reading Measurement of flow rate 0.57 L/min at 28 L/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Particle counters - Air | Flow rate; Particle count; Particle size | Comparison with a reference standard | Calibration of airborne particle counters including the requirements of ISO 21501-4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -Calibration of airborne particle counters Maximum uncertainty of 2.4% of particle size in the range from 0.2 μm to 30 μm at flow rates from 1 L/min to 100 L/min |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14775
Site No.
22298
Print date
27 Dec 2024
END OF SCOPE