Tex@Site Pty Ltd

Site

NATA Laboratory

Accreditation No.

15281

Site No.

15902

Date of Accreditation

16 Jul 2007

Address

17 Ceylon Street
Nunawading, VIC 3131
Australia

texatsite.com.au

Contact

Ms Poneh Nakhjiri P: +61 1300785935

Availability

Services available to external clients

Scope of Accreditation

NATA Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

20 μΩ/Ω + 5 μΩ up to 2 Ω; 

14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 

12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 

12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 

12 μΩ/Ω + 51 mΩ above  2 kΩ to 20 kΩ; 

16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 

17 μΩ/Ω + 14 Ω above  200 kΩ to 2 MΩ; 

49 μΩ/Ω + 590 Ω above  2 MΩ to 20 MΩ; 

170 μΩ/Ω + 19 kΩ above  20 MΩ to 200 MΩ; 

0.15% reading+ 2.6 MΩ above  200 MΩ to 2 GΩ; 

0.35% reading+ 47 MΩ above  2 GΩ to 20 GΩ;

0.75% reading+ 0.056%/GΩ above  20 GΩ to 90 GΩ

AC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

300 μV/V + 4.6 μV up to 200 mV and from 40 Hz to 100 Hz;
260 μV/V + 440 μV above 200 mV to 2 V and from 40 Hz to 100 Hz;
260 μV/V + 430 μV above 2 V to 20 V and from 40 Hz to 100 Hz;
260 μV/V + 430 μV above 20 V to 200 V and from 40 Hz to 100 Hz;
260 μV/V + 140 mV above 200 V to 1000 V and from 40 Hz to 100 Hz;
260 μV/V + 430 μV up to 200 mV and above 100 Hz to 2 kHz;
240 μV/V + 420 μV above 200 mV to 2 V and above 100 Hz to 2 kHZ;
200 μV/V + 400 μV above2 V to 20 V and above 100 Hz to 2 kHz;
230 μV/V + 380 μV above 20 V to 200 V and above 100 Hz to 2 kHz;
260 μV/V + 140 mV above 200 V to 1000 V and above 100 Hz to 2 kHz;
400 μV/V + 24 μV up to 200 mV and above 2 kHz to 10 kHz;
260 μV/V + 380 μV above 200 mV to 2 V and above 2 kHz to 10 kHz;
220 μV/V + 1.6 mV above 2 V to 20 V and above 2 kHZ to 10 kHZ;
220 μV/V + 16 mV above 20 V to 200 V and above 2 kHz to 10 kHz;
260 μV/V + 140 mV above 200 V to 1000 V and above 2 kHz to 10 kHz
AC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

780 μA/A + 68 nA from 30 μA to 200 μA and from 10 Hz to 10 kHz; 

460 μA/A + 470 nA above 200 μA to 2 mA and from 10 Hz to 10 kHz; 

460 μA/A + 4.7 μA above 2 mA to 20 mA and from 10 Hz to 10 kHz; 

690 μA/A + 47 μA above 20 mA to 200 mA and above 10 Hz to 10 kHz; 

0.11% reading + 1.1mA above 200 mA to 2 A and above 10 Hz to 2 kHz; 

0.13% reading + 8.2mA above 2 A to 20 A and above 10 Hz to 2 kHz;

0.13% reading + 1.1 mA above 200 mA to 2 A and above 2 kHz to 10 kHz; 

0.36% reading + 13 mA above 2 A to 20 A and above 2 kHz to 10 kHz

DC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

30 μA/A +11 nA up to  200 μA;
30 μA/A + 70 nA above 200 μA to 2 mA;
40 μA/A + 700 nA  above 2 mA to 20 mA;
100 μA/A + 20 μA above 20 mA to 200 mA;
390 μA/A + 530 μA above 200 mA to 2 A;
0.11% reading + 3.9 mA above 2 A to 20 A
DC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

17 μV/V + 6.3 μV up to 200 mV;
10 μV/V + 15 μV above 200 mV to 2 V;
10 μV/V + 120 μV above 2 V to 20 V; 

15 μV/V + 1.5 mV above 20 V to 200 V;
13 μV/V + 12 mV above 200 V to 1000 V 

DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Current clamps; Digital multimeters (DMM) AC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 


In the laboratory

710 μA/A + 69 nA up to 200 μA and from 20 Hz to 1 kHz; 

450 μA/A + 480 nA above 200 μA to 2 mA and from 20 Hz to 1 kHz; 

450 μA/A + 4.8 μA above 2 mA to 20 mA and from 20 Hz to 1 kHz; 

680 μA/A + 48 μA above 20 mA to 200 mA and from 20 Hz to 1 kHz; 

