Bullivants Pty Limited

Site

Mackay Laboratory

Accreditation No.

369

Site No.

9784

Date of Accreditation

24 Nov 1994

Address

43 - 51 Diesel Drive
Paget, QLD 4740
Australia

bullivants.com

Contact

Ms Melissa Palmer P: +61 0429728101

Availability

Services available to external clients

Scope of Accreditation

Mackay Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of load generating lifting appliances Serial and lever hoists Operational load Not applicable

AS 1418.2

1 to 1500 kN, including on-site and mobile rig testing

Evaluation of load handling, rigging and tensioning systems C-hooks; Eye bolts; Eye hooks; Fittings; Lifting rings and links; Rigging screws and turnbuckles; Shackles; Shank hooks; Sheave blocks; Sockets; Swivels Breaking load; Proof load Not applicable

AS 2317.1, AS 2318, AS 2319, AS 2740, AS 2741, AS 2759, AS 3776, AS 3777, AS 4991 

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Cargo restraint systems and components Proof load Not applicable

AS 4344

1 to 1500 kN

Chain Proof load Not applicable

AS 2321; AS 4344

1 to 1500 kN,including on-site and mobile test rig testing (proof load)

Chain slings Breaking load; Proof load Not applicable

AS 3775.1; AS 3775.2 Section 7 

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Eye bolts; Eye hooks Proof load Not applicable

AS 2317.1; AS 3776; AS 3777

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Fibre rope slings Breaking load; Proof load Not applicable

AS 1380.1 (1998)

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Lifting and spreader beams; Man baskets Proof load Not applicable

AS 1418.17, AS 4991

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Lifting clutches for concrete elements Proof load Not applicable

AS 3850.1 clause 2.6

1 to 1500 kN

Synthetic fibre roundslings Breaking load; Proof load Not applicable

AS 4497

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Synthetic webbing flat slings Breaking load; Proof load Not applicable

AS 1353.1

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Wire rope slings Breaking load; Proof load Not applicable

AS 1666.1; AS 1666.2 Section 9 and Appendix C; AS 2759; AS 3569

1 to 1500 kN, including on-site and mobile test rig testing (proof load)

Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) Wire rope Detection of broken wires; Material loss Not applicable
Non-destructive testing (NDT) - Visual testing - During service life Wire rope Corrosion; Detection of broken wires; Fretting; Material loss; Mechanical damage and wear Visual testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.