Norditech Pty Ltd

Site

Norditech Laboratory

Accreditation No.

19660

Site No.

22824

Date of Accreditation

07 Oct 2015

Address

Unit 2/87 Station Rd
Seven Hills, NSW 2147
Australia

norditech.com.au

Contact

Mr Bruno Nourdine P: +61 0403248038

Availability

Services not available to external clients

Scope of Accreditation

Norditech Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Chemical metrology - Gas analysers Gas analysers; Mine safety and confined space equipment Concentration Direct measurement by certified reference material

in-house method TP.021 (including on site calibrations)

0-100%

Capability

With Calibration and Measurement Capability of-

GAS
DETECTOR TYPE
RANGE
UNCERTAINTY
AmmoniaIR0 to 100%
2.2 % of reading as % V/V or ppm
AmmoniaUV0 to 100%
2.2 % of reading as % V/V or ppm
Carbon dioxideIR0 to 100%2.2 % of reading as % V/V or ppm
Carbon dioxideElectrochemical
0 to 100%
2.2 % of reading as % V/V or ppm
Carbon monoxideElectrochemical0 to 5%
2.2 % of reading as % V/V or ppm
Carbon monoxideIR0 to 100%
2.2 % of reading as % V/V or ppm
ChlorineUV0 to 100%2.2 % of reading as % V/V or ppm
Hydrogen sulfideElectrochemical0 to 2000ppm
2.2 % of reading as part per 106 vol/vol (ppm)
Hydrogen sulfide
UV0 to 100%
2.2 % of reading as % V/V or ppm
MethaneCatalytic pellistor 
0 to 5%2.2 % of reading as % V/V or ppm
MethaneIR0 to 100%
2.2 % of reading as % V/V or ppm
OxygenElectrochemical0 to 100%
2.2 % of reading as % V/V or ppm
Oxygen
Paramagnetic0 to 100%2.2 % of reading as % V/V or ppm
Sulfur dioxideIR0 to 100%
2.2 % of reading as % V/V or ppm
Sulfur dioxideUV0 to 100%
2.2 % of reading as % V/V or ppm
Sulfur hexafluorideIR0 to 100%2.2 % of reading as % V/V or ppm

Flow metrology - Environmental flow measuring devices and systems Air sampling pumps and meters Flow rate Comparison with a reference meter

AS/NZS 3580.9.3, AS/NZS 3580.9.6

Capability

High volume air samplers 

With Calibration and Measurement Capability of-

7.3% of reading in the range 60 to 80 m3  /hour

ISO/IEC 17025 (2017)

Environment

Service Product Determinant Technique Procedure
Analysis for hydrocarbons Air - Ambient Methane; Non-methane hydrocarbons; Total hydrocarbons GC-FID

AS/NZS 3580.11.1 and in-house method TP.006

Analysis for physical and chemical characteristics Air - Ambient Suspended particulate matter - PM2.5 High volume gravimetric

AS/NZS 3580.9.14 and in-house methodTP.010

Sulfur dioxide Direct reading instrument

AS 3580.4.1 and in-house method TP.004

Suspended particulate matter - PM10 Beta attenuation monitors

AS/NZS 3580.9.11 and in-house method TP.008

Suspended particulate matter - Total High volume gravimetric

AS/NZS 3580.9.3 and in-house method TP.011

Suspended particulate matter - PM10 Tapered element oscillating microbalance (TEOM)

AS 3580.9.8 and in-house method TP.005

Suspended particulate matter - PM2.5 Beta attenuation monitors

AS/NZS 3580.9.12 and in-house method TP.007

Carbon monoxide Infrared (IR)

AS 3580.7.1 and in-house method TP.003

Suspended particulate matter - PM2.5 Tapered element oscillating microbalance (TEOM)

AS/NZS 3580.9.13 and in-house method TP.026

Suspended particulate matter - PM10 High volume gravimetric

AS/NZS 3580.9.6 and in-house method TP.009

Nitrogen - Oxidised Chemiluminescence

AS 3580.5.1 and in-house method TP.001

Air - Road tunnel ventilation stacks Particulate matter - PM10 Tapered element oscillating microbalance (TEOM) AS 3580.9.8 and in-house method TP.005
Carbon dioxide (CO2); Carbon monoxide; Nitrogen - Oxidised; Sulfur dioxide Differential optical absorption spectroscopy (DOAS) in-house method TP.028
Particulate matter - PM2.5 Tapered element oscillating microbalance (TEOM) AS/NZS 3580.9.13 and in-house method TP.026
Volatile organic compounds (VOCs) Gas chromatography (GC) AS/NZS 3580.11.1 and in-house method TP.006
Air - Road tunnels Carbon dioxide (CO2); Carbon monoxide; Nitric oxide; Nitrogen dioxide; Visibility Direct reading instrument AS/NZS 3580.18 and in-house method TP.017
Velocity Ultrasonic AS/NZS 3580.18 and in-house method TP.030
Meteorological monitoring Atmosphere Rainfall Rainfall gauge

AS/NZS 3580.14 and in-house method TP.013

Temperature Temperature probe

AS/NZS 3580.14 and in-house method TP.012

Relative humidity (RH) Hygrometer

AS/NZS 3580.14  and in-house method TP.014

Solar radiation Pyranometer

AS/NZS 3580.14 and in-house method TP.012

Wind direction; Wind speed - Horizontal Ultrasonic wind sensor

AS/NZS 3580.14  and in-house method TP.016

Sample collection Air - Ambient Not applicable Siting of air monitoring equipment

AS/NZS 3580.1.1

Not applicable Continuous flow analyser (CFA)

AS 3580.4.1, 5.1, .6.1, 7.1, 9.8; AS/NZS 9.11, 9.12, 9.13, 11.1 and in-house methods TP.001, .002, .003, .004, .005, .006, .007, .008, .026

Sample collection - Stack and emissions sampling Emissions - Stack Temperature To be determined in-house method TP.029
Flow rate To be determined in-house method TP.030

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.