Mettler Toledo Limited

Site

Melbourne Branch

Accreditation No.

11629

Site No.

11622

Date of Accreditation

29 Jun 1996

Address

Level 1, 191 Salmon Street
Port Melbourne, VIC 3207
Australia

au.mt.com

Contact

Mr Stuart Oakes P: +61 (03) 96445700

Availability

Services available to external clients

Scope of Accreditation

Melbourne Branch

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Mass - Determination of mass and calibration of weighing devices Mass standards Mass Gravimetric measurement against reference mass

Capability

with Calibration and Measurement Capability of - 

6 μg from 1 mg to 10 mg;
8 μg above 10 mg to 50 mg;
10 μg above 50 mg to 200 mg;
20 μg above 200 mg to 2 g;
30 μg above 2 g to 50 g;
0.1 mg above 50 g to 200 g;
0.6 mg above 200 g to 500 g;
0.7 mg above 500 g to 1 kg;
1 mg above 1 kg to 2 kg;
2 mg above 2 kg to 5 kg;
4 mg above 5 kg to 10 kg;
6 mg above 10 kg to 20 kg

Mass - Determination of mass and calibration of weighing devicesincluding on-site calibrations Industrial mass standards Mass Gravimetric measurement against reference mass OIML R111 and Internal Quality Procedure QP06b Weight Calibration

Capability

including on-site calibrations
with Calibration and Measurement Capability on
10 g from 50 kg to 500 kg
15 g above 500 kg to 1000 kg

Industrial weighing devices; Laboratory weighing devices; Precision laboratory balances Mass Gravimetric measurement against reference mass

Examination of Class III and Class IV weighing instruments to the procedures and requirements of the NMI NITP 6.1-6.4 National Instrument Test Procedures; EURAMET Calibration Guide 18

Capability

including on-site calibrations

with Calibration and Measurement Capability of - 

8 µg from 1 mg to 0.1 g
9.7 µg above 0.1 g to 0.2 g
13 µg above 0.2 g to 0.5 g
15 µg above 0.5 g to 1.0 g
19 µg above 1.0 g to 2.0 g
25 µg above 2.0 g to 5.0 g
31 µg above 5.0 g to 10.0 g
40 µg above 10 g to 20 g
50 µg above 20 g to 50 g
100 µg above 50 g to 100 g
200 µg above 100 g to 200 g
0.5 mg above 200 g to 500 g
5.2 mg above 500 g to 1000 g
10 mg above 1000 g to 2000 g
22 mg above 2000 g to 5000 g
0.05 g above 5 kg to 10 kg
0.1 g above 10 kg to 20 kg
0.13 g above 20 kg to 26 kg
0.15 g above 26 kg to 30 kg
0.2 g above 30 kg to 40 kg
5.0 g above 40 kg to 50 kg
6.0 g above 50 kg to 60 kg
6.4 g above 60 kg to 64 kg
10 g above 64 kg to 100 kg
12 g above 100 kg to 120 kg
15 g above 120 kg to 150 kg
20 g above 150 kg to 200 kg
68 g above 200 kg to 300 kg
110 g above 300 kg to 500 kg
140 g above 500 kg to 600 kg
220 g above 600 kg to 1000 kg
440 g above 1000 kg to 2000 kg
680 g above 2000 kg to 3000 kg

Volume and density - Laboratory volumetric glassware and measures Piston operated volumetric apparatus (POVA) Volume Gravimetric

 ISO 8655-6

Capability

with Calibration and Measurement Capability of - 

0.02 μL at 1 μL
0.03 μL above 1 μL to 2 μL
0.04 μL above 2 μL to 10 μL
0.05 μL above 10 μL to  20 μL
0.11 μL above 20 μL to  50 μL
0.16 μL above 50 μL to 100 μL
0.32 μL above 100 μL to 200 μL
0.48 μL above 200 μL to 300 μL
0.92 μL above 300 μL to 500 μL
1.6 μL above 500 μL to 1 mL
1.9 μL above 1 mL to 1.2 mL
3.0 μL above 1.2 mL to 2 mL
8.2 μL above 2 mL to 5 mL
17 μL above 5 mL to 10 mL
 33 μL above 10 mL to 20 mL

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.