0.21% reading + 1.1 mA above 200 mA to 2 A and from 20 Hz to 500 Hz; 

0.22% reading + 8.3 mA above 2 A to 20 A and from 20 Hz to 500 Hz


For on site calibrations

0.18% reading + 550 nA from 20 μA to 200 μA and at 57 Hz; 

0.12% reading + 1.6 μA above 200 μA to 2 mA and at 57 Hz; 

0.12% reading + 16 μA above 2 mA to 20 mA and at 57 Hz; 

0.13% reading + 180 μA above 20 mA to 200 mA and at 57 Hz; 

0.26% reading + 3.5 mA above 200 mA to 2 A and at 57 Hz; 

0.38% reading+ 35 mA above 2 A to 20 A and at 57 Hz


Clamp on ammeters only both on site and at the laboratory

0.52% reading + 400 mA from 20 A to 100 A and at 57 Hz; 

0.63% reading + 2.4 A above 100 A to 1000 A and at 57 Hz

DC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 


In the laboratory

37 μA/A + 15 nA up to 200 μA; 

38 μA/A + 150 nA above 200 μA to 2 mA; 

43 μA/A + 1.5 μA above 2 mA to 20 mA; 

122 μA/A + 14 μA above 20 mA to 200 mA; 

460 μA/A + 97 μA above 200 mA to 2 A; 

0.11% reading + 3.9 mA above 2 A to 20 A


On site calibrations

230 μA/A + 31 nA from 20 μA to 200 μA; 

170 μA/A + 200 nA above 200 μA to 2 mA; 

150 μA/A + 1.9 μA above 2 mA to 20 mA; 

190 μA/A + 27 μA above 20 mA to 200 mA; 

610 μA/A + 710 μA above 200 mA to 2 A; 

0.16% reading+ 20 mA above 2 A to 20 A

Clamp on ammeters both on site and at the laboratory

0.48% reading + 180 mA from 20 A to 100 A;

0.53% reading + 1.3 A above100 A to 1000 A



Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

In the laboratory

20 μΩ/Ω + 7.2 μΩ up to 2 Ω; 

14 μΩ/Ω + 91 μΩ above 2 Ω to 20 Ω; 

12 μΩ/Ω + 810 μΩ above 20 Ω to 200 Ω; 

12 μΩ/Ω + 5.8 mΩ above 200 Ω to 2 kΩ; 

12 μΩ/Ω + 53 mΩ above 2 kΩ to 20 kΩ; 

16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 

17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 

49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 

170 μΩ/Ω + 20 kΩ above 19 MΩ to 200 MΩ; 

0.15% reading  + 2.6 MΩ above 200 MΩ to 2 GΩ; 

0.35% reading + 47 MΩ above 2 GΩ to 20 GΩ;


For on site calibrations

1.2% reading from 1 Ω to 10 Ω;

0.6% reading above 10 Ω to 100 Ω;

0.12% reading + 50 mΩ above 100 Ω to 1 kΩ;

0.12% reading + 500 mΩ above 1 kΩ to 10 kΩ;

0.12% reading + 5 Ω above 10 kΩ to 100 kΩ;

0.12% reading+ 50 Ω above 100 kΩ to 1MΩ;


Insulation resistance testers up to 1kV both on site and at the laboratory

1.9% reading from 10 MΩ to 100 MΩ;


Insulation resistance testers up to 5kV both on site and at the laboratory
2.6% reading from 100 MΩ to 200 MΩ;
4% reading above 200 MΩ to 300 MΩ;
3% reading above 300 MΩ to 400 MΩ;
2.7% reading above 400 MΩ to 500 MΩ;
2.5% reading above 500 MΩ to 1 GΩ;
3.5% reading above 1 GΩ to 2 GΩ;
5.5% reading above 2 GΩ to 3 GΩ;
3.7% reading above 3 GΩ to 4 GΩ;
3.5% reading above 4 GΩ to 7 GΩ;
3% reading above 7 GΩ to 10 GΩ;
10% reading above 10 GΩ to 50 GΩ;
15% reading above 50 GΩ to 99 GΩ

Digital multimeters (DMM); Voltmeters DC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

In the laboratory

17 μV/V + 6.3 μV up to 200 mV;

13 μV/V + 21 μV above 200 mV to 2 V;

13 μV/V + 47 μV above 2 V to 20 V;

17 μV/V + 580 μV above 20 V to 200 V;

18 μV/V + 8.7 mV above 200 V to 1000 V


For on site calibrations

Calibration and Measurement Capability of - 

230 μV/V + 7 μV from 2 mV to 20 mV;

43 μV/V + 16 μV above 20 mV to 200 mV;

19 μV/V + 130 μV above 200 mV to 2 V;

