National Association of Testing Authorities, Australia
Scope of Accreditation
Metlogic Pty Ltd
Metlogic
Site
Metlogic Laboratory
Metlogic
Accreditation No.
20741
Site No.
24894
Date of Accreditation
07 Aug 2020
Contact
Mr Prabath Kamalasena P: +61 (02) 80045122
Availability
Services available to external clients
Scope of Accreditation
Metlogic Laboratory
ISO/IEC 17025 (2017)
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical measurement and test equipment | Electricity meters | Active energy; Reactive energy | Comparison with a reference standard | Accuracy requirement of single and polyphase electricity meters by the methods of - AS 1284.1, AS 1284.13, AS 62053.21, AS 62053.22, AS 62053.23, NITP 14 National Instrument Test Procedures for Utility Meters and NMI M 6-1 Active Energy Electricity Meters. Part 1: Metrological and Technical Requirements. Functional tests for no load and starting current by the methods of the above standards. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Watt-hour meters at 50 Hz across power factors 1.0 to 0.5 leading and lagging currentwith Calibration and Measurement Capability of - 600 µWh/VAh for currents from 10 mA to 50 mA and voltages from 63.5 V AC to 300 V AC 400 µWh/VAh for currents from 50 mA to 120 A and voltages from 63.5 V AC to 300 V AC Var-hour meters at 50 Hz across power factors 1.0 to 0.5 leading and lagging current with Calibration and Measurement Capability of - 400 µvarh/VAh for currents from 100 mA to 100 A from 63.5 V AC to 240 V AC Functional tests for no load and starting current. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20741
Site No.
24894
Print date
21 Nov 2024
END OF SCOPE