National Association of Testing Authorities, Australia
Scope of Accreditation
Monadelphous Engineering Pty Ltd
Site
Monadelphous Mackay Operations t/a Genco Pty Ltd
Accreditation No.
20989
Site No.
25228
Date of Accreditation
21 Mar 2022
Contact
Mr Anthony Prestipino
P: +61 (07) 48419131
Availability
Services available to external clients
Scope of Accreditation
Monadelphous Mackay Operations t/a Genco Pty Ltd
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Limitations |
---|---|---|---|---|
Non-destructive testing (NDT) - Material properties and internal integrity | Rolled or wrought steel products; Welded joints - Ferritic materials | Ultrasonic detection and characterisation of discontinuities | A-scan capability | |
Non-destructive testing (NDT) - Product profile and corrosion mapping | Metallic piping; Metallic plate; Metallic tubes - Ferromagnetic materials; Metallic tubes - Non-ferromagnetic materials | Ultrasonic material profiling and characterisation of material loss; Ultrasonic material thickness - Spot or grid measurements | A-scan - Manual; Thickness meter | |
Non-destructive testing (NDT) - Surface techniques | Metallic surfaces | Dye penetrant detection of discontinuities | Solvent removable; Water washable | |
Visual detection of discontinuities (prior to initial service) - Forgings; Visual detection of discontinuities (prior to initial service) - Rolled products; Visual detection of discontinuities (prior to initial service) - Welded joints | Visual examination | |||
Visual detection of discontinuities (during service life for defined service applications) - Forgings; Visual detection of discontinuities (during service life for defined service applications) - Rolled products; Visual detection of discontinuities (during service life for defined service applications) - Welded joints | Visual examination | |||
Electromagnetic detection and characterisation of discontinuities | Alternating current field measurement (ACFM) | |||
Magnetic particle detection of discontinuities | AC magnetic flow |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20989
Site No.
25228
Print date
16 May 2022
END OF SCOPE