Scope of Accreditation

Melbourne Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of geometric properties of structures and equipment Structures and assemblies Weight Not applicable

in-house methods WT026, WT 049

2 to 1,500 kN including tests in the field

Evaluation of load generating lifting appliances Cranes Proof load Not applicable

AS 1418.2

AS 4991

0.4 to 3,500 kN including tests in situ in the range 0.4 to 1,500 kN

Jibs and suspension equipment Proof load Not applicable AS 4991
AS 1418.3
0.4 to 3,500 kN including tests in situ in the range 0.4 to 1,500 kN
Serial and lever hoists Operational load Not applicable AS 1418.2 0.4 to 3,500 kN, including tests in situ in the range 0.4 to 1,500 kN
Evaluation of load handling, rigging and tensioning systems Bollards Breaking load; Proof load Not applicable

in-house method WT 029

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Chain Breaking load; Extension; Proof load Not applicable

AS 2321

AS 4797

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN,

Chain slings Breaking load; Proof load Not applicable

AS 3775.1

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN

Containers Proof load Not applicable

AS 4991

DNV-ST-E271 2.7-1

0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Eye bolts Breaking load; Proof load Not applicable

AS 2317.1

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN

Eye hooks; Shank hooks Breaking load; Extension; Proof load Not applicable AS 3777 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Fibre rope slings Breaking load; Proof load Not applicable

AS 1380.1:1998

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN
Gripping devices Breaking load; Extension; Proof load Not applicable AS 2076 Wire Rope Grips
Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Lifting assemblies Breaking load; Proof load Not applicable

AS 4991

in-house method WT 029

Proof load tests: 0.4 to 3,500 including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Lifting clutches for concrete elements Breaking load; Proof load Not applicable

AS 3850.1 Clause 2.6

Proof load: 0.4 to 1,500 kN including tests in the field

Breaking load: 2 to 3,500 kN

Lifting rings and links Breaking load; Extension; Proof load Not applicable AS 3776 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Nets (for unloading cargo) Proof load Not applicable AS 4991
DNV-ST-E271 2.7-1
Proof load tests: 0.4 to 3,500 including tests in the field 5 to 1,500 kN
Padeyes Breaking load; Proof load Not applicable in-house method WT-029 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Pallets Proof load Not applicable AS 4991
DNV-ST-E271 2.7-1

0.4 to 3,500 kN including tests in the field in the range 5 to 1,500 kN

Plate clamps Extension; Proof load Not applicable AS 4991 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Pulley blocks Proof load Not applicable AS 5227.1 0.4 to 3,500 kN, including tests in situ in the range 0.4 to 1,500 kN

Rigging screws and turnbuckles Breaking load; Extension; Proof load Not applicable AS 2319 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Shackles Breaking load; Extension; Proof load Not applicable AS 2741 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Sheave blocks Breaking load; Extension; Proof load Not applicable AS 2089 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Swivels Breaking load; Extension; Proof load Not applicable AS 2318
Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Synthetic fibre roundslings Breaking load; Proof load Not applicable

AS 4497

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN
Synthetic webbing flat slings Breaking load; Proof load Not applicable

AS 1353.1

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN
Thimbles for wire rope Breaking load; Extension; Proof load Not applicable AS 1138 Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Wedge type sockets Proof load Not applicable AS 2740 Proof load tests: 0.4 to 3,500 including tests in the field 5 to 1,500 kN
Breaking load tests: 2 to 3,500 kN
Wire rope Breaking load; Proof load Not applicable

AS 3569

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to ,1500 kN

Breaking load tests: 2 to 3,500 kN
Wire rope slings Breaking load; Proof load Not applicable

AS 1666.1

Proof load tests: 0.4 to 3,500 kN including tests in the field 5 to 1,500 kN

Breaking load tests: 2 to 3,500 kN,

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.