16 μV/V + 1.3 mV above 2 V to 20 V;

42 μV/V + 16 mV above 20 V to 200 V;

34 μV/V + 130 mV above 200 V to 1000 V


AC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

In the laboratory
280 μV/V + 23 μV up to 200 mV and from 40 Hz to 100 Hz;

260 μV/V + 440 μV above 200 mV to 2 V and from 40 Hz to 100 Hz;
260 μV/V + 430 μV above 2 V to 20 V and from 40 Hz to 100 Hz;
260 μV/V + 430 μV above 20 V to 200 V and from 40 Hz to 100 Hz;
260 μV/V + 140 mV above 200 V to 1000 V and from 40 Hz to 100 Hz;
400 μV/V + 2.3 μV up to 200 mV and above100 Hz to 2 kHz;
240 μV/V + 420 μV above 200 mV to 2 V and above 100 Hz to 2 kHz; 

200 μV/V + 400 μV above 2 V to 20 V and above 100 Hz to 2 kHz;
230 μV/V + 380 μV above 20 V to 200 V and above 100 Hz to 1 2 kHz;
260 μV/V + 140 mV above 200 V to 1000 V and above100 Hz to 1 2 kHz;
400 μV/V + 24 μV up to 200 mV and above 2 kHz to 10 kHz,
260 μV/V + 380 μV above 200 mV to 2 V and above 2 kHz to 10 kHz
220 μV/V + 1.6 mV above 2 V to 20 V and above 2 kHz to 10 kHz


For onsite calibrations

0.2% reading + 150 μV from 2 mV to 20 mV and at 57 Hz;

750 μV/V + 180 μV above 20 mV to 200 mV and at 57 Hz;

570 μV/V + 650 μV above 200 mV to 2 V and at 57 Hz;

570 μV/V + 6.8 mV above 2 V to 20 V and at 57 Hz;

910 μV/V + 68 mV above 20 V to 200 V and at 57 Hz;

0.12% reading + 340 mV above 200 V to 1000 V and at 57 Hz


DC and low frequency electrical metrology - Electrical standards Conductance boxes; Precision resistors; Resistance boxes Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of - 

20 μΩ/Ω + 5 μΩ up to 2 Ω; 

14 μΩ/Ω + 67 μΩ above 2 Ω to 20 Ω; 

12 μΩ/Ω + 570 μΩ above 20 Ω to 200 Ω; 

12 μΩ/Ω + 5.7 mΩ above 200 Ω to 2 kΩ; 

12 μΩ/Ω + 51 mΩ above 2 kΩ to 20 kΩ; 

16 μΩ/Ω + 1.4 Ω above 20 kΩ to 200 kΩ; 

17 μΩ/Ω + 14 Ω above 200 kΩ to 2 MΩ; 

49 μΩ/Ω + 590 Ω above 2 MΩ to 20 MΩ; 

170 μΩ/Ω + 19 kΩ above 20 MΩ to 200 MΩ;

0.15% reading  + 2.6 MΩ above 200 MΩ to 2 GΩ; 

0.35% reading + 47 MΩ above 2 GΩ to 20 GΩ; 

0.75% reading  + 0.056%/GΩ above 20 GΩ to 90 GΩ

Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges Gauge pressure By pressure calibrator

AS 1349 ;

MSA Test Method 1 ; 

MSA Test Method 2

Capability

Calibrations performed in the Laboratory and Mobile Vans

With Calibration and Measurement Capability of -

0.05% of reading or 0.01 kPa (whichever is greater) at -95 kPa to 70 MPa

Time and frequency metrology - Frequency, time and waveform measuring equipment Counters; Frequency meters Frequency Comparison with a reference standard

Capability

With Calibration and Measurement Capability of - 

in the laboratory calibration for Frequency
2.3 Hz/MHz from 10 Hz to 100 kHz;
onsite calibration of Frequency Meters

52 Hz/MHz from 10 Hz to 100 kHz


Tachometers Rotational speed Comparison with a reference standard

Capability

Including on site calibrations

With Calibration and Measurement Capability of-

52 rpm/1,000,000rpm + 1 rpm from 600 rpm to 60,000 rpm

Torque - Torque measuring and testing equipment Torque transducers Torque Gravimetric measurement with reference beam To the method of BS 7882

Capability

With Calibration and Measurement Capability of - 
0.4% of reading from 1.25 N.m to 25 N.m
0.1% of reading from 25 N.m to 1500 N.m
Torque wrenches Torque Comparison with a reference standard ASME B 107.300

Capability

Calibrations performed in the Laboratory and Mobile Vans

With Calibration and Measurement Capability of - 

1.0% of reading from 1.25 Nm to 1500 Nm

